NBS Source
I'm a manufacturer
NCC – Emseal Movement Joints

NCC – Emseal Movement Joints

Emseal - Watertight by Design

+44 (0) 1257 266696 Website

Sort by:

Showing 1-17 of 17

Sponsored
Emseal Colorseal VHE - CE Declaration of Performance

Emseal Colorseal VHE - CE Declaration of Performance

NCC – Emseal Movement Joints

Areas of use: Linear Joint & Gap Sealing. Declared Essential Characteristics Performance report: Reaction to Fire: Resistance to Fire Water permeability Air permeability Airborne sound insulation Movement Capability 100% (+/- 50%) Durability and serviceability
Sponsored
Emseal Colorseal VHE Product Data Sheet

Emseal Colorseal VHE Product Data Sheet

NCC – Emseal Movement Joints

Typically, the Emseal Colorseal system is used in external facades and parapet walls for example, where it is suitable for both single and double-sided wide and/or high movement joint sealing applications, meaning it is suitable as a primary and/or secondary joint sealing solution, according to structural design and exposure requirements. In terms of joint installation and performance, the Emseal Colorseal system is extremely useful to designers because with no invasive mechanical fixings, it provides a watertight sealed joint, with considerable joint movement capability of up to 100%, which will accommodate up to +/- 50% movement of the joint width e.g. plus (+) or minus (-) 50mm for a 100mm wide vertical expansion joint.
Sponsored
Emseal DSM System Installation Guide

Emseal DSM System Installation Guide

NCC – Emseal Movement Joints

Guide to the successful installation of the Emseal DSM System for sealing wide & high movement deck joints
Sponsored
Emseal DSM System Technical Data Sheet

Emseal DSM System Technical Data Sheet

NCC – Emseal Movement Joints

Emshield® DSM System has a long and well-proven track record of many years in sealing horizontal plane and below-grade joints. The Emseal DSM System is comprised of factory prepared and precompressed, silicone and impregnated foam hybrid profile that is installed into field-applied structural epoxy adhesive on the joint faces, with the silicone bellows locked to the joint faces with a silicone sealant band. The resulting product is suitable for a wide range of applications to seal horizontal joints in many different types of structure. The composition gives advantages for applications where traditional asphalt and wax-based products do not work well, such as under exposed conditions of thermal shock (leading to rapid opening and closing of joints during large temperature swings).
Sponsored
Emseal QuietJoint® - Installation Guide

Emseal QuietJoint® - Installation Guide

NCC – Emseal Movement Joints

Sponsored
Emseal QuietJoint® - TDS

Emseal QuietJoint® - TDS

NCC – Emseal Movement Joints

Sponsored
Emseal RoofJoint PDS - Roof Expansion Joint

Emseal RoofJoint PDS - Roof Expansion Joint

NCC – Emseal Movement Joints

Emseal RoofJoint is a patented dual-seal, double-flanged, extruded thermoplastic rubber system for sealing expansion joints in roofs, as well as plaza assemblies, green and vegetative roofs. Watertightness is achieved through positive (welded or bonded) integration with the roofing membrane and a purpose-designed system for transitioning between the joint in the roof and joints in walls.
Sponsored
Emseal Roofjoint-Installation Guide

Emseal Roofjoint-Installation Guide

NCC – Emseal Movement Joints

Emseal RoofJoint - A guide to installation on site
Sponsored
Emseal RoofJoint-Safety Data Sheet

Emseal RoofJoint-Safety Data Sheet

NCC – Emseal Movement Joints

MSDS
Sponsored
Emseal SJS System Installation Guide

Emseal SJS System Installation Guide

NCC – Emseal Movement Joints

The Emseal SJS System is a joint filling and sealing system with an integral trafficable coverplate. The system is securely installed by structural bonding so that it is firmly anchored to the joint faces of structural expansion joint, and seals the gaps between flat, level adjacent slabs. Installation will normally bring the top surface of the SJS proud of the finished deck level by the thickness of the coverplate, or it can be slightly recessed, where this installation option has been specified.
Sponsored
Emseal SJS System technical Data Sheet

Emseal SJS System technical Data Sheet

NCC – Emseal Movement Joints

The Emseal SJS System (Seismic Joint Sealing) is a high performance, horizontal, watertight, wide and / or high movement, expansion joint sealing system with an integral protective cover plate. It is the ideal solution for sealing wide and / or high movement joints in parking areas for vehicular traffic, with the range including systems for all types of traffic from pedestrians to HGV’s, in traffic, parking and hard standing areas. The Emseal SJS System can also accommodate up to 100% (+/- 50%) movement and is normally used for joints from 100 to 400mm wide, though bespoke systems for joints from 50mm to more than 450mm have been produced.
Sponsored
Emseal SJS Systems - Maintenance Sheet

Emseal SJS Systems - Maintenance Sheet

NCC – Emseal Movement Joints

Inspection and Maintenance of Emseal SJS Systems
Sponsored
Emshield DFR / WFR CE - CE Declaration of Performance

Emshield DFR / WFR CE - CE Declaration of Performance

NCC – Emseal Movement Joints

The intended use of fire rated movement joint sealants EMSHIELDWFR and DFR is to reinstate the fire resistance performance of separating building elements where they are interrupted. EMSHIELD DFR is used as a joint seal in a floor or as horizontal joint abutting a floor, ceiling or roof (configurations) A and D in figure 1 in EA 350141-00-1106). EMSHIELD WFR is used as a vertical joint seal in a wall (configuration B in figure 1 in EAD 350141-00-1106) Declared Essential Characteristics Performance report Reaction to Fire: Resistance to Fire Water permeability Air permeability Airborne sound insulation Movement Capability 100% (+/- 50%) Durability and serviceability
Sponsored
Emshield DFR / WFR CE Installation Guide

Emshield DFR / WFR CE Installation Guide

NCC – Emseal Movement Joints

Vertical and Horizontal installations use the same methods. The illustrations of this installation guide are horizontal, but the same methods should be applied for vertical applications.
Sponsored
Emshield DFR-WFR CE Product Data Sheet

Emshield DFR-WFR CE Product Data Sheet

NCC – Emseal Movement Joints

Fire Resistant (CE Registered) Floor & Wall Movement Joint Sealing System -Product Data Sheet
Sponsored
NCC-Emseal-BEJS Bridge Joint Brochure

NCC-Emseal-BEJS Bridge Joint Brochure

NCC – Emseal Movement Joints

Information and Selection Guide for Emseal BEJS - Bridge Expansion Joint System, including installation Guidelines and useful advice.
Sponsored
QuietJoint® R-Value Test

QuietJoint® R-Value Test

NCC – Emseal Movement Joints

Showing 1-17 of 17