Verified by manufacturer 9 months ago
Insulated standing seam roof system over a structural deck profile.
Suitable for commercial and offices, distribution centres, education, industrial, mechanical, retail and transport applications.
Euroclad Elite 5 Range provides low pitch roofing solution and can be installed to achieve a wide range of U-values. The Euroseam® external roof profile is attached to halters which are, in turn, attached to the Quattro spacer system and tophats which together create the insulation gap between the outer sheet and the structural deck.
Elite 5 AC1 is used for projects focusing on sound absorption and is specified with a web-perforated structural deck.
Features and benefits:
Finish | Coated |
Material | Glass mineral wool Mineral wool Aluminium |
Shape | Other Guidance for specification option: Standing seam. |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 25 year Guidance for specification option: Guaranteed for up to 30 years with the Elite Plus system guarantee. |
Uniclass | |
CAWS | H31/10 Metal H31/120 Metal |
System performance | External sheet coating fire performance: To BS EN 13501-5:2016, BROOF(T4).Guidance for specification option: By Commission Decision 2000/553/EC. |
Liner sheets | |
Material | Structural deck - JID 100-275-825 Perfo Web (R5T8-DO).Structural deck - JID 137-310-930 Perfo Web (R5T8-DO).Structural deck - JID 153-280-840 Perfo Web (R5T8-DO).Structural deck - JID 158-250-750 Perfo Web (R5T8-DO).Structural deck - JID 200-375-750 Perfo Web (R5T14-DO).Manufacturer guidanceAvailable in 0.75 mm, 0.88 mm, 1.00 mm, 1.25 mm and 1.50 mm thicknesses. Insert requirements. |
Primary fasteners | Carbon steel fixings.Guidance for specification option: Elite guarantee. Stainless steel fixings.Guidance for specification option: Elite PLUS guarantee. |
End and side laps | Not required. |
Air and vapour control layer | |
Material | Euroclad Elite HH VCL. |
Sealing | Euroclad Elite VCL Sealing Tape.Euroclad Elite HH VCL Sealing Tape. |
Spacers | Quattro Bar, 80 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 194.70 mm. System weight: 35.88 kg/m². U-value: 0.29 W/m²K. Quattro Bar, 100 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 214.70 mm. System weight: 36.43 kg/m². U-value: 0.25 W/m²K. Quattro Bar, 120 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 234.70 mm. System weight: 36.99 kg/m². U-value: 0.22 W/m²K. Quattro Bar, 140 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 254.70 mm. System weight: 37.54 kg/m². U-value: 0.20 W/m²K. Quattro Bar, 150 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 264.70 mm. System weight: 37.54 kg/m². U-value: 0.19 W/m²K. Quattro Bar, 160 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 274.70 mm. System weight: 38.09 kg/m². U-value: 0.19 W/m²K. Quattro Bar, 170 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 284.70 mm. System weight: 38.09 kg/m². U-value: 0.18 W/m²K. Quattro Bar, 180 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 294.70 mm. System weight: 38.64 kg/m². U-value: 0.17 W/m²K. Quattro Bar, 185 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 299.70 mm. System weight: 38.64 kg/m². U-value: 0.17 W/m²K. Quattro Bar, 200 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 314.70 mm. System weight: 39.19 kg/m². U-value: 0.16 W/m²K. Quattro Bar, 220 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 334.70 mm. System weight: 39.74 kg/m². U-value: 0.15 W/m²K. Quattro Bar, 240 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 354.70 mm. System weight: 40.30 kg/m². U-value: 0.14 W/m²K. Quattro Bar, 260 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 374.70 mm. System weight: 40.85 kg/m². U-value: 0.13 W/m²K. Quattro Bar, 280 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 394.70 mm. System weight: 41.40 kg/m². U-value: 0.12 W/m²K. Quattro Bar, 300 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 414.70 mm. System weight: 41.95 kg/m². U-value: 0.12 W/m²K. Quattro Bar, 320 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 434.70 mm. System weight: 42.50 kg/m². U-value: 0.11 W/m²K. Quattro Bar, 340 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 454.70 mm. System weight: 43.05 kg/m². U-value: 0.11 W/m²K. Quattro Bar, 360 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 474.70 mm. System weight: 43.61 kg/m². U-value: 0.10 W/m²K. Quattro Bar, 380 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 494.70 mm. System weight: 44.16 kg/m². U-value: 0.10 W/m²K. Quattro Bar, 400 mm Quattro Bracket, halters and tophats.Guidance for specification option: System depth: 514.70 mm. System weight: 44.71 kg/m². U-value: 0.09 W/m²K. Manufacturer guidanceNote: Depths and weights calculated with JID 200-375-750 in 1.5 mm gauge, as this is the deepest and heaviest possible structural deck from shown available options. |
Acoustic insulation | Elite AC1 Acoustic Insulation. |
Thermal insulation | Knauf Factoryclad 40.Rockwool Cladding Roll.Manufacturer guidanceDeclared lambda: 0.040 W/mK. |
External sheets | |
Material | EC 75-400 Euroseam 0.9 mm aluminium plain mill stucco embossed.EC 75-400 Euroseam 0.9 mm aluminium PVDF.EC 75-400 Euroseam 0.9 mm aluminium ARS.EC 75-400 Euroseam 0.9 mm aluminium organic patina. |
Primary fasteners | Carbon steel fixings.Guidance for specification option: Elite guarantee. Stainless steel fixings.Guidance for specification option: Elite PLUS guarantee. |
System accessories | FastenersStandard U-value rooflights.Flashings.Membranes.Non-penetrative clamps.Guidance for specification option: For attachment of PV arrays and other roof mounted installations such as walkways. Tapes.Mastic and sealants.Fabrications.PV solutions.Fall arrest and fall restraint.Roof penetrations.Manufacturer guidanceConsult manufacturer for details. |