Verified by manufacturer 2 days ago
CWCT Certificate
Certificate type
R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041
Certificate type
The Fusion Facades LandMark I Secret Fix Hook-On Rainscreen features a versatile design, allowing quick adjustments to enhance efficiency, streamline construction, and accelerate project timelines.
Rainscreen cladding with large format panels, including slim panel options for a non-bulky appearance. LandMark Aluminium Rainscreen Cladding.
Compliant with Latest Standards: Fully tested and CWCT certified to meet stringent industry regulations and performance requirements.
Window Interface Integration: Seamlessly connects with window systems and openings, ensuring weatherproofing, durability, and aesthetic consistency.
Horizontal Movement Joint for High-Rise Buildings: Allows structural flexibility, accommodating thermal expansion and contraction in tall structures.
Secret Fixing System: Secret Fix Hook-On with concealed fixings provide a sleek, uninterrupted façade for modern architectural designs.
Fire Safety Standards for High-Rise Design: Meets rigorous fire safety regulations, ensuring compliance and enhanced occupant protection.
Drained & Ventilated: Designed for optimal moisture management, preventing water ingress and condensation issues.
Non-Adhesive Fixing Methods: Secure mechanical fixings eliminate reliance on adhesives, ensuring long-term durability.
Bespoke Design: Customisable cladding solutions tailored to meet unique project specifications and aesthetics.
Finish Guarantee: High-quality finishes with extended warranties for durability and visual appeal.
Color | Silver Other Beige Black Blue |
Finish | Powder-coated Anodized Other |
Material | Aluminium Stainless steel |
Shape | Rectangle Other Square |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Manufacturer guidanceConsult the manufacturer depending on the specified finish and project location. |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
System performance | Design of a rainscreen cladding system |
System manufacturer | Fusion Facades Limited. |
Thermal insulation | Guidance for specification option: Consult manufacturer for options and insert u-value requirements to suit. |
Breather membrane | |
Material | Guidance for specification option: Insert material if the insulation manufacturer requires a breather membrane; otherwise omit. |
Fasteners | Guidance for specification option: Insert fastener type if a breather membrane is required; otherwise omit. |
Secondary support structure | Manufacturer's standard helping hand system. Guidance for specification option: Consult manufacturer for details. Other. Guidance for specification option: Insert requirements, proprietary system such as Nvelope, Hilti, Kladfix or Ash & Lacy. |
Cavity fire barriers | |
Horizontal | Guidance for specification option: Horizontal cavity barriers by others. As specified by a fire engineer, insert details. |
Vertical | Guidance for specification option: Vertical cavity barriers by others. As specified by a fire engineer, insert details. |
Cladding panels | |
Material | LandMark I hook-on panels, 3.0 mm-thick aluminium. LandMark I hook-on panels, 2.0 mm-thick stainless steel. LandMark I hook-on panels, 3.0 mm-thick stainless steel. Manufacturer guidancePanels sizes including overall thickness to be defined under Dimensions. |
Panel joints | Labyrinth joints. Guidance for specification option: Closed joints are recessed 20 mm to match the panel face. Other joint widths/ types are possible; please consult the manufacturer for details. |
Reveals | Guidance for specification option: Insert requirements or omit. Where the reveal is less than 175 mm deep, continuous closer panels are used. For more information, please contact the manufacturer. |
System accessories | Not required. Louvres. Guidance for specification option: Consult manufacturer for details and insert requirements as appropriate. Louvred doors. Guidance for specification option: Consult manufacturer for details and insert requirements as appropriate. Secret doors. Guidance for specification option: Consult manufacturer for details and insert requirements as appropriate. Perforated screens. Guidance for specification option: Consult manufacturer for details and insert requirements as appropriate. FIns. Guidance for specification option: Consult manufacturer for details and insert requirements as appropriate. Other. Guidance for specification option: Consult manufacturer for options and insert requirements or omit. |
Panel finish | Anodized. Guidance for specification option: Aluminium panels only. Polyester powder-coated. Guidance for specification option: Not available for weathering steel panels. Other. Guidance for specification option: Consult manufacturer for options and insert requirements. Not required. Guidance for specification option: Weathering steel only. |
External aluminium cladding colour | Guidance for specification option: Consult manufacturer for options depending on required finish and insert requirements. Refer to drawing or schedule for mixed-colour configurations. |
Dimensions | Guidance for specification option: Insert requirements or drawing reference, schedule etc. as required.
Panels can be removable to gain access to inner components for inspection or maintenance. |
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Aluminium Stainless steel |
A1-A3 (production stage) | Embodied carbon as defined in BS EN 15804 |
Normalised unit | |
Declared unit | 0 kg CO₂ eq/unit Self-declared Lower emissions |
Recyclability | Bespoke product minimal reuse potential. 95% + recyclability |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 95 % |