Verified by manufacturer 17 days ago
Thermal insulation connections suitable for balconies and structural components.
Thermal insulation connections suitable for balconies and structural components.
Halfen HIT insulated connections are high performance, thermally broken connectors for concrete to concrete balcony and structural applications. The double symmetrical compression shear bearings CSB allow for simple and fast installation, both on site or in the precast plant. The product range includes the HIT-HP with an insulation thickness or 80mm and the HIT-SP with 120mm insulation thickness.
Features and benefits:
Product Types:
HIT-HP MVX : for cantilever balconies, capable of transmitting bending moments and positive and negative shear forces
HIT-HP MVX-OU/OD = cantilever connections into walls and beams
HIT-HP ZVX = a shear only connection for propped balconies
HIT-HP ZDX = a shear only connection, capable of transmitting positive and negative shear forces
HIT-HP DD = units capable of transmitting both positive and negative bending moments and shear forces
HIT-HP AT = for parapet walls
HIT-HP FT = for corbel connections
HIT-HP ST = for beam connections
HIT-HP WT = for wall connections
All of these units are also available as HIT-SP with 120mm insulation
Color | Black Red Silver |
Material | Steel |
Shape | Other |
Length | 250 mm 500 mm 1000 mm |
Width | 80 mm 120 mm Manufacturer guidanceInsulation thickness. |
Height | Bespoke Guidance for specification option: Dependent on concrete slab thickness. |
Uniclass | |
CAWS | E42/335 Shear load connectors E42/110 Accessories specified elsewhere E42/335 Shear Load Connectors E42/110 Accessories specified elsewhere |
Certification | EOTA: ETA-18/0189 including fire protection, thermal values and noise reduction DoP no. H10-18/0189. |
Material | Steel/ stainless steel.Guidance for specification option: Tension bars:
Shear bars:
Compression shear bearings:
Casing:
Connecting components:
On-site reinforcement:
|
Thickness of structural deck | Manufacturer guidanceInsert requirements. |
Shear load (maximum) | Manufacturer guidance
|
Fire resistance | Standard HIT Elements fulfill the requirements for REI 120 according to EN 13501-02.Manufacturer guidanceConsult manufacturer for further information. |
Insulation | HIT-HP (80 mm thick). HIT-SP (120 mm thick). Manufacturer guidance
|
Element width | 250 mm. 500 mm. 1000 mm. |
Minimum required concrete cover | 30 mm. 35 mm. 50 mm. |
Offset | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Brackets | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Anchor spacing | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Fixing | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Country of product manufacture | Germany |
Material | Steel |
Manufacturing plant location |