Verified by manufacturer 2 months ago
CMS50A Bonded brick slip cladding
Lightweight, chemically fixed cladding systems providing a brick slip or render finish.
Insulated cladding system.
Lightweight, chemically fixed cladding systems providing a brick slip or render finish.
Features and benefits:
Color | Beige Black Blue Brown Cream |
Finish | Brick Antiqued Glazed Smooth Sandcreased |
Material | Brick Render |
Shape | Rectangle Other |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 25 year |
Uniclass | |
CAWS | M21/20 External wall insulation system . . . . . . F10/5 Facing brickwork M21/210 External wall insulation system F10/110 Clay facing brickwork |
Preparation | Guidance for specification option: Insert requirements. |
Support rails and brackets | |
Fixing method | |
Material | Starting rail.Guidance for specification option: The manufacturer suggests using a starting rail (supplied by others) at DPC level to form a horizontal starting point for CMS50 Wallclad. Insert requirements. Not required. |
Bracket fixings | Guidance for specification option: Insert requirements. |
Insulation | |
Material | TerraWool Rainclad Plus 140, 50 mm-thick.Guidance for specification option: Insert requirements. To be placed between vertical rails. TerraWool Rainclad Plus 140, 60 mm-thick.TerraWool Rainclad Plus 140, 70 mm-thick.TerraWool Rainclad Plus 140, 80 mm-thick.TerraWool Rainclad Plus 140, 90 mm-thick.TerraWool Rainclad Plus 140, 100 mm-thick.TerraWool Rainclad Plus 140, 110 mm-thick.TerraWool Rainclad Plus 140, 120 mm-thick.TerraWool Rainclad Plus 140, 130 mm-thick.TerraWool Rainclad Plus 140, 140 mm-thick.TerraWool Rainclad Plus 140, 150 mm-thick.Other.Guidance for specification option: Thicknesses >150 mm can be achieved by combining two slabs; insert details. Manufacturer guidanceHigh-density non-combustible stone wool insulation slab with water repelling properties. Density: 140 kg/m³; Thermal conductivity: 0.039 W/m·K. |
Additional mechanical fixings | Metal fasteners.Guidance for specification option: Permanent fixings for fastening the metal sheets and insulation to the substrate before applying brick slips. A minimum of six fasteners are recommended for each board. Refer to manufacturer's fixing guide. The manufacturer recommends temporary fixings be used for the insulation slabs on the substrate before you applying the metal sheet; consult manufacturer's fixing guide for details. Not required. |
Render | |
Material | Cladmate galvanized steel metal sheets.Guidance for specification option: 445 x 1235 mm. Designed to keep brick slips aligned securely in place. The sheets must be fixed to the substrate and the stone wool slab. |
Decorative finish | Bonded brick slip cladding, finish.Guidance for specification option: Metric size brick slips up to 25 mm thickness can be supplied by the manufacturer or other brick suppliers. Consult manufacturer for options and insert requirements. Manufacturer guidanceAttached with Sika 545 adhesive high performance adhesive used to fix the brick slips to the Cladmate metal sheet. Must be applied with suitable sausage gun (by others). 600 mL will cover an area of approx. 3 m². |
Breather membrane | Guidance for specification option: The manufacturer recommends the use of a breathable membrane (supplied by others) behind the cladding system. Insert requirements or omit. |
Mortar | Pointing mortar. Guidance for specification option: Apply using pointing gun, between all 10mm joints. |
Material | Brick Render |