Verified by manufacturer 3 months ago
Certificate of Compliance
Certificate type
EPD
Certificate type
DoP
Certificate type
Combined waterproofing and gas resistant concrete.
Designated concrete suitable for use in commercial, tunnels and industrial applications.
Cementaid’s range of waterproofing, gas and radon protection solutions are practical and time-proven to produce truly damp-proof, highly durable concrete which can be used either as stand-alone protection (or part of dual protection systems, when required).
Caltite modified concretes have a successful track record of over 60 years of helping designers, developers and owners waterproof and protect concrete structures, even under the most aggressive and corrosive conditions.
Caltite GR (30 Ltrs) is a water and gas resisting concrete. Cementaid’s Caltite GR system will provide waterproofing, gas and radon protection solution and is a practical solution as will produce truly damp-proof and gas resistance concrete.
Features and benefits:
Color | Grey |
Finish | Other Guidance for specification option: All concrete to be properly finished according to the Architect’s or consulting structural engineer’s specification. |
Material | Concrete |
Shape | Formless |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 20 year |
Uniclass | |
CAWS | E10/20 Designated concrete E10/418 Proprietary admixture E10/132 Designed concrete |
Ready mixed concrete producer | |
Third party accreditation | Currently certified by a body accredited by UKAS for product conformity certification of ready-mixed concrete. |
Source | |
Name and address of depot | Submit before any concrete is delivered. |
Delivery notes | Retain for inspection. |
Information | |
Mix design robustness | Submit evidence to demonstrate robustness of mix design. |
Declarations of non-conformity from concrete producer | Notify immediately. |
Standards | To BS EN 206, BS 8500-1, and BS 8500-2. |
Concrete designation | C28/35.Guidance for specification option: Minimum. |
Properties | |
Consistence class | S2.Guidance for specification option: Recommended unless otherwise agreed. |
Chloride class | Cl 0.40. |
Aggregates | |
Nominal size (maximum) | 20 mm. |
Additional requirements for aggregates | Absorption not greater than 3%. |
Recycled aggregates | Subject to approval by structural engineer. |
Source of recycled aggregates | Subject to approval by structural engineer. |
Fibres | Carbon steel fibres. |
Admixtures | |
Standard | To BS EN 934-2. |
Type of admixture | Superplasticizing liquid admixture.Guidance for specification option: Caltite GR. |
Air content (minimum) | No requirement. |
Additional mix requirements | Guidance for specification option: Consult manufacturer and insert requirements or omit. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Concrete |
Manufacturing plant location | |
Recyclability | 100% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | % Guidance for specification option: Recycled coarse aggregates subject to approval by structural engineer. |
Expected Life | 60 year |