Verified by manufacturer over a year ago
BBA Agrément Certificate
Certificate type
A masonry BBA certified system consisting of two different types of insulation boards (enhanced EPS and phenolic), basecoated, meshed and finished off using a thin coat silicone texture.
Suitable for use on the outside of external masonry walls of new or existing domestic and non-domestic buildings, with height and boundary restrictions.
The Epsiwall External Wall Insulation System, comprising mechanically fixed grey enhanced expanded polystyrene (Epsitherm 70E and 90E) or phenolic (PF) insulation boards, with supplementary adhesive where required (adhesive is compulsory when using phenolic insulation), a reinforced basecoat and render finishes.
Finish | Textured |
Material | Silicone Expanded polystyrene (EPS) |
Uniclass | |
CAWS | M21/210 External wall insulation system M21/20 External wall insulation system . . . . . . |
System performance | Durability - 30 years; Fire performance to BS EN 13501-1, class B-s1, d0.Guidance for specification option: When installed and maintained in accordance with the manufacturer's recommendations and the BBA Certificate, the system will remain effective for at least 30 years. Durability - 60 years; Fire performance to BS EN 13501-1, class B-s1, d0.Guidance for specification option: The durability can be extended to 60 years by using different fixings and supplementary adhesive, and by following a planned inspection and an effective maintenance schedule as described in sections 12 and 13 of the systems BBA certificate. Manufacturer guidanceThe systems can improve the thermal performance of external walls and can contribute to satisfying the requirements of the National Building Regulations. For further information please visit the system’s BBA Certificate. |
Preparation | Not required.Wetherby Dubbing Render.Guidance for specification option: Where necessary dub out any hollow or defective areas to leave a suitable surface for the application of the insulation boards. Maximum coat thickness 16 mm. WBS Biocidal Wash.Guidance for specification option: Treat areas of moss, algae and mould growth with WBS Biocidal Wash. WBS Stabilising Solution.Guidance for specification option: Dense smooth surfaces may require treating with WBS Stabilising Solution / Bonding Agent to ensure adequate adhesion on wet fix or render only applications. Manufacturer guidanceRemove any loose material and existing render. |
Support rails and brackets | |
Fixing method | |
Material | WBS base rail. |
Bracket fixings | WBS HIT 6/5 hammerscrew bead fixing.Guidance for specification option: Mechanical fixing. |
Insulation | |
Material | Enhanced EPS 70E.Guidance for specification option: Thicknesses compatible with the system’s certification range between 40–240 mm.
- Board size: 1200 x 600 mm. - Density: 15 kg/m³. - Minimum compressive strength: 70 KN/m². - Thermal conductivity: 0.032 Wm²/K.
- Fire performance: - Flame retardant grade. - Class E (BS EN 13501-1:2002).
- Environmental: - CFC/ HCFC free. - Zero ODP. - GWP less than 5. Enhanced EPS 90E.Guidance for specification option: Thicknesses compatible with the system’s certification range between 40–240 mm.
- Board size: 1200 x 600 mm. - Density: 18 kg/m³. - Minimum compressive strength: 100 KN/m². - Thermal conductivity: 0.030 Wm²/K.
- Fire performance: - Flame retardant grade. - Class E (BS EN 13501-1:2002).
- Environmental: - CFC and HCFC free. - Zero ODP. - GWP less than 5. Phenolic.Guidance for specification option: Thicknesses compatible with the system’s certification range between 60–120 mm.
- Board size: 1200 x 600 mm. - Density: 40 kg/m³. - Minimum compressive strength: 150 KN/m². - Thermal conductivity: 0.021–0.023 Wm²/K (dependent on the thickness of the board).
- Fire performance: - Class C-s1, d0.
- Environmental: - CFC and HCFC free. - Zero ODP. - GWP less than 5. |
Adhesive | Required.Not required.Manufacturer guidanceInsulation boards can be mechanically and adhesively fixed or mechanical only. If a plastic pin fixing is used a minimum of 40% of bedding adhesive must be applied to the back of the boards. If a metal pin fixing is used, then bedding adhesive will not be required. If phenolic insulation boards are specified, the boards must be fully bedded and mechanically fixed. |
Additional mechanical fixings | SPIT ISO range.T-FIX-8M range.T-FIX-8S range.Manufacturer guidanceThe Enhanced EPS Boards are mechanically fixed with WBS approved fixings. Fixing of the phenolic insulation boards may require fixing through the mesh, contact manufacturer for further information. The fixings frequency, type and length are subject pull-out tests and wind load calculations. |
Fire barriers and stops | |
Material | Lamella insulation. |
Fixings | TID-MR range.DHM range.Manufacturer guidanceFixing type, length and frequency are all subject to pull-out tests, job-specific detailing and requirements and wind load calculations. Please contact manufacturer for further information. |
Movement joints | |
Form with | WBS stainless steel movement joints.WBS PVC movement joints.WBS stainless steel surface mounted render stop beads.WBS PVC surface mounted render stop beads.Manufacturer guidanceAll structural movement joints must be mirrored through the EWI System. As a minimum, incorporate the movement joints every 7–10 m vertically and at every other floor level horizontally. Structural Engineers will be required to confirm how much movement will occur and where movement joints are located in the substrate. |
Sealant | Compriband sealing tape between the insulation boards.Guidance for specification option: Where movement joints are required. |
Render carrier or reinforcement | |
Material | WBS Alkali-resistant scrim cloth incorporated into bedding adhesive. |
Mesh size | 50 m².Manufacturer guidanceRoll. |
Fixings | TID-MR range.DHM range.Manufacturer guidanceSecondary mechanical fixings are required on all projects two storeys and above at a rate of 1 per m² as per BRE Report BR135:2013. NHBC require in all cases that a minimum of one non-combustible fixing is installed through the reinforcement mesh per insulation board, in addition to other fixings. |
Render | |
Material | Heck silicone primer.Heck silicone render finish. |
Colour | Manufacturer guidanceAny NCS or RAL reference. Insert requirements. |
Protective coating | None.Aspira render protector.Guidance for specification option: Optional. |
System accessories | None.WBS sealing tape.Guidance for specification option: Pre-compressed, expanding waterproof sealing tape. WBS firtree fixings.WBS jointing pieces.WBS end caps.WBS EVO-STIK silicone sealant.WBS APU bead. |
Samples required | None.Submit samples of textured Wetherby silicone finish for approval. Keep approved samples on site for the duration of the contract for inspection and comparison purposes.Manufacturer guidanceThe manufacturer offers a product sample service, providing a small sample of the finished build-up, colour and texture before a final decision is made. Contact the manufacturer for further information. |
System completion | Inspection of completed installation.Documentation for insulated render systems.O&M manuals and data sheets relevant to the system installed. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 2 | |
- | 2 |
Brick Slip Mesh System - Brick Slip System
Epsibrick External Wall Insulation System - PS1
Epsibrick External Wall Insulation System - PS2
Epsicon 3 - External Wall Insulation System - PS2
Epsicon 3 - External Wall Insulation System - PS3 - External Wall Insulation Dash Finish
Epsitec - Render Carrier Board – 7mm Brick Slips
Epsitec - Render Carrier Board – Silicone Render
HECK ETA 18_0229 - Stone Wool, Silicone Render (A2) and Mineral Render (A1)
KIWA Steel Frame Direct Fix Stone Wool - Stone Wool Insulation
Masonry – Silicone Render - Silicone Render System