Verified by manufacturer 3 months ago
VETROFLAM 2S single glazing
Fire Resistant Glass
Developed specifically for integrity and radiation applications, which can be used for internal and external installations such as:
VETROFLAM is a fire protection glass. It can be installed monolithic, laminated or as double glazed units, particularly in overhead areas, where buildings are close to each other, or in largely glazed stairwells that have fire protection requirements.
VETROFLAM is particularly suitable to prevent the spread of fire in multi-storey buildings. For sloping and roof glazing applications, SGG VETROFLAM CLIMALIT and SGG VETROFLAM CLIMAPLUS can be combined with VETROFLAM STADIP. VETROFLAM products can be used in various frame and profile systems including steel and aluminium. The installation of VETROFLAM has to be installed in accordance with Vetrotech Saint-Gobain's guidelines. CE compliant.
Features and benefits:
Color | Clear |
Material | Glass Guidance for specification option: Fire resistant toughened safety glass. |
Shape | Other Guidance for specification option: Shapes available upon request. |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Five year Guidance for specification option: Minimum five years and extended depending on application |
Uniclass | |
CAWS | L40/510 Fire-resistant channel glazing – solid section channel L40/505 Fire-resistant tape/ Strip glazing L40/515 Fire-resistant channel glazing – plastics/ elastomeric channel L10/560 Glazed screen system L40/65 Fire-resistant tape/ Strip glazing L40/75 Fire-resistant channel glazing – solid section channel L40/80 Fire-resistant channel glazing – plastics/ elastomeric channel |
Laminate glass type | Single. |
Thickness | 6 mm. |
Body colour | Clear. |
Coating | |
Type | Heat reflective. |
Colour or effect | Clear.Obscure.Printed.Guidance for specification option: Insert requirements. |
Performance requirements | |
Fire resistance | |
Integrity | E30. |
Radiation | W30. |
Light | Contact Vetrotech for more information.Guidance for specification option: Consult manufacturer for details. |
Solar control | Contact Vetrotech for more information.Guidance for specification option: Consult manufacturer for details. |
Total shading coefficient | Contact Vetrotech for more information.Guidance for specification option: Consult manufacturer for details. |
Sound attenuation | Contact Vetrotech for more information.Guidance for specification option: Consult manufacturer for details. |
Impact resistance | Symmetrical 1(C)1 impact resistance (EN 12600). |
Thermal insulation | Contact Vetrotech for more information. Guidance for specification option: Consult manufacturer for details. |
Material | Glass Guidance for specification option: Fire resistant toughened safety glass. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 30 % Guidance for specification option: Glass should have a minimum recycled content of 30% |