Verified by manufacturer 2 months ago
BBA Agrément Certificate
Certificate type
Glass fleece reinforced PVC-P membrane with an integral polyester fleece backing specifically designed for use in adhered applications.
Suitable for use in adhered applications where it provides an ideal solution for roofs with complex geometries or where it is not permissible for fixings to penetrate the substrate.
EshaPlan FB is a glass fleece reinforced PVC-P membrane with an integral polyester fleece backing.
Features and benefits:
For all applicable roofing systems contact Radmat Building Products and see BBA certificate No. 15/5219. For a comprehensive NBS J42 specification contract Radmat Building Products.
Color | Grey Guidance for specification option: Top guide: Light Grey (RAL 7001) or Anthracite (RAL 7015) only. Bottom layer: Anthracite (not defined)/Fleece. |
Material | Polyvinyl chloride (PVC) |
Shape | Rectangle |
Length | 15000 mm |
Width | 2120 mm |
Height | 1.5 mm 1.8 mm 2.0 mm |
Warranty description | 25 year |
Uniclass | |
CAWS | J42/12 Inverted roof covering J42/110 Warm deck roof covering J42/120 Inverted roof covering J42/130 Cold deck roof covering J42/400 Waterproof membrane J42/28 Waterproof membrane J42/10 Warm deck roof covering |
Material | Polyvinyl chloride with plasticizer (PVC-P). |
Standard | To EN 13956. |
Third-party certification | British Board of Agrément (BBA) Certificate. |
Performance characteristics | |
Reaction to fire | To EN 13501-1, Class E. |
Watertightness | To EN 1928, Pass. |
Tensile properties | To EN 12311-2 (A), ≥ 600 N/50 mm. |
Width (minimum) | 2.12 m. |
Thickness (minimum) | 1.5 mm.1.8 mm.2.0 mm. |
Colour | Light Grey (RAL 7001).Anthracite (RAL 7015).Manufacturer guidanceTop side. |
Roll length (minimum) | 15 m. 20 m. |
Flexibility at low temperature | To EN 495-5, ≤ -25°C. Manufacturer guidanceFoldability. |
Dimensional stability | To EN 1107-2, ≤ 0.3%. |
Static load resistance | To EN 12730, ≥ 20 kg. |
Impact resistance | To EN 12691, ≥ 500 mm. |
Peel resistance of joints (to BS EN 12316-1) | To EN 12316-2, ≥ 185 N/50 mm. |
Shear resistance of joints (to EN 12317-2) | ≥ 600 N/50 mm. |
Elongation to break | To EN 12311-2 (A), ≥ 30%. |
Water vapour resistance (minimum) | To EN 1931, 20 000 (± 30%). |
UV stabilization | To EN 1297, Pass. Manufacturer guidanceDurability UV heat and water (5000 hrs). |
Antistatic properties | Required. |
Material | Polyvinyl chloride (PVC) |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 5 % |