Verified by manufacturer 5 months ago
Apollo ATI natural flap roof ventilator
Certificate of constancy of performance
Certificate type
Natural smoke extract and day-to-day ventilator with or without weathered ventilation facility.
Natural smoke extraction and day-to-day ventilation.
Suitable for most kinds of industrial buildings and is usually installed on building rooftops. May be installed either onto roofs or into barrel vault daylighting systems.
Natural flap ventilators providing both smoke and day-to-day ventilation. It allows extract ventilation for most kinds of industrial buildings and is usually installed on building rooftops.
Apollo ATI includes weathered ventilation via longitudinal side flaps.
Features and benefits:
Color | Silver Other |
Finish | Mill |
Material | Steel Aluminium |
Shape | Rectangle Square |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | L10/47 Roof ventilators L10/490 Roof ventilators |
Product range |
Standard | To BS EN 12101-2. |
Opening type | B. |
Mounting | Roof mounted, onto curb.Roof mounted, onto glazing.Onto curtain walling.Roof mounted, onto roof sheeting. |
Aerodynamic free area | Maximum: 5.7 m². |
Reliability classification | Re 1000.Guidance for specification option: 10 000 cycles. |
Snow load classification | Manufacturer's standard.Guidance for specification option: Up to 5700 N/m² (electric), 1500 N/m² (pneumatic). |
Low ambient temperature classification | T (-15). |
Wind load classification | WL 1500.Guidance for specification option: Aerodynamic coefficient (Cv): Up to 0.68. |
Resistance to heat classification | B300. |
Arrangement | Flap. |
Dimensions | |
Length | Manufacturer guidanceInsert requirements, 1000–3000 mm (1 mm increments). |
Width | Manufacturer guidanceInsert requirements, 1000–1900 mm (1 mm increments). |
Height | Manufacturer's standard. |
Controls | Pneumatic cylinders with integral spring return.Guidance for specification option: Snow load: Up to 1500 N/m². 24 V electric actuators.Guidance for specification option: Snow load: Up to 5700 N/m². Manual. |
Initiation | Manufacturer's standard. |
Materials | |
Ventilator | |
Frame | Corrosion-resistant aluminium alloy grade 3005 in accordance with EN 573-3.Guidance for specification option: With stainless steel fixings. |
Louvres | As arrangement. |
Glazing | 16 mm clear polycarbonate lid.Guidance for specification option: Seven skins, six chambers 16 mm opaque polycarbonate lid.Guidance for specification option: Seven skins, six chambers 16 mm grey (non-light transmitting) polycarbonate lid.Guidance for specification option: Seven skins, six chambers 10 mm clear polycarbonate with 6 mm solid external sheet lid.Guidance for specification option: Single chamber. 10 mm opaque polycarbonate with 6 mm solid external sheet lid.Guidance for specification option: Single chamber. 20 mm double-skin insulated aluminium infill panel lid.32 mm clear polycarbonate lid.Guidance for specification option: 8–10 chambers, U-value of 1.1–1.3 W/m²K. 32 mm opaque polycarbonate lid.Guidance for specification option: 8–10 chambers, U-value of 1.1–1.3 W/m²K. |
Finish | Mill finish.Polyester powder coated.Guidance for specification option: Standard film thickness: 75 µm. |
Colour | Silver.Guidance for specification option: Standard for mill finish. RAL.Guidance for specification option: Many colour options available; consult manufacturer for details and insert requirements. |
Integral upstands | |
Material | Double-skin aluminium (insulated).Single-skin aluminium.Manufacturer guidanceConsult manufacturer for insulation options. |
Finish | To match frame.Mill finish.Polyester powder coated.Guidance for specification option: Standard film thickness: 75 µm. |
Colour | To match frame.Silver.Guidance for specification option: Standard for mill finish. RAL.Guidance for specification option: Many colour options available; consult manufacturer for details and insert requirements. |
Seals | Manufacturer's standard.Guidance for specification option: Rubber; used to reduce air leakage when closed. |
Fixing | Onto curb. Onto glazing. Onto curtain walling. Onto roof sheeting. |
Locking | Double. Failsafe closed. Failsafe open. |
U-value | Manufacturer's standard. Guidance for specification option: As low as 1.5 W/m²K; consult manufacturer for details. |
Resistance to fire | E. Guidance for specification option: To EN 13501-1. |
Air permeability | Class 3. Guidance for specification option: To EN 12207:2000. |
Sound insulation | 28 dB Rw. |