Verified by manufacturer 3 months ago
BBA Agrément Certificate
Certificate type
BS EN 1090-1
Certificate type
ISO 9001 Quality Management
Certificate type
Cavity >50 mm | Solid Wall | BBA | Part L Compliant | UKCA | CE | Galvanized & Stainless
All Keystone standard lintels satisfy the thermal performance requirements of Approved Document L of the Building Regulations (E & W), Northern Ireland’s Technical Booklet F and Scotland’s Technical Handbook, section 6. The Keystone patented Thermal Break Plate reduces thermal bridging while adding extra rigidity. Keystone lintels are insulated with expanded CFC-free profiled polystyrene insulation conforming to BS EN 13163. Provide a damp proof course / cavity tray over all lintels. Patented high performance brick bonding system incorporating a BBA approved masonry adhesive. Complex architectural features designed and manufactured off site ensuring seamless integration within the buildings façade. Brick consignment from construction site ensuring shape, size, colour and texture consistency.
For more detailed information applicable to a particular wall construction, contact Keystone Lintels Technical Department. Refer to manufacturers literature for details regarding lintel ranges, height, thickness and Uniformly Distributed Load (UDL) figures.
Performance:
Fire:
Corrosion:
Structural:
Certification:
Special lintels:
Keystone lintels can be supplied to suit a wide range of wall types, loading scenarios and bespoke custom made specials:
Contact Keystone Lintels Technical Department for further information.
Stainless steel:
Additional features:
Contact Keystone Lintels Technical Department for further information.
Color | Silver |
Finish | Galvanized Powder-coated |
Material | Steel Guidance for specification option:
Stainless steel Guidance for specification option:
|
Length | Manufacturer guidanceRefer to Keystone Steel Lintel Manual or contact Keystone Lintels Technical Department. |
Uniclass | |
CAWS | F30/85 Prefabricated steel lintels F30/755 Prefabricated steel lintels |
Standard | To BS EN 845-2.Guidance for specification option: UKCA and CE Marked to BS EN 845-2 Specification for ancillary components for masonry Part 2: Lintels. Manufacturer guidanceDeclaration of Performance certificates are available at: www.keystonelintels.com. |
Lintel type | Composite. |
Material finish and coating reference | Pre-galvanized mild steel to BS EN 10346 DX51D with a zinc coating of 600 g/m² (including both sides). Material Coating Ref L14.Austenitic stainless steel, grade 304 2b BS EN 10088-Part 2 Astm 240 (European Grade 1.4307). Material Coating Ref L3.Austenitic stainless steel, grade 316 2b BS EN 10088-Part 2 Astm 316/316L (European Grade 1.4404). Material Coating Ref L1. |
Sizes | As Lintels schedule. |
Characteristics | |
Resistance to fire | Has achieved a minimum period of 60 minutes in accordance with BS EN 1363-1. |
Thermal conductivity | Part L compliant. |
Duty | Standard duty. Heavy duty. Extra heavy duty. Extreme duty. |
Accessories | Not required. Keying options to suit required plastering applications. Feature plate. Centre stone feature. Brick slip return soffit. |
Recyclability | 100% recyclable |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | Manufacturer guidanceRanging between 15–25%. |