24 V d.c. electric: actuator
Certificate of constancy of performance
Certificate type
Natural twin flap roof ventilator, suitable for natural day to day ventilation and smoke control.
Suitable for natural smoke control and provision of extract ventilation for most kinds of industrial and commercial buildings.
Natural twin flap ventilator, suitable for natural smoke control and day-to-day ventilation.
Features and benefits:
Also tested in accordance with:
An impact test has been carried out on the Firelight Duo in accordance to GSBau18, achieving 300 Joule with the polycarbonate version and 1200 Joule with the insulated aluminium version.
Also available as a single flap ventilator (Firelight FL2 or FL3); both specified separately.
Color | Silver Other |
Finish | Mill |
Material | Aluminium Polycarbonate Glass |
Shape | Rectangle Square |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | L10/47 Roof ventilators L10/490 Roof ventilators |
Product range |
Standard | To BS EN 12101-2. |
Opening type | B. |
Mounting | Roof mounted, onto curb.Roof mounted, onto glazing.Roof mounted, onto roof sheeting. |
Aerodynamic free area | Manufacturer's standard.Guidance for specification option: Consult manufacturer for maximum overall ventilator size. Determined by the selected type, the chosen controls, the ventilator’s application, its geometry and its installation angle. Manufacturer guidanceAerodynamic coefficient: up to 0.68. |
Reliability classification | Re 1000.Guidance for specification option: 10 000 cycles. |
Snow load classification | Up to 7000 N/m². |
Low ambient temperature classification | T (-15). |
Wind load classification | Up to 9000 N/m². |
Resistance to heat classification | B300-E. |
Arrangement | Twin flaps. |
Dimensions | |
Length | Manufacturer guidanceInsert requirements, 1000–3000 mm overall ventilator lengths in 1 mm increments. |
Width | Manufacturer guidanceInsert requirements; 1000–2500 mm overall ventilator widths in 1 mm increments. |
Height | Manufacturer's standard. |
Controls | 24 V d.c. electric: actuator.Pneumatic controls.Manufacturer guidanceBracket controls (for smaller vents and/or those installed into glazing) or control channel controls (for larger vents and/or heavier lids or need to keep actuator lengths short). |
Materials | |
Ventilator | |
Frame | Corrosion-resistant aluminium alloy.Guidance for specification option: Thermally broken. With stainless steel fixings. |
Glazing | Double glazed.Guidance for specification option: Insert requirements; 28, 30 or 32 mm overall thickness (maximum 50 mm) or customer specified (up to 60 kg/m²). Triple glazed.Guidance for specification option: Insert requirements; 28, 30 or 32 mm overall thickness (maximum 50 mm) or customer specified (up to 60 kg/m²). Polycarbonate, clear.Guidance for specification option: 16 or 25 mm overall thickness or customer specified (16–50 mm). Polycarbonate, opaque.Guidance for specification option: 16 or 25 mm overall thickness or customer specified (16–50 mm). Infill panel.Guidance for specification option: As standard a 2 mm-thick aluminium external sheet, 21 mm-thick infill with a mass of 30 kg/m² and heat transfer of 0.03 W/m·K, 2 mm-thick internal sheet. 25 mm overall thickness as standard, 16–50 mm possible. Noise reduction panel. (DUO RN)Guidance for specification option: Multi-layer system to achieve up to 49 dB Rw. Manufacturer guidance
|
Finish | Mill finish.Polyester powder-coated.Guidance for specification option: 70 µm thick as standard. Anodized.Guidance for specification option: 20 µm thick as standard. Other.Guidance for specification option: Special finishes available on request; consult manufacturer and insert requirements. |
Colour | Standard.Guidance for specification option: Mill finish/ anodized only. RAL.Guidance for specification option: Polyester powder-coated only; insert requirements. |
Integral upstands | |
Material | Corrosion-resistant aluminium alloy. |
Finish | To match frame.Mill finish.Polyester powder-coated.Guidance for specification option: 70 µm thick as standard. Anodized.Guidance for specification option: 20 µm thick as standard. Other.Guidance for specification option: Special finishes available on request; consult manufacturer and insert requirements. |
Colour | To match frame.Standard.Guidance for specification option: Mill finish/ anodized only. RAL.Guidance for specification option: Polyester powder-coated only; insert requirements. |
Seals | Manufacturer's standard.Guidance for specification option: Five high-grade, continuous EPDM and TPE seals, two of which seal the panels into the lids and three between the lids and the frame. As a result there is very low air leakage and a low U-value. |
Accessories | None.Wind baffles on two sides.Guidance for specification option: To improve aerodynamic performance. |
Locking | Double locking. |
Resistance to fire | E. Guidance for specification option: To EN 13501-1. |
U-value | Up to 0.5 W/m²K. Guidance for specification option: Values vary between 1.9 and 0.5 W/m²K. |
Air permeability | Class 4. Guidance for specification option: Tested in accordance with EN 12207: Air permeability. Value is dependent on the type of ventilator specified. |
Watertightness | Class 9A. Guidance for specification option: Tested in accordance with EN 12208: Water tightness. Value is dependent on the type of ventilator specified. |
Sound insulation | Up to 49 dB Rw. Guidance for specification option: Dependent on the type of ventilator specified. |