NBS Source
I'm a manufacturer

Compare variants

Thermally Broken Steel Fire-resistant Door - Janisol C4
Thermally Broken Steel Fire-resistant Door - Janisol C4
Thermally Broken Steel Fire-resistant Door - Janisol C4

Verified 4 days ago

Schueco UK Ltd

Verified 4 days ago

Schueco UK Ltd

Verified 4 days ago

Schueco UK Ltd
Summary
Fire door for demanding security requirements.
Digital objects
-
-
Finish
Galvanized, Natural, Powder-coated, Enamelled
-
-
Material
Steel
-
-
Width
Bespoke
-
-
Height
Bespoke
-
-

Specification

Standard
To EN 16034.
-
-
Third-party certification
EPD; CE Marking.
-
-
Configuration
Double leaf inward opening.
-
-
Performance
-
-
-
Fire resistance
-
-
-
Insulation
To EN 13501-2, EI60., To EN 13501-2, EI90.
-
-
Smoke leakage
To EN 1634-3, S200.
-
-
Strength and durability
To BS EN 1192, Class 4; to EN 1191, Class 6.
-
-
Frame
-
-
-
Material
Steel.
-
-
Finish
-
-
-
Coating
Uncoated., Strip-galvanized., Powder coated., Stove enamelled.
-
-
Door leaf
-
-
-
Thickness
70 mm.
-
-
Core
Manufacturer's standard.
-
-
Panel details
Manufacturer's standard.
-
-
Material
Steel.
-
-
Finish
-
-
-
Coating
As Frame.
-
-
Texture
Manufacturer's standard.
-
-
External colour
As Frame.
-
-
Internal colour
As External.
-
-
Film thickness (minimum)
Manufacturer's standard.
-
-
Architraves
-
-
-
Material
Steel.
-
-
Finish
As Frame.
-
-

Additional properties

Resistance to wind load
To EN 12210, Class 4.
-
-
Watertightness
To EN 12208, 4A.
-
-
Air permeability
To EN 12207, Class 4.
-
-
Operating forces
To EN 12217, Class 2.
-
-

Sustainability data

Country of material origin
United Kingdom
-
-
Recycled content
23 %
-
-