Verified by manufacturer over a year ago
COLORBOND® Ultra Steel
Roofing and walling profile with two pans. Available in WA only.
Suitable for both roofing and walling applications. Available in Western Australia only. For availability in other regions, contact local manufacturer.
AUSTRALIAN STANDARDS
Published load capacity data is derived from testing in accordance with:
Published Limit state capacities are suitable to determine structural adequacy and serviceability in accordance with:
Published installation guidelines align with AS 1562.1:2018 Design and Installation of sheet and wall cladding.
Fielders steel products comply with:
Shadowline® WA is a roofing and walling profile with two pans. Its panels can be button punched or pierced-fixed, depending on desired use. Some of its features include:
Material | Steel. |
Shape | Rectangle |
Warranty description | Manufacturer guidanceCovered by BlueScope material warranties, subject to project assessment and terms and conditions. |
Uniclass | |
SpeedSpec | 07610 Roofing and Roof Plumbing 07462 Cladding External Walls |
NATSPEC National Classification System | 0436 Cladding – Profiled and Seamed Sheet Metal 0423 Roofing – Profiled Sheet Metal |
SpecPack | 07600 Metal Roofing, Siding and Roof Plumbing |
Standards | To AS 1397 and AS/NZS 2728. |
Grade | G300. |
Coating class | AM150. |
Base Metal thickness (BMT) | 0.70 mm.Guidance for specification option: Total Coated Thickness of 0.75 mm. Manufacturer guidanceIndicated Total Coated Thickness (TCT) is based on standard COLORBOND®, single-sided material. |
Profile | |
Form | Standing seam profile. |
Height | 48 mm. |
Cover width | 305 mm.Manufacturer guidanceProvide manufacturing tolerance of ±5 mm. |
Colour | Dune.Monument.Surfmist.Wallaby.Windspray.Woodland Grey.Manufacturer guidanceColours are limited to certain finishes. |
Finish | Painted. |
Solar absorptance value (maximum) | 0.32–0.73.Manufacturer guidanceValue is dependant on colour. Contact manufacturer for further assistance. |
Material | COLORBOND® steel. |
Length | Manufacturer guidanceSheets are supplied custom cut to length to suit project requirements. Transportation limits apply. To address thermal expansion and contraction, recommended maximum sheet lengths are 24 m for roofing and 15 m for walling applications. Where lengths exceed 24 m, step joints or concealed decks are recommended. Provide manufacturing tolerances of ±10 mm in length and ±5 mm in width. |
Span | 450 mm. 600 mm. 900 mm. 1200 mm. 1500 mm. Manufacturer guidanceVaries depending on building height, profile thickness and span type. Maximum recommended spans for buildings less than 5 m high are:
Maximum recommended spans for buildings 5 to 10 m high are:
|
Cyclonic performance | To AS/NZS 1170.2:2011 and AS 4040.1-1992. |
Thermal expansion | 2.9 mm average per 5.0 m. Manufacturer guidanceComputed at 50° C change. |
Frame or support | Steel (1.0 to 3.5 mm). Guidance for specification option:
Timber Hardwood. Guidance for specification option:
Timber Softwood. Guidance for specification option:
Steel Battens (0.55 to 1.0 mm). Guidance for specification option:
Manufacturer guidanceRefers to recommended supports and fasteners if product is to be installed without insulation. |
Mass | 9.53 kg/m² (COLORBOND® steel). 9.36 kg/m² (ZINCALUME® steel). |
Insulation | Manufacturer guidanceWhen insulation thickness up to 50 mm are installed, screws may need to be increased in number depending on insulation thickness and density. When insulation is required, Fielders® recommends the use of a thermal spacer. |
Installation | Button punched. Pierced-fixed (for walling installations only). |
Country of material origin | Australia |
Country of product manufacture | Australia |
Recyclability | 100% Recyclable. |