Catnic TX90/100 Thermally Broken Lintel – Extra Heavy Duty
BBA Agrément Certificate
Certificate type
EPD
Certificate type
Thermally broken cavity wall lintels.
Energy efficiency is a top priority for thermally broken lintels. Replacing traditional lintels with Catnic thermally broken lintels means that heat loss through a window head detail can be reduced by up to 96%.
In a typical four bedroom house with 1,200 square feet, the heat loss through a standard lintel can account for about 6%* of the overall heat loss through the fabric of the house. Using a Catnic thermally broken lintel reduces this to 0.25%, making it extremely effective.
Our lintels are designed to support:
Catnic’s Thermally Broken Lintels comprises powder-coated galvanised steel components on either side of an expanded polystyrene (EPS) insulation core. The steel elements are bonded to the insulation using dedicated, heavy duty adhesive. This unique design provides a complete thermal break between the inner and outer leaves without using brackets, resulting in outstanding thermal performance – ψ (psi) value always 0.05 W/mK or less.
Catnic produce a range of thermally broken cavity wall lintels, suitable for the following cavity sizes:
Lintel features and benefits:
Lintel Safe Working Loads (SWL) and weight are dependent on lintel's length.
Color | Black |
Finish | Powder-coated |
Material | Steel |
Shape | Other |
Length | Bespoke |
Width | 283 mm 308 mm 348 mm 303 mm 328 mm |
Height | 229 mm |
Uniclass | |
CAWS | F30/85 Prefabricated steel lintels F30/755 Prefabricated steel lintels |
SKU Code | TX90/100, TX90/125, TX110/100, TX110/125, TX130/100, TX130/125, TX150/100, TX150/125, TX170/100, TX170/125, TX190/100, TX190/125 |
Standard | To BS EN 845-2. |
Lintel type | Single. |
Material finish and coating reference | Powder coated galvanized steel. |
Sizes | Manufacturer guidance
|
Characteristics | |
Deflection under load | Dependent on length specified. Guidance for specification option: Deflection is proportional to the product length. Calculated as follows: (length as specified - 150)/325. Example values - length of 4800 or 1200 mm: (4800-150)/325 = 14.3 mm. (1200-150)/325 = 3.2 mm. |
Mass | 16.7–21.6 kg/m. |
Resistance to fire | Up to 1 hour. |
Thermal conductivity | 0.030–0.050 W/mK. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Steel |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | Manufacturer guidanceRefer to EPD. |
Recyclability | 96% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 17 % |
Expected Life | 60 year |
Certified
Catnic Cavity Wall Lintel - Extra Heavy Duty - Lintel
Catnic Cavity Wall Lintel - Heavy Duty
Catnic Cavity Wall Lintel - Standard Duty
Catnic External Solid Wall Lintel
Catnic Internal Solid Wall Lintels
Catnic Internal Wall Box Lintel
Catnic Single Leaf Angle Lintel
Catnic Single Leaf Channel Lintel – Standard Duty
Catnic Thermally Broken Lintel - Heavy Duty
Catnic Thermally Broken Lintel - Standard Duty