Verified by manufacturer 4 months ago
IFCC
Certificate type
A cavity fire barrier system for ventilated cavities of up to 50 mm.
The FF102/50 can be mechanically fixed both horizontally and vertically within ventilated cavities behind rainscreen or cladding systems to act as a cavity fire barrier. Suitable for use within the majority of construction types.
Tenmat’s FF102/50, Ventilated Cavity Fire Barriers, are manufactured from a low smoke zero halogen high expansion intumescent material. They are designed to reinstate fire resisting performance to external wall cavities that are required to be ventilated (open-state) in non-fire conditions.
The FF102/50 is manufactured from a rigid intumescent material allowing it to be provided in a strip format, it is also covered with a protective layer of aluminium foil for ease of handling.
In the event of a fire the FF102/50 intumescent material will expand to close the external wall cavity, providing effective fire resistance, for integrity and insulation for up to 120 minutes depending upon the construction of the external walls.
The FF102/50 is designed for use within cavities of up to 50mm and once installed will close the remaining free air gap in front of the 6mm cavity barrier of up to a maximum of 44mm (depending on construction type).
Features & Benefits:
Color | Silver |
Material | Aluminium Foil Intumescent |
Shape | Rectangle |
Length | 1000 mm |
Width | 75 mm |
Height | 6 mm |
Uniclass | |
CAWS | H92/776 Thermal insulation P10/420 Sleeved mineral wool small cavity barriers P12/360 Mineral wool rigid batts P10/70 Sleeved small cavity barriers P12/40 Mineral wool rigid batts |
Standard | Tested and certified in accordance with ASFP Technical Guidance Document TDG19. |
Fire performance | Guidance for specification option: Fire-rated for up to 120 minutes, depending on the application. Consult manufacturer and insert requirements. |
Material | Intumescent Strip encased in aluminium foil. |
Cavity width | Manufacturer guidanceFor ventilated cavities of up to 50 mm. Insert requirements. |
Air gap | 44 mm. |
Attachment | Stainless steel countersunk head screws, maximum head diameter 11.5 mm, at 250 mm (maximum) centres. |
Platform | Compatible | Version |
---|---|---|
- | 1 |