Verified by manufacturer over a year ago
Indoor Air Comfort – Eurofins
Certificate type
Solvent-free fast cure methyl methacrylate (MMA) car park deck coating system for use on intermediate car park decks.
Suitable for refurbishment of existing car parks and on new construction projects.
IMPORTANT: All specification information must be checked against the individual site requirements. Flowcrete advises that specifications are confirmed with their technical experts.
Methyl methacrylate (MMA) car park deck coating system for use on intermediate car park decks.
Developed to enable fast track applications and reduce downtime, and has bond strength.
Features and benefits:
Color | Blue Green Grey Purple Red |
Finish | Satin Matt |
Material | Methyl methacrylate Guidance for specification option: Methyl methacrylate resin and fillers. |
Warranty description | Ten year |
Uniclass | |
CAWS | M12/10 Resin flooring M12/110 Resin flooring |
Substrate | |
Testing | Concrete or screed substrate should be a minimum of 25 N/mm², free from laitance, dust and other contamination and should be dry to 95% RH as per BS8204. |
Primer | Flowfast Damp Primer with natural quartz. |
Resin flooring | Deckshield Rapide ID.Guidance for specification option: For normal wear areas e.g. parking bays and lighter traffic. Comprises Flowfast flexible binder with SNL filler, natural quartz and Deckshield Rapide topcoat. Deckshield Rapide ID-HD.Guidance for specification option: For heavier wear areas e.g. drive aisles, turning points and ramps. Deckshield Rapide ID-Ramp.Guidance for specification option: For very heavy wear areas e.g. sole entry/ exit ramps and turning points. |
Colour options | Dark Grey. Forest Green. Mid Grey. Tile Red. Traffic Blue. |
Retroflectivity | Not required. Required. Guidance for specification option: Consult manufacturer for details. |
Thickness range | 3–4 mm. |
Certification | CE Marked; Tested & certified to OS8 and EN 1504-2. |
Uses | Intermediate decks of multi-storey car parks. |
Bond strength | To UNE-EN 1542:1999: >1.5 MPa. Guidance for specification option: Measurement of bond strength by pull-off. |
Water vapour transmission | To UNE-EN ISO 7783:2012, Class II: 5 ≤ Sd ≤ 50 m. |
Water permeability | To UNE-EN 1062-3:2008: <0.1 kg/m² x h-0.5. Guidance for specification option: w < 0.1="" kg/m²="" x="">. |
Carbon dioxide permeability | To UNE-EN ISO 7783:2012: >50 m. Guidance for specification option: Diffusion-equivalent air layer thickness (Sd). |
Adhesion | To UNE-EN 13687-1&2:2002: >1.5 MPa. Guidance for specification option: With de-icing salt immersion and thunder shower cycling. Manufacturer guidanceAfter thermal compatibility. |
Abrasion resistance | To UNE-EN ISO 5470-1:1999, weight loss <3000 mg. Guidance for specification option: Taber. |
Slip resistance | To UNE-EN 13036-4:2003, Class III (>55 units wet test). |
Impact resistance | To UNE-EN ISO 6272-1:2012, Class III (>20 Nm). |
Chemical resistance | To UNE-EN 13529:2005, group 1, 3 & 10: No defects & reduction in Shore Hardness <50%. Guidance for specification option: Resistance to chloride ions, to DOT BD47/94: Appendix B, Method B4,2(d): No chloride ion penetration after 28 days. |
Shrinkage | To UNE-EN 12617-1:2004 (linear): <0.3%. |
Reaction to fire | To EN 13501-1, Cfl-s1. |
Cure time | Walk on: 1 hour, full traffic and chemical cure: 2–3 hours. Guidance for specification option: Typical properties achieved in laboratory tests at 20°C and at 50% Relative Humidity for a model specification. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 2 | |
- | 3 |