Verified by manufacturer 4 months ago
BBA Agrément Certificate
Certificate type
JUTA GP®5 Gas Barrier is a multi-layer composite of virgin polyethylene (PE) with a central layer of EVOH to give high resistance to the passage of ground gas and organic vapours.
Geomembrane suitable for restricting the ingress of radon, methane and carbon dioxide into buildings from landfill and naturally occurring sources.
Suitable for the following applications:
JUTA GP®5 Gas Barrier is a multi-layer composite of virgin polyethylene (PE) with a central layer of ethylene-vinyl alcohol copolymer (EVOH) to give high resistance to the passage of ground gas and organic vapours. It also acts as a high performance damp proof membrane (DPM).
Features and benefits:
Should be installed in accordance with the product installation guidelines, and in accordance with BS 8485: 2015.
Color | Black Silver |
Finish | Smooth |
Material | Polyethylene |
Shape | Other |
Length | 50000 mm |
Width | 2000 mm |
Height | 0.4 mm |
Warranty description | 60 year |
Uniclass | |
CAWS | D21/38 Gas-retardant membranes D21/350 Gas-retardant membrane J40/120 Loose-laid plastics or rubber sheet damp-proofing J40/140 Loose-laid plastics or rubber sheet gas-retardant membranes J40/35 Loose-laid plastics or rubber gas-retardant membranes |
Material | Virgin polyethylene (PE). |
Purpose | Gas retardance. |
Standard | To BS 8485. |
Performance characteristics | |
Tensile strength (minimum) | To EN 12311-2, >300 N/50 mm. |
Tear resistance | To EN 12310-1, >230 N. |
Resistant to underground gases | Vapour permeability to BS EN ISO 15105-1: Methane: 0.12 ml/m²/day/atm; Carbon dioxide: 1.53 ml/m²/day/atm; Benzene: 0.41 ml/m²/day/atm. To K124/02/95: Radon: 1.0x10-12 m²/s. |
Fire performance | To EN 13501-1, Class E. |
Third-party certification | British Board of Agrément (BBA) certificate. |
Physical properties | |
Colour | Black/ Silver. |
Weight (minimum) | 400 g/m². |
Dimensions | |
Thickness (minimum) | 0.4 mm. |
Width (minimum) | Manufacturer guidanceConsult manufacturer and insert requirements. |
Roll length (minimum) | Manufacturer guidanceConsult manufacturer and insert requirements. |
Recycled content | None – virgin material. |
Resistance to water penetration | To EN 1928, Pass. |
Impact resistance | To EN 12691-B, 500 mm. |
Puncture resistance | To ASTM D 4833, >160 N. |
Accessories | Not required. JUTA GP® DPC. JUTA GP® Primer. JUTA GP® Protection Fleece. JUTA GP® Self Adhesive Membrane. |
Contains Red List materials | No |
Country of material origin | Czechia |
Country of product manufacture | Czechia |
Material | Polyethylene |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 2.35 kg CO₂ eq/kg Self declared |
Recyclability | Fully Recyclable |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 0 % |
JUTA GeoNETEX A pp 300 TT
JUTA GP® Titanbond
JUTA GP® Titanflex - Gas/ VOC/ Hydrocarbon DPM
JUTA GP® TitanTank
JUTA GP®1 Gas Resistant DPM - Gas membrane
JUTA GP®2 - High Performance DPM
JUTA GP®4 Radon Resistant DPM
JUTA GP®5+ Gas Barrier - Gas barrier and damp-proof membrane
JUTA GP®H 0.6mm
JUTA GP®H 1mm - High Performance Hydrocarbon Barrier