Verified by manufacturer over a year ago
COLORBOND® Steel
Steel roofing and walling profile with flat pans.
Suitable for both roofing and walling applications.
AUSTRALIAN STANDARDS
Published load capacity data is derived from testing in accordance with:
Published Limit state capacities are suitable to determine structural adequacy and serviceability in accordance with:
Published installation guidelines align with AS 1562.1:2018 Design and Installation of sheet and wall cladding.
Fielders steel products comply with:
Prominence™ is a steel roofing and walling profile with flat pans. Its panels have underlap edges that allow it to be concealed pierced-fixed to its supports. Some of its features include:
Material | Steel. |
Shape | Rectangle |
Warranty description | Manufacturer guidanceCovered by BlueScope material warranties, subject to project assessment and terms and conditions. |
Uniclass | |
SpeedSpec | 07610 Roofing and Roof Plumbing 07462 Cladding External Walls |
NATSPEC National Classification System | 0436 Cladding – Profiled and Seamed Sheet Metal 0423 Roofing – Profiled Sheet Metal |
SpecPack | 07600 Metal Roofing, Siding and Roof Plumbing |
Standards | To AS 1397, AS/NZS 1365 and AS/NZS 2728.Guidance for specification option: Installation of the cladding should be in accordance with AS 1562.1 and HB 39. |
Structural grade | G300. |
Coating | |
Class | AM100. |
Size | |
Length | Manufacturer guidanceSheets are supplied custom cut to length to suit project requirements. Transportation limits apply. To address thermal expansion and contraction, recommended maximum sheet length is 15 m. Provide manufacturing tolerance of ±7 mm in length. |
Width | 265 mm.465 mm.Manufacturer guidanceRefers to profile width and coverage. Provide manufacturing tolerance of ±4 mm. |
Thickness | 0.55 mm.Guidance for specification option: Total Coated Thickness of 0.60 mm. 0.75 mm.Guidance for specification option: Total Coated Thickness of 0.80 mm. Manufacturer guidanceRefers to Base Metal Thickness or BMT. Indicated Total Coated Thickness (TCT) is based on standard COLORBOND®, single-sided material. |
Finish | |
Applied | Painted. |
Colour | Basalt. Classic Cream. Cottage Green. Cove. Deep Ocean. |
Material | COLORBOND® steel. |
Cyclonic performance | To AS 1170.2:2011, AS 4040.1-1992, AS 4040.3-1992, AS 4055:2012. |
Thermal expansion | 2.9 mm average per 5.0 m. Manufacturer guidanceComputed at 50° C change. |
Frame or support | Plywood. Guidance for specification option: Plywood backing should be 15 mm CD grade ply. This is to be supported with purlins of minimum 1.00 mm BMT G550, with maximum spans of 600 mm. Affix with 10g-12 x 25 mm Wafer Head Type 17 screw and M5-15 x 1.2 galvanised steel washer. At rib edge, use multigrip rivets or equivalent to stitch ribs at end of sheet. Steel Batten. Guidance for specification option: Steel battens should be 40 mm x 0.75 mm BMT G550, with maximum spans of 450 mm. This is to be supported with purlins of minimum 1.00 mm BMT G550, with maximum spans of 1200 mm. Affix with 10g-16 x 16 mm Wafer Tek screw and M5-15 x 1.2 galvanised steel washer. At rib edge, use multigrip rivets or equivalent to stitch ribs at end of sheet. Timber. Guidance for specification option: Affix with 10g-12 x 45 mm Wafer Head Type 17 screw and M5-15 x 1.2 galvanised steel washer. At rib edge, use multigrip rivets or equivalent to stitch ribs at end of sheet. KingFlor® KF40®. Guidance for specification option: For resistance to wind-borne debris, KF40 backing is required. KF40 should be 0.75 mm BMT, to be supported by wall girts of 1200 mm maximum spans. If panels are to be installed vertically, steel battens with 1200 mm maximum spans should be added. Affix with 10g-16 x 16 mm Wafer Head Tek screw and M5-15 x 1.2 mm rounded washer. Manufacturer guidanceRefers to recommended substrate and fasteners if product is to be installed without insulation. |
Mass | 5.92 – 7.02 kg/m² (0.55 mm BMT). 6.88 – 9.21 kg/m² (0.75 mm BMT). |
Insulation | Manufacturer guidanceWhen insulation thickness up to 50 mm are installed, screws may need to be increased in number depending on insulation thickness and density. When insulation is required, Fielders® recommends the use of a thermal spacer. |
Installation | Concealed pierced-fixed. Guidance for specification option: Prominence™ is concealed pierced-fixed to either plywood or batten supports. Screws can be placed through slotted holes or directly through the sheet. |
Country of material origin | Australia |
Country of product manufacture | Australia |
Recyclability | 100% Recyclable. |