Application


  • Approved for use on all types of lightweight partition wall (including timber stud)
  • Acoustic sealing and firestopping of electrical boxes and switches in plasterboard (to be fitted to the inside or the outside of the box)
  • Can be used for commercial and residential applications
  • Sealing around two electrical boxes within a single stud on opposite sides of wall (back-to-back)
  • Substitutes the need for baffle boxes


Description

Easily moldable intumescent firestop putty pad designed to help protect electrical outlet boxes from fire and smoke.


Features and benefits:

  • Pad can be moulded by hand to fit any size of outlet box.
  • Not electrically conductive.
  • Smoke and gas tight.
  • Substitutes the need for baffle boxes.
  • Permitted for use in Robust Details.
  • Accepted by NHBC.
  • Fire resistance rating of up to two hours.

General information

Color

Red

Material

Rubber

Shape

Rectangle

Length

170 mm

230 mm

Width

170 mm

Height

3 mm

Uniclass

Pr_30_31_68_42 Intumescent puttiesPrimary

CAWS

P12/350 Intumescent putty

Specification data - Intumescent putties

Material

One part synthetic elastomeric intumescent putty.

Form

Preformed pads.

Thickness

3 mm.

Fire resistance

Up to two hours.

Density

1600 kg/m².

Acoustic performance

<71 dB.

Application temperature

0–40 ºC.

Third-party certification

CP 617 Acoustic Test Report on BG Gypwall Quiet sf Partition, 14017A, 14018A, 14019A, 14020A.