Application

Typical areas of use are:

  • Fire doors in commercial and public buildings, such as single- or two-leaf doors in hospitals.
  • Airports or government offices.
  • Multi-functional doors in industrial buildings.
  • Fire doors in places such as hotels and government agencies.
  • Heavy duty door such as huge steel door.

Description

Electric strike model with a monitoring contact as potential-free changeover contact, actuated by the latch bolt. 


Features and benefits:

  • Radius keep adjustable by 3 mm.
  • Universal voltage screw-in terminal/ plug-in connection.
  • Compatible with DIN 18250 mortise lock.
  • Compatible with ProFix® 2 striking plates.
  • Optimum sliding ramp for a soft interplay with the latch bolt.
  • Symmetrical design.
  • DIN left/ right as well as horizontal applicable.
  • Bipolar diode.

General information

Material

Steel

Shape

Rectangular

Size

74 x 20.1 x 25.5 mm

Uniclass

Pr_75_30_27_26 Electric strikes and faceplatesPrimary

CAWS

P21/28 Door latches

P21/540 Door latches

Specification data - Electric strikes and faceplates

Standards

To BS EN 14846.

Rated operational voltage (Ue)

10–24 V.dc.

Operation in the event of mains failure

Fail locked.

Monitoring

Monitoring contact (RR).

Material and finish

Stainless steel.

Colour

Self coloured.

Operating temperature range

-15°C to 40°C.

Execution

Installing electric locks.

Product Reference

Electric Strike (FF118F.23)

Resistance

9000 N.

Manufacturer guidance

Break in resistance.

Height

74 mm.

Width

20.1 mm.

Depth

25.5 mm.

AdjustmentRange

3 mm.

Manufacturer guidance

FaFix® adjustment range.

Bolt

6 mm.

Manufacturer guidance

Latch bolt engaging depth.

Cycles

25 0000.

Manufacturer guidance

Load cycles for in-plant test.

Position

Horizontal.

Vertical.

Manufacturer guidance

Installation position.

Electrical resistance

43 Ω.

Power consumption

280–560 mA.

Guidance for specification option:

Rated current consumption 12—24 V.dc.

Latch

200 N.

Guidance for specification option:

Preload AC.

Preload DC (stabilised) 50 N.

Manufacturer guidance

Latch preload.