High performance ULTIMATE™ wired mat for fire protection of circular ductwork.

Jump to:
+44 (0) 800 0322 555 Website

Application

HVAC - Fire Protection of Ductwork

Description

U Protect Wired Mat 4.0 Alu1 is a lightweight and easy to install ULTIMATE™ mineral wool wired mat. It combines all the advantages of conventional thermal and acoustic insulation with excellent fire performance and is a component of the U Protect System.


The U Protect system has been tested in accordance to EN 1366-1 and EN 1366-8 and assessed against the criteria in BS 476: Part 24. It offers up to 2 hours passive fire protection in HVAC ventilation and smoke extract ducts as well as up to 1 hour passive fire protection for kitchen ducts.


The fire resistance is also dependent on the application, thicknesses of insulation and the method of installation.

Please contact isover.technical@saint-gobain.com for further details.


Product Features:

  • ULTIMATE™ mineral wool roll incorporating a galvanised steel grid and a black aluminium foil facing
  • Supplied in 30-120mm thicknesses


Fire Classification:

Euroclass A1 Reaction to Fire classification according to EN 13501-1.


Product Benefits:

  • Fire Protection - The U Protect system has been tested in accordance to EN 1366-1 and EN 1366-8 and assessed against the criteria in BS 476: Part 24. It offers up to 2 hours passive fire protection in HVAC ventilation and smoke extract ducts as well as up to 1 hour passive fire protection for kitchen ducts.1
  • Easy to Install - The ULTIMATE™ wired mats offer a lightweight solution compared to traditional stone wool options, ensuring ease of handling and installation, as well as reducing the stress on supporting structures. Their flexibility and mechanical strength allows fast and efficient cutting and fitting. The adhesive used in the system is only required at penetration details rather than at every insulation joint.
  • Fire Classification - Achieves a Euroclass A1 Reaction to Fire classification, according to EN 13501-1.
  • Thermal Performance - Offers energy savings through helping to control temperatures and reduce heat loss or gain within ductwork.
  • Acoustic Benefits - The inherent sound deadening properties of the ULTIMATE™ mineral wool insulation will help to reduce noise from ductwork, improving the acoustic comfort of those living or working within the building.        

1 Fire resistance is dependent on the application, thicknesses used and method of installation.            


The system includes a range of accessories (intumescent paint, glue, screws and tape) to ensure the correct installation of the U Protect system. For further details, please visit isover.co.uk/hvac-insulation/duct-insulation-fire-protection or contact isover.technical@saint-gobain.com


Key Considerations:

When using Isover U Protect Wired Mat 4.0 Alu1, you need to satisfy yourself that use of the product meets all relevant national Building Regulations and guidance as well as local, national and other applicable standards relevant for your construction or application, including requirements in relation to fire.


Please refer to the following product documents:

  • Product Datasheet
  • Declaration of Performance
  • Safe Use Instruction Sheet

General information

Color

Black

Yellow

Finish

Other

Material

Mineral wool

Guidance for specification option:

  • Galvanised steel 
  • Aluminium

Uniclass

Pr_80_77_76_54 Mineral wool pipe section insulationPrimary

CAWS

U90/490 Site-applied insulation to ductwork

U90/490 Site-applied insulation to ductwork

Specification data - Mineral wool pipe section insulation

Standard

To EN 14303.

Thermal conductivity

0.031-0.096 W/m.K (10–400°C).

Guidance for specification option:

  • 0.031 W/m.K at 10°C.
  • 0.035 W/m.K at 50°C.
  • 0.040 W/m.K at 100°C.
  • 0.047 W/m.K at 150°C.
  • 0.054 W/m.K at 200°C.
  • 0.072 W/m.K at 300°C.
  • 0.096 W/m.K at 400°C.


Finish

Aluminium foil faced.

Reaction to fire classification

Euroclass A1 Reaction to Fire classification according to EN 13501-1.

Insulation thickness (minimum)

30 mm.

50 mm.

60 mm.

75 mm.

80 mm.

90 mm.

100 mm.

120 mm.

Vapour barrier

-

Material

Aluminium.

Accessories

Manufacturer's standard.

Guidance for specification option:

A full range of accessories is available to help ensure effective fire protection and straightforward installation.

Execution

Installing mineral wool insulation on ducts.

Product Reference

ISOVER U PROTECT Wired Mat 4.0 Alu1

Sustainability data

Material

Mineral wool

Guidance for specification option:

  • Galvanised steel 
  • Aluminium

Third party certifications

DoP

Declaration of Performance (DoP) : Isover U Protect Slab, U Protect Wired Mat

Similar products from Saint-Gobain Insulation UK

Isover CLIMCOVER Roll Alu2

Isover CLIMCOVER Roll Alu2

Isover CLIMCOVER Roll Alu2 Strong

Isover CLIMCOVER Roll Alu2 Strong

Isover CLIMPIPE Section Alu2

Isover CLIMPIPE Section Alu2

Isover U Protect Accessories

Isover U Protect Accessories