Verified by manufacturer over a year ago
Flexible polyurethane car park deck coating system.
Suitable for refurbishment of existing car parks and on new construction projects.
IMPORTANT: All specification information must be checked against the individual site requirements. Flowcrete advises that specifications are confirmed with their technical experts.
A flexible, solvent free polyurethane car park deck coating system which cosmetically enhances and reduces noise. Suitable for exposed car park decks.
Features and benefits:
Color | Blue Green Grey Purple Red |
Finish | Gloss |
Material | Polyurethane |
Warranty description | Ten year |
Uniclass | |
CAWS | M12/10 Resin flooring M12/110 Resin flooring |
Substrate | |
Testing | Manufacturer guidanceInsert requirements or omit. |
Preparation | Concrete or screed substrate should be a minimum of 25 N/mm², free from laitance, dust and other contamination and should be dry to 95% RH as per BS 8203. |
Primer | Deckshield EP.Guidance for specification option: For new builds. Deckshield SF.Guidance for specification option: For refurbishment. |
Resin flooring | Flexible polyurethane coating. |
Surface treatment | Not required.Deckshield UV topcoat. |
Resin skirtings and upstands | Manufacturer guidanceInsert requirements or omit. |
Adhesion | >1.5 N/mm². |
Certification | CE Marked. |
Chemical resistance | Protects against diesel, antifreeze, hydraulic fluids, chlorides and battery acids. |
Chloride ion resistance | No penetration after 28 days. Guidance for specification option: DOT BD47/94: Appendix B, Method B4,2(d). |
Colour options | Dark Grey. Forest Green. Mid Grey. Tile Red. Traffic Blue. |
Crack bridging | To UNE-EN 1062-7:2004, Class A3 at -10°C; no cracks at -20°C. |
Cure time | Light traffic: 16 hours, Full traffic: one day, full chemical cure: seven days. Guidance for specification option: At 20°C. See manufacturer's literature for other temperatures. |
Impact resistance | Class II: ≥10 Nm. |
Retroflectivity | Not required. Required. Guidance for specification option: By request. Consult manufacturer for details. |
Slip resistance | To UNE-EN 13036-4:2003, Class III: > 55 units wet. |
Temperature resistance | Softens over 70°C and hardens on cooling. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 2 | |
- | 3 |
Deckshield ID (Intermediate Deck System) - Polyurethane Car Park Deck Coating
Deckshield Rapide ED System - Fast Cure MMA Deck Coating
Deckshield Rapide ID System - MMA Intermediate Car Park Deck Coating
Deckshield Rapide SH
Flowchem VE GL System
Flowchem VE HD System
Flowchem VE RC System
Flowchem VE SC System
Flowchem VE SL System
Flowcoat EPN