NBS Source
I'm a manufacturer
Delta Membrane Systems Ltd

Delta Membrane Systems Ltd

Delta Membranes

+44 (0)1992 523523 Website

Sort by:

Showing 1-7 of 7

RIBA CPD logo
Cold Liquid Applied Waterproofing

Cold Liquid Applied Waterproofing

Delta Membrane Systems Ltd

This CPD presentation introduces Architects/Designers/Specifiers with a technical insight to approaches to structural waterproofing utilising cold liquid applied systems which are available within the construction industry. The presentation focuses on creating a waterproofing solution which meets British Standard BS 8102:2022, the code of practice for the waterproofing industry and ensuring designs conform. Topics include: the importance of specifying a suitable continuous waterproofing solution, design considerations, build ups suitable for cold applied systems and the associated components and detailing for this. The seminar concludes with some helpful guidance. By the end of the CPD you should have a greater understanding of: - The different usages of below ground structures - The importance of BS 8102:2022 and how to design waterproofing system which meets requirements - The Tools and techniques for understanding types of waterproofing systems - Why waterproofing failures happen and how to avoid them with correct Product Specification - Design Principles.
Book CPD
RIBA CPD logo
Flood Resilience

Flood Resilience

Delta Membrane Systems Ltd

The aim of this CPD presentation is to provide architects and designers with a deeper understanding of the concepts of flood resistance, resilience and recoverability. Exploring flood resilience, resistance and recoverability and the use of technologies which have been used historically in below ground structural waterproofing in a variety of different situations from domestic to commercial structures. In addition, the CPD covers important insights for architects and designers when designing a robust flood resilient solution. It will help you to understand the following topics: - What flood resilience is - Flood risk management - Assessments of flood water into buildings in relation to British Standard BS85500: 2015 - Flood resilience, resistance and recoverability - Design principles - Solutions available This CPD can be delivered to you live and remotely.
Book CPD
RIBA CPD logo
Structural Waterproofing for Podium Decks and Buried Roofs

Structural Waterproofing for Podium Decks and Buried Roofs

Delta Membrane Systems Ltd

There are many common pitfalls when it comes to designing a waterproofing system for podium decks, buried roofs, balconies and terraces. These complex constructions require an in-depth knowledge of construction along with structural waterproofing. From differential movement to drainage, both should be key considerations as part of the building design process. The aim of this CPD presentation is to provide Architects/Designers and Specifiers with a technical approach to the concepts of successful design. By the end of the CPD you should have a greater understanding of: - What Podium Decks, Buried Roofs and Terraces are and their uses, along with types of structures and approaches to these - Regulations and requirements - Why waterproofing systems are specified - The importance of drainage consideration and components of waterproofing and drainage systems - Design principles and causes of failed systems when design principles are not applied.
Book CPD
RIBA CPD logo
Water and Water Vapour Management in Sub and Super-Structure Applications

Water and Water Vapour Management in Sub and Super-Structure Applications

Delta Membrane Systems Ltd

Experience has shown that specifiers and designers could be better informed about the practical operation of drained cavity membranes and particularly the need for mechanical drainage - sump and pump - requirements to complete the installation. This seminar describes the use of drainage membranes in new build and refurbishment applications. It also illustrates how such membranes can be used to reduce the ground water pressure acting upon a basement structure.
Book CPD
RIBA CPD logo
Waterproofing - The use of concrete combinations Type A, B and C Systems.

Waterproofing - The use of concrete combinations Type A, B and C Systems.

Delta Membrane Systems Ltd

This CPD presentation is designed to equip Architects, Designers, and Specifiers with a comprehensive understanding of the factors a waterproofing design specialist considers, to formulate a robust solution that aligns with the standards of BS 8102:2022 and BS 8500-1:2023. The seminar is crafted to educate, enrich, and engage delegates, focusing on topics like below ground waterproofing, combined waterproofing (two systems), product compatibility, and how to determine the right waterproofing solution for a structure. The seminar concludes with an interactive Q&A session, allowing attendees to address their queries directly to the presenter. By the end of this CPD delegates ought to: 1. Be able to identify different types of waterproofing and their placement. 2. Be able to identify the relationships between codes and standards and how waterproofing systems fit into this. 3. Know more about preventing water damage and ensuring the longevity of structures. 4. Know that where applying 2 forms of waterproofing solution, an understanding of these, offering different property characteristics. 5. Have the tools, systems, and information needed to solve problems, and create innovative solutions.
Book CPD
RIBA CPD logo
Waterproofing Below Ground Structures to BS 8102:2022

Waterproofing Below Ground Structures to BS 8102:2022

Delta Membrane Systems Ltd

This CPD presentation introduces Architects/Designers/Specifiers with a technical insight into approaches to structural waterproofing. Introducing designers with the elements and considerations a waterproofing design specialist will use to develop a robust waterproofing solution that meets the criteria of BS 8102:2022, the British Standard for the waterproofing industry. Topics include: What are Types A, B & C (the different forms of structural waterproofing systems available in the UK market) and how to achieve the environmental grades outlined within British Standard 8102:2022. A focus on how combination waterproofing systems are specified in below-ground structures in order to achieve the desired environmental grade, along with remedial approaches to design out risk. By the end of the CPD you should have a greater understanding of: - The importance of BS 8102:2022 and how to design waterproofing system which meets requirements - The tools and techniques for understanding types of waterproofing systems - Types A, B & C - Combination waterproofing - The techniques for maintaining the continuity of the waterproofing system - Design Principles.
Book CPD
RIBA CPD logo
Waterproofing Existing Basements

Waterproofing Existing Basements

Delta Membrane Systems Ltd

This CPD aims provide a technical insight into structural waterproofing existing basements and cellars. It touches on client requirements when designing and specifying waterproofing systems whilst discussing the levels of protection which can be achieved, along with the features, benefits and options available for a robust solution. The presentation focuses on a solution which meets British Standard 8102:2009, the code of practice for the waterproofing industry and ensures designs conform as a minimum. Topics covered include how different levels of protection can be achieved, why some waterproofing systems fail, and what can be done to remedy failed systems whilst remaining compliant with standards. By the end of the CPD you should have a greater understanding of: - How to recognise different usages of basements and cellars and that different waterproofing systems solve different problems - The importance of BS 8102:2009 and how to design waterproofing systems which meet requirements - Tools and techniques for understanding types of waterproofing systems - Why waterproofing failures happen and how to avoid them with correct Product Specification - Design Principles
Book CPD

Showing 1-7 of 7