NBS Source
I'm a manufacturer
Compare variants

Corium Brick Cladding - Brick Cladding System

Verified by manufacturer over a year ago

Rustic Edges

Taylor Maxwell Variant:
Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

Brick tile cladding system.

Jump to:
0203 794 9377 Website

Application

External façade installations. Suitable for use on a new building or refurbishment.

Description

The BBA certified Corium brick cladding system can be used on a new build or refurbishment. Corium is a tried and tested brick slip cladding system with main components that are “class A1 as defined by the National Building Regulations”.


If installed, used and maintained in accordance with the stipulations set out in the BBA certificate, Corium “can satisfy or contribute to satisfying the relevant requirements in the relation to NHBC Standards, Part 6 Superstructure (excluding roofs), Chapter 6.9 Curtain walling and cladding.


Features and benefits:

  • Over 2,500 brick tile finishes available with a range of colours and textures.
  • Unique colour blends tailored to specific project designs.
  • Variable tile height options of 50 mm, 65 mm, 140 mm and 215 mm.
  • A horizontal or vertical brick cladding wall appearance is achievable alongside soffits and around windows.
  • The cladding panels have a design life in excess of 35 years in accordance with section 10 of the BBA certificate.
  • There is no build limit with installations on projects in the UK up to 28 storeys as per section 6.2 of the BBA certificate - due consideration should still be given to the full certificate prior to design.
  • BBA approved and certified (19/5693).
  • Fire tested and approved in accordance with EN 13501-1 2007 + A1:2009. Test available on request
  • CWCT TN 76 - test methods for systemised building envelopes.
  • BRE - wind suction testing for European assessment document.
  • Corium tiles are produced as a finished product, using on average 75% less material than traditional brick.
  • Magnelis rails that tiles clip into do not contain any harmful elements and holds a full Environmental Product Declaration (EPD) compliant to EN 10346: 2015.
  • Magnelis rails reduce zinc runoff into soil compared to standard galvanized steel and is 100% recyclable.
  • System can be installed four times faster than traditional brickwork, reducing time required on site.

General information

Color

Other

Finish

Creased

Dragfaced

Sanded

Smooth

Other

Material

Brick

Steel

Shape

Other

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H20/150 Sheet cladding (attached to metal support systems)

H20/10 Sheet cladding

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems

Thermal insulation

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

Breather membrane

-

Material

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

Fasteners

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

Secondary support structure

Magnelis steel carrier rails.

Guidance for specification option:

  • 0.7 mm thick Magnelis metallic coated steel (ZM 310 and ZM 430).
  • Coated with a zinc-aluminium-magnesium alloy, manufactured to BS EN 10346 : 2015.
  • The coating for Magnelis ZM 310 and ZM 430 steel is applied on both sides and is composed of zinc, 3.5% aluminium, 3% magnesium, with a coating weight of 310 and 430 g·m‾², and coating thicknesses of 25 and 35 μm respectively.

Stainless steel carrier rails.

Guidance for specification option:

  • 0.55 mm thick stainless steel (grades 304 and 316).

Cavity fire barriers

-

Horizontal

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

Vertical

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

Cladding panels

-

Material

Fired clay extruded brick tiles.

Panel joints

Movement joints.

Guidance for specification option:

  • To allow for horizontal movement, vertical expansion joints should be provided through tile, mortar and steel backing sections at a maximum of 12 m centres in the brick tile cladding.
  • Horizontal expansion joints to allow for vertical movement should be provided at maximum 9 m centres.
  • Joints should coincide with movement joints in the substrate wall and allow for the same degree of movement (see section 4.7 of the BBA Certificate).

Reveals

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

System accessories

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

Surface finish

Rustic Edges.

Surface texture

Creased.

Dragfaced.

Sanded.

Slate.

Smooth.

Colour

Guidance for specification option:

Consult manufacturer for options and insert requirements.

Height

50 mm.

57.7 mm.

65 mm.

92 mm.

140 mm.

Show more

Manufacturer guidance

Brick height.

Length

215 mm.

Other.

Guidance for specification option:

Other lengths are available on request.

Manufacturer guidance

Brick length.

Thickness

32 mm.

Manufacturer guidance

Brick thickness.

Wind resistance

2.40 kN·m‾².

Fire resistance

Class A1.

Mortar

Parex Historic Mortar KL.

Guidance for specification option:

  • Hydrated lime, sand and ground granulated blast furnace slag mortar.
  • Manufactured to BS EN 998-2: 2016.
  • 15 Parex mortar colours available, consult manufacturer and insert requirements.

Sustainability data

Contains Red List materials

No

Country of material origin

Germany

Country of product manufacture

Germany

Recyclability

100% recyclable magnelis rails

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

Corium Brick Tile Cladding System - 19/5693

Case studies

McDonald Road Fire Station

McDonald Road Fire Station

City Centre Campus, The Manchester College

City Centre Campus, The Manchester College

Weavers Quay and Flour Building, Manchester

Weavers Quay and Flour Building, Manchester

Base, Manchester Science Park

Base, Manchester Science Park