Framed acoustic glazed movable wall.
Suitable for internal use.
Framed glass sliding stacking panel partition system.
Features and benefits:
Acoustic performance:
Color | Manufacturer guidanceAluminium frame powder coated to any standard RAL colour choice |
Finish | Powder-coated Guidance for specification option: Powder coated to any standard RAL colour choice |
Material | Glass Steel |
Shape | Rectangle |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Two year |
Uniclass | |
CAWS | K30/76 Glazing for relocatable partitions K30/480 Glazing for relocatable partitions L20/545 Sliding stacking panel partitions |
Performance | Sound reduction Rw 46 dB (laboratory tested).Guidance for specification option: Average achieved site insulation typically less than laboratory conditions. Sound reduction Rw 50 dB (laboratory tested).Guidance for specification option: Average achieved site insulation typically less than laboratory conditions. Manufacturer guidance
|
Operation | M – Manual.SE – Semi electric.Guidance for specification option: Semi electric available with slimmer frame; consult manufacturer for details. |
Dimensions (nominal) | |
Panel (average) | |
Width | Guidance for specification option: Up to 1200 mm (maximum). Insert requirements. |
Height | Guidance for specification option: Up to 4000 mm (maximum). Insert requirements. |
Thickness | 103 mm. |
Panels | |
Construction | NE (Standard panel).TE (Telescopic element).SE1 (Single inset pass door).SE2 (Double inset pass door).EE (Corner / junction panel).DT (Full height hinged pass door).Manufacturer guidance
|
Finish as delivered | Double glazed. |
Bunching | Single stack. Double stack. Bi-parting. |
Ceiling angle trim | Not required. Flush with underside of ceiling. Guidance for specification option: Two point suspension only. Exposed 20 mm from underside of ceiling. Guidance for specification option: Single point suspension only. Manufacturer guidanceCeiling track profile:
|
Partition assembly | As per manufacturer drawings SL – 111 and SL – 112. |
Track | TL 1 ‘E’ system. Guidance for specification option:
TL 2 ‘Za’ system. Guidance for specification option:
TL 3 ‘Zb’ system. Guidance for specification option:
TL 4 ‘Z’ system. Guidance for specification option:
TL 5 ‘K’ system. Guidance for specification option: For 90° movement of panels away from main track, twin point cross roller suspension. Manufacturer guidanceLayout. |
Track finish | White. Guidance for specification option: Standard. RAL. Guidance for specification option: Special order; insert requirement. |
Edges | Powder-coated, RAL. Guidance for specification option: Insert requirement. |
Fire performance | Non fire rated. |
Jambs | Standard: Width 80 mm. Telescopic jamb extended to 350 mm. |
Contains Red List materials | No |
Country of material origin | Netherlands |
Country of product manufacture | Netherlands |
Material | Glass Steel |
Recyclability | Metal parts can be separated and directed to material recycling. Theoretically, particle board can also be recycled by directing the panels to new production |