NBS Source
I'm a manufacturer
Compare variants

Bauder SVP Cover

Verified by manufacturer 2 days ago

RBM 110 = GB14109110

Bauder Ltd Variant:
Third party certifications:
  • CCPI System

    CCPI System

    Certificate type

Flat roof soil vent pipe covers.

Jump to:
+44 (0)1473 257671 Website

Application

For the weatherproofing of soil vent pipes

Description

A range of stainless-steel covers with integral membrane flange. The range includes variants to cover 110 mm and 160 mm diameter soil vent pipes that protrude above the level of the proposed new waterproofing system by a maximum of 600 mm.

Features and benefits:

  • The unit is supplied in three parts to create an effective seal to the inside of the soil vent pipe, whilst providing a neat, watertight detail.
  • Reinforced Bituminous Membranes (RBM) or Polyvinyl chloride (PVC) flanges are available.

Only to be used as part of a full Bauder Bituminous or Single Ply Thermofol or Cold Liquid Systems (LiquiTEC or LiquiTOP System with PVC flanges only).

General information

Color

Grey

Silver

Material

Stainless steel

Shape

Circle

Width

110 mm

250 mm

160 mm

Manufacturer guidance

Width is given to align with the diameter of soil vent pipes these cover

Uniclass

Pr_30_59_29_74 Roof terminalsPrimary

CAWS

J41/485 Roof ventilators

J42/490 Roof ventilators

J41/80 Roof ventilators

Specification data - Roof terminals

Purpose

Soil pipe terminal cover.

Ventilation opening

110 mm external diameter (maximum).

Colour

Silver.

Execution

-

Manufacturer guidance

Bauder SVP Covers (suitable for RBM membranes) of the correct size are to be placed over the existing soil vent pipes after the Bauder underlayer has been installed. The integral membrane must be fully torched onto the underlayer before the capping sheet is installed above, all in accordance with Bauder instructions.

 

Bauder SVP Covers (suitable for PVC membranes) of the correct size are to be placed over the existing soil vent pipes after installation of the main waterproofing membrane. The integral membrane flange is supplied blue grey and must be welded to the main waterproofing membrane, if the membrane on the main area is a different colour it may be necessary to install an additional patch over the integral membrane flange.

 

Bauder SVP Covers (suitable for PVC membranes) of the correct size are to be placed over the existing soil vent pipes after the Bauder LiquiTEC system has been installed. A layer of Bauder LiquiDETAIL is to be used to seal the integral flange to the main area, terminating at the base of the stainless steel pipe, all in accordance with Bauder instructions.

 

Bauder SVP Covers (suitable for PVC membranes) of the correct size are to be placed over the existing soil vent pipes after the LiquiTOP has been installed. A separate layer of LiquiTOP is to be used to seal the integral flange to the main area and taken up the outside of the installed SVP Cover to a minimum of 150 mm and sealed with a jubilee clip, all in accordance with Bauder instructions.

Material

Stainless steel.

Width

125 mm.

Membrane

Reinforced Bituminous Membranes (RBM).

Sustainability data

Material

Stainless steel

Third party certifications

CCPI System

CCPI System

Bauder Bauderflex-BauderflexGreen-CCPI

CCPI System

CCPI System

Bauder BTRS-BTGRS CCPI System Certificate

CCPI System

CCPI System

Bauder Airtech CCPI

CCPI System

CCPI System

Bauder BTRS-BTGRS Plus CCPI

CCPI System

CCPI System

Bauder LiquiDEK Roof System CCPI

CCPI System

CCPI System

Bauder LiquiTEC Balcony Walkway System CCPI

CCPI System

CCPI System

Bauder LiquiTOP Roof System CCPI

CCPI System

CCPI System

Bauder Thermofol CCPI

CCPI System

CCPI System

Bauder Thermoplan CCPI

Literature

Bauder SVP Cover - Technical Data Sheet

Bauder SVP Cover - Technical Data Sheet