NBS Source
I'm a manufacturer
Compare variants

CS Allway® HB Series Car Park Joint Seals

Verified by manufacturer 11 months ago

Allway® HB-300 Car Park Joint Seals

Construction Specialties (UK) Ltd Variant:

Durable EPDM seals for floor expansion joints in car parks or warehouses.

Jump to:
+44 (0)1296 652800 Website

Application

Floor to floor and floor to wall sealing.

Description

One-piece extruded EPDM seals, creating a watertight seal when used with high-strength epoxy adhesive. The serrated edges create epoxy reservoirs and improve adhesion to joint walls. The closed cell design allows the system to achieve ±50% movement capability.


Features and benefits:

  • Joint width: up to 100 mm.
  • Horizontal movement: up to ±50 mm.
  • Vertical movement: up to ±10 mm.
  • Lateral movement: up to ±15 mm.
  • Installed using high-strength epoxy adhesive (supplied by CS). NB. The standard adhesive used with HB models is recommended for concrete finishes and paving and is not compatible with bituminous finishes, such as asphalt.
  • Watertight system when installed as part of a waterproof structure.
  • Suitable for interior or exterior applications, both new and retrofit.
  • Load capability: 1000 kg point load.

General information

Color

Black

Material

EPDM

Uniclass

Pr_35_90_53_86 Strip movement jointsPrimary

CAWS

E40/545 Compressible sealing strip system

E40/545 Compressible sealing strip system

Product range

CS Allway Expansion Joint Covers for Car Parks

Specification data - Strip movement joints

Joint width

75 mm, exposed surface: 75 mm.

Edging

-

Material

Ethylene Propylene Diene Monomer (EPDM).

Finish

Natural.

Colour

Black.

Barriers

Not required.

Guidance for specification option:

Consult manufacturer for details and sizes and insert requirements.

Fire barrier.

Guidance for specification option:

Consult manufacturer for details and sizes and insert requirements.

Manufacturer guidance

Consult manufacturer for details and sizes and insert requirements.

Movement

Horizontal: ±38 mm; vertical: ±10 mm; lateral: ±10 mm.

Joint

Minimum joint depth: 78 mm from FFL.

Literature

CS Allway Expansion Joint Covers (2023)

CS Allway Expansion Joint Covers (2023)

Similar products from Construction Specialties (UK) Ltd

CS Allway® AFW Series Metal Wall and Ceiling Joint Covers - Recess Mounted

CS Allway® AFW Series Metal Wall and Ceiling Joint Covers - Recess Mounted

CS Allway® AL-HD and AL-HDC Series Heavy Duty Metal Floor Joint Covers - Recess Mounted

CS Allway® AL-HD and AL-HDC Series Heavy Duty Metal Floor Joint Covers - Recess Mounted

CS Allway® ALR Series Metal Floor Joint Covers - Recess Mounted

CS Allway® ALR Series Metal Floor Joint Covers - Recess Mounted

CS Allway® ALS Series Metal Floor Joint Covers - Recess Mounted

CS Allway® ALS Series Metal Floor Joint Covers - Recess Mounted

CS Allway® APF Series Heavy Duty Metal Floor Joint Covers - Recess Mounted

CS Allway® APF Series Heavy Duty Metal Floor Joint Covers - Recess Mounted

CS Allway® APF-SM Series Metal Floor Joint Covers -  Surface Mounted

CS Allway® APF-SM Series Metal Floor Joint Covers - Surface Mounted

CS Allway® DGTP and GTP Series Floor Joint Covers - Dual Gasket

CS Allway® DGTP and GTP Series Floor Joint Covers - Dual Gasket

CS Allway® DGTP-HD and GTP-HD Series Heavy Duty Floor Joint Covers - Dual Gasket - Heavy-duty Recess-mounted Floor Covers

CS Allway® DGTP-HD and GTP-HD Series Heavy Duty Floor Joint Covers - Dual Gasket - Heavy-duty Recess-mounted Floor Covers

CS Allway® DGTR and GTR Series Floor Joint Covers - Dual Gasket

CS Allway® DGTR and GTR Series Floor Joint Covers - Dual Gasket

CS Allway® DGTRD and GTRD Series Floor Joint Covers - Dual Gasket

CS Allway® DGTRD and GTRD Series Floor Joint Covers - Dual Gasket