Application

  • Suitable for the thermal insulation of buildings.
  • The product is also suitable for use as thermal insulation filling all kinds of elements in the refrigeration industry (furniture refrigerators, showcases, displays), in the heat (electric water heaters, accumulators, tanks) and on boats.

Description

A pour-in-place system to be injected in cavity walls in construction. The system can be processed using high- or low-pressure machines or manually.


Features and benefits:

  • The product is free of ingredients with high global warming potential by greenhouse effect (GWP) affected by the regulation (EU) No 517/201.
  • CE marked to EN 14318-1:2013.
  • Shelf life of components: component A: three months, component B: six months.
  • KIWA (BDA) Certified.

The system can be processed using high- or low-pressure machines or manually. This process consists on the injection of a mixture of the two components by means of a suitable machine into the cavity to insulate.


Machine conditions:

  • Mixing ratio of components: 1:1 (volume).
  • Component temperatures: +18 to +22ºC (High-pressure injection machines and low-pressure machines), +40 to +45ºC (High-pressure machines also used for spray).
  • Component pressure:100–150 bar (High-pressure injection machines), 60–110 bar (High-pressure machines also used for spray), 1–10 bar (Low-pressure machines).

Environmental conditions:

  • Ambient temperature: between +10 and +40ºC.
  • Relative humidity: < 85%.

Substrate conditions:

  • Substrate temperature: +10 and +40ºC.

Substrate humidity:

  • Porous substrates: ≤ 20% (Concrete: ≤ 5%).
  • Nonporous substrates: Without condensations on substrate.

Manual processing:

  • The two components should be blended thoroughly with an adequate mixer for approximately 15 seconds at a speed above 1500 rpm.
  • The mixer and mixing vessels must be clean and dry.
  • The mixing vessel should have an adequate shape, such that the components can be blended completely (cylindrical).

Under favourable weather conditions, the rigid spray polyurethane foam Elastopor has good adhesion to most constructions materials (concrete, brick, wood, steel). They must be clean (without dust or grease), dry, and in case of metallic substrates, free of rust.

  • If the adhesion is not acceptable under these conditions, a previous treatment like a primer may be necessary.
  • Nevertheless, due to the wide range of substrates and primers used in construction, it is not possible to guarantee perfect adhesion of this system to all surfaces. It is therefore recommended to test adhesion in each case.

Consult manufacturer for details.

General information

Color

Purple

Material

Polyurethane (PUR)

Shape

Formless

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

Ten year

Uniclass

Pr_25_31_28_66 Polyurethane (PUR) injected foam insulationPrimary

CAWS

P11/55 Polyurethane foam cavity wall stabilization system

P11/240 Polyurethane foam cavity fill

Specification data - Polyurethane (PUR) injected foam insulation

Standard

To EN 14318-1:2013.

Thermal conductivity (maximum)

0.027 W/m·ᵒK.

Fire performance

NPD.

Materials

Polyols, additives and MDI.

Guidance for specification option:

Component A: Mixture of polyols and additives (catalysts, surfactants and blowing agents), Component B: MDI (diphenylmethane diisocyanate).

Viscosity at 20°C

Component A: 570 mPa.s, Component B: 300 mPa.s.

Manufacturer guidance

Method: G133-07.

Mixing emulsions

Mixing ratio (weight): 100:110.

Manufacturer guidance

Method: G132-01.

Density

Component A: 1.12 g/ cm³, Component B: 1.23 g/ cm³.

Guidance for specification option:

At 20ºC.

Manufacturer guidance

Method: G133-08.

Closed cell content

To ISO 4590, ≥ 90%.

Thickness

70 mm.

Thermal resistance

2.60 m² ·K/W.

Water vapour resistance factor

To EN 12086, ≥85 μ.

Water absorption

To EN 1609, ≤0.20 kg/m².

Guidance for specification option:

Short term water absorption by partial immersion.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Third party certifications

KIWA BDA

KIWA BDA

Walltite - KIWA

Literature

Walltite Technical Guide - Hard to Treat Areas

Walltite Technical Guide - Hard to Treat Areas

Walltite LWP CV 100 Technical Data Sheet

Walltite LWP CV 100 Technical Data Sheet

BASF Walltite LWP CV 100 Brochure

BASF Walltite LWP CV 100 Brochure

Similar products from ECON Building Products – BASF Distributor

BASF Elastospray® LWP 1672/4  - Closed Cell Spray Insulation

BASF Elastospray® LWP 1672/4 - Closed Cell Spray Insulation

BASF Skytite® LWP 1672/2 - High Density Spray Insulation

BASF Skytite® LWP 1672/2 - High Density Spray Insulation