Verified by manufacturer over a year ago
Heritage Galvanised Steel
Walling and short span roofing profile.
Suitable for both commercial or domestic use.
AUSTRALIAN STANDARDS
Published load capacity data is derived from testing in accordance with:
Published Limit state capacities are suitable to determine structural adequacy and serviceability in accordance with:
Published installation guidelines align with AS 1562.1:2018 Design and Installation of sheet and wall cladding.
Fielders steel products comply with:
TL-5™ Cyclonic is a walling and short span roofing profile with specially designed capillary grooves. Some of its features include:
Material | Steel. |
Shape | Trapezoid. |
Warranty description | Manufacturer guidanceCovered by BlueScope material warranties, subject to project assessment and terms and conditions. |
Uniclass | |
SpeedSpec | 07610 Roofing and Roof Plumbing 07462 Cladding External Walls |
NATSPEC National Classification System | 0436 Cladding – Profiled and Seamed Sheet Metal 0423 Roofing – Profiled Sheet Metal |
SpecPack | 07600 Metal Roofing, Siding and Roof Plumbing |
Standards | To AS 1397 and AS/NZS 2728.Guidance for specification option: Installation of the cladding should be in accordance with AS 1562.1 and HB 39. |
Grade | G550. |
Coating class | Z600. |
Base Metal thickness (BMT) | 0.35 mm.Guidance for specification option: Total Coated Thickness of 0.40 mm. 0.42 mm.Guidance for specification option: Total Coated Thickness of 0.47 mm. 0.48 mm.Guidance for specification option: Total Coated Thickness of 0.53 mm. Manufacturer guidanceIndicated Total Coated Thickness (TCT) is based on standard COLORBOND®, single-sided material. |
Profile | |
Form | Trapezoidal. |
Height | 28 mm.Manufacturer guidanceRefers to rib height. |
Cover width | 762 mm.Manufacturer guidanceProvide manufacturing tolerance of ±4 mm. |
Colour | Standard galvanised steel colour. |
Finish | Zinc-coated. |
Material | Galvanised steel. |
Length | Manufacturer guidanceSheets are supplied custom cut to length to suit project requirements. Transportation limits apply. To address thermal expansion and contraction, the recommended maximum sheet length is 24 m. Where lengths exceed 24 m, step joints or concealed decks are recommended. Provide manufacturing tolerance of ±7 mm in length. |
Span | 900 mm. 1200 mm. 1500 mm. 1800 mm. 2100 mm. Manufacturer guidanceRefers to maximum allowable spans per wind region. These vary depending on building height, profile thickness and span type. Maximum recommended roof spans for buildings less than 5 m high are:
Maximum recommended spans for buildings 5 to 10 m high are:
|
Cyclonic performance | To AS 1170.2-2011 and AS 4040.0-1992. |
Thermal expansion | 2.9 mm average per 5.0 m. Manufacturer guidanceComputed at 50° C change. |
Frame or support | Steel (1.0 to 3.5 mm). Guidance for specification option:
Manufacturer guidanceRefers to recommended fixing supports and fasteners. Use three fasteners per sheet. |
Mass | 3.60 – 3.68 kg/m² (0.35 mm BMT). 4.34 – 4.42 kg/m² (0.42 mm BMT). 4.87 – 4.96 kg/m² (0.48 mm BMT). |
Insulation | Manufacturer guidanceWhen insulation thickness up to 50 mm are installed, screws may need to be increased in number depending on insulation thickness and density. For insulation thicknesses greater than 50 mm, Fielders® recommends the use of a thermal spacer. |
Installation | Pierced-fixed. |
Ancillary components | Masonry Parapet Side Wall (Low or High). Apron Flashings. Overflashing. Headwall Apron Flashing. Soaker Gutter. Manufacturer guidanceOptionally available. Contact manufacturer for further details. |
Country of material origin | Australia |
Country of product manufacture | Australia |
Recyclability | 100% Recyclable. |