Metal liner roof system, with a low thermal transmittance (U-Value) of 0.09 W/m²K.
For roof and wall applications.
Metal liner roof system, with a low thermal transmittance (U-Value) of 0.09 W/m²K. Suitable for use where speed of installation is required.
All work undertaken should be fully in accordance with Kalzip standard recommendations and by Kalzip approved welding contractors. Site welding must be carried out fully in accordance with Approved Welding Procedure Specification ASW/TIG/001 Rev ‘B’ 1997 as defined in BS EN ISO 9606-2 for material gauges between 0.8–3 mm thickness. Site welding operatives must be certified to BS EN ISO 9606-2 standard for material gauges between 0.8–3 mm thickness. The weld test procedure shall be in accordance with BS EN ISO 15614-2: 2005.
Kalzip sheets to be installed as per cladding manufacturer's instructions.
Features and benefits:
Color | Manufacturer guidanceVarious colour options available refer to product literature. |
Finish | Galvanized Manufacturer guidanceVarious finish options available refer to product literature. |
Material | Stainless steel Copper |
Shape | Other Guidance for specification option: Flexible form and shape. |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Ten year Guidance for specification option: Various other warranty periods are available. |
Uniclass | |
CAWS | H31/10 Metal H31/120 Metal |
Product range |
Liner sheets | |
Material | Galvanized steel to BS EN 10326. |
Primary fasteners | 5.5 mm diameter stainless steel fasteners (SFS SXC5-S19-5.5x193).6 mm diameter stainless steel torque controlled fasteners (SDK3-S-377-6.0x45). |
End and side laps | Side laps to be stitched at maximum 400 mm centres with 4.8 mm diameter carbon steel self-drilling stitching fasteners (SL2-T-4.8x20). |
Air and vapour control layer | |
Material | Kalzip VCL Clear - Reinforced virgin polyethylene with 530 MNs/g vapour resistivity. |
Sealing | Seal with one row of sealant tape, not less than 50 mm. |
Spacers | Support clips, steel reinforced polyamide Kalzip E-clips type E.180. |
Thermal insulation | Kalzip Insulation Quilt Type 4 - Manufactured with ECOSE™ Technology. |
External sheets | |
Material | Aluminium Standing Seam 65/400. |
Primary fasteners | 5.5 mm diameter stainless steel fasteners (SFS SXC5-S19-5.5x193).6 mm diameter stainless steel torque controlled fasteners (SDK3-S-377-6.0x45). |
System accessories | Not required.Extruded aluminium alloy (EN AW-6061) gable end hooks.Extruded aluminium alloy (EN AW-6063) drip angle 40 x 20 mm.Extruded aluminium alloy (EN AW-6063) flat bar 22 x 6 mm.Extruded aluminium alloy (EN AW-6063) gable end channel.Extruded aluminium alloy (EN AW-6063) tolerance gable clip extrusion.Fabricated aluminium alloy (EN AW-3004) flashings.Guidance for specification option: Material and finish as per cladding sheets or as per project requirements - consult manufacturer for details. Fabricated aluminium alloy (EN AW-3004) ridge closures (KZ 65/400).Fabricated welded soaker units.Guidance for specification option: Material and finish as per cladding sheets or as per project requirements - consult manufacturer for details. Kalzip profile eaves fillers (KZ 65/400).Kalzip profile ridge fillers (KZ 65/400). |
Thermal transmittance (U-Value) | 0.09 W/m²K. |
Pitch | 1.5° (minimum). |
Bearing width | 58 mm (minimum). |
Type | Black closed cell cross-linked polyethylene with a minimum density of 30 kg/m³. |
Thickness | Guidance for specification option: 30 mm minimum. Consult manufacturer and insert requirements. |
Finish | Aluminium, AluPlusPatina. Aluminium, natural stucco embossed. Aluminium, with a PVDF paint coating. Aluminium, with an HPC paint coating. AluPlus Zinc. |
Thermal insulation | Mineral wool insulation, manufactured in accordance with BS EN 13162; rigid polyisocyanurate foam board, manufactured in accordance with BS EN 13165. |
Shape | Manufacturer guidanceTo suit project requirements. |
Dimensions | Manufacturer guidanceTo suit project requirements. |
Third-party certification | British Board of Agrément Certification No. 98/3481 and Institute fur Bautechnic Zulassungbescheid N R 14.1-181. |
Contains Red List materials | No |
Country of material origin | Germany |
Country of product manufacture | United Kingdom |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 9.61 kg CO₂ eq/kg Manufacturer guidanceRefer to EPD certificate. |
Recyclability | Excellent |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 100 % Guidance for specification option: Recycled aluminium top sheet. |
Aluminium Kalzip Standing Seam - Liner/Deck Roof System - Standing Seam Roofing and Cladding
Aluminium Kalzip Standing Seam - Structural Deck Roof System - Standing Seam Roofing and Cladding
Kalzip Low U-Value Structural Deck System - Aluminium standing seam system
Kalzip Standing Seam - Acoustic Deck Roof System
Kalzip Standing Seam - Deck Roof System 0.20 U-Value
Kalzip Standing Seam - Single Skin - Aluminium standing seam profiles.