A cavity fire barrier system for ventilated cavities of up to 450 mm.
The VFB 60/60 can be mechanically fixed horizontally within ventilated cavities behind rainscreen or cladding systems to act as a cavity fire barrier, and can be complemented by the NVFB for vertical applications. Suitable for use within the majority of construction types.
Tenmat’s VFB 60/60 Ventilated Fire Barriers are ’open state’ cavity fire barriers for ventilated cavities of up to 450mm. Each VFB 60/60 consists of a specially formulated fire rated stone mineral wool section with an integral high expansion intumescent seal fixed to the leading edge.
The VFB 60/60 then leaves a maximum 25mm air gap to allow for drainage and maintain ventilation in normal use. In a fire situation the intumescent seal rapidly expands to seal off the air gap and prevent vertical fire spread within the external wall.
The products have undergone extensive fire testing following the principles of BS EN1363-1 and in accordance with ASFP TGD19 (Fire Resistance Test for ‘Open-State’ Cavity Barriers).
The VFB 60/60s are mechanically fixed horizontally within ventilated cavities behind the external wall substrate following the fire compartment line. The VFB 60/60s are used horizontally and can be installed in conjunction with Tenmat NVFB Non-Ventilated Fire Barriers which provide vertical fire separation along fire compartment party wall lines.
Features and benefits:
Color | Black |
Material | Mineral wool |
Shape | Rectangle |
Length | 1000 mm Manufacturer guidance(Total cavity less 25 mm air gap) x 75 x 1000 mm. |
Uniclass | |
CAWS | H92/776 Thermal insulation P10/420 Sleeved mineral wool small cavity barriers P12/360 Mineral wool rigid batts P10/70 Sleeved small cavity barriers P12/40 Mineral wool rigid batts |
Standard | Tested and certified in accordance with ASFP Technical Guidance Document TDG19. |
Fire performance | Fire resistance, 60/60 integrity/ insulation to EN1363-1 / ASFP TGD 19 |
Thickness | 75 mm. |
Cavity width | Manufacturer guidanceFor ventilated cavities of up to 300 mm. Insert requirements. |
Air gap | 25 mm. |
Attachment | Screw fixed.Guidance for specification option: Up to 100 mm cavity. 2 No. multipurpose brackets and 4 no. pigtail screws.Guidance for specification option: 101–240 mm cavity. 3 No. multipurpose brackets and 4 no. pigtail screws.Guidance for specification option: 241–300 mm cavity. |