Verified by manufacturer 2 days ago
CWCT Certificate
Certificate type
R EACTION TO FIRE - CLASSIFICATION REPORT EUI-22-000041
Certificate type
Fusion Facades LandMark III Aluminium Interlocking Rainscreen Cladding System is tested to CWCT standards and holds either A1 or A2 Fire Rating.
Rainscreen cladding with narrow format panels, including slim panel options for a non-bulky appearance. LandMark Aluminium Rainscreen Cladding.
Compliant with Latest Standards: Fully tested and CWCT certified to meet stringent industry regulations and performance requirements.
Window Interface Integration: Seamlessly connects with window systems and openings, ensuring weatherproofing, durability, and aesthetic consistency.
Horizontal Movement Joint for High-Rise Buildings: Allows structural flexibility, accommodating thermal expansion and contraction in tall structures.
Secret Fixing System: Interlocking with concealed fixings provide a sleek, uninterrupted façade for modern architectural designs.
Fire Safety Standards for High-Rise Design: Meets rigorous fire safety regulations, ensuring compliance and enhanced occupant protection.
Drained & Ventilated: Designed for optimal moisture management, preventing water ingress and condensation issues.
Non-Adhesive Fixing Methods: Secure mechanical fixings eliminate reliance on adhesives, ensuring long-term durability.
Bespoke Design: Customisable cladding solutions tailored to meet unique project specifications and aesthetics.
Finish Guarantee: High-quality finishes with extended warranties for durability and visual appeal.
Color | Silver Other Beige Black Blue |
Finish | Powder-coated Anodized Other |
Material | Aluminium Stainless steel |
Shape | Rectangle Other Square |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Manufacturer guidanceConsult the manufacturer depending on the specified finish and project location. |
Uniclass | |
CAWS | H92/120 Rainscreen cladding |
System performance | Design of a rainscreen cladding system |
System manufacturer | Fusion Facades Limited. |
Thermal insulation | Guidance for specification option: Consult manufacturer for options and insert u-value requirements to suit. |
Breather membrane | |
Material | Guidance for specification option: Insert material if the insulation manufacturer requires a breather membrane; otherwise omit. |
Fasteners | Guidance for specification option: Insert fastener type if a breather membrane is required; otherwise omit. |
Secondary support structure | Manufacturer's standard helping hand system. Guidance for specification option: Consult manufacturer for details. Other. Guidance for specification option: Insert requirements, proprietary system such as Nvelope, Hilti, Kladfix or Ash & Lacy. |
Cavity fire barriers | |
Horizontal | Guidance for specification option: Horizontal cavity barriers by others. As specified by a fire engineer, insert details. |
Vertical | Guidance for specification option: Vertical cavity barriers by others. As specified by a fire engineer, insert details. |
Cladding panels | |
Material | LandMark III interlocking panels, 1.5 mm-thick aluminium. LandMark III interlocking panels, 2.0 mm-thick aluminium. LandMark III interlocking panels, 1.0 mm-thick stainless steel. LandMark III interlocking panels, 1.5 mm-thick stainless steel. LandMark III interlocking panels, 2.0 mm-thick stainless steel. LandMark III interlocking panels, 2.0 mm-thick weathering steel. Manufacturer guidancePanels sizes including overall thickness to be defined under Dimensions. |
Panel joints | Labyrinth joints, interlocking. Guidance for specification option: Closed joints are recessed 20 mm to match the panel face. Other joint widths/ types are possible; please consult the manufacturer for details. |
Reveals | Guidance for specification option: Insert requirements or omit. Where the reveal is less than 175 mm deep, continuous closer panels are used. For more information, please contact the manufacturer. |
System accessories | Not required. Louvres. Guidance for specification option: Consult manufacturer for details and insert requirements as appropriate. Louvred doors. Guidance for specification option: Consult manufacturer for details and insert requirements as appropriate. Secret doors. Guidance for specification option: Consult manufacturer for details and insert requirements as appropriate. Perforated screens. Guidance for specification option: Consult manufacturer for details and insert requirements as appropriate. FIns. Guidance for specification option: Consult manufacturer for details and insert requirements as appropriate. Other. Guidance for specification option: Consult manufacturer for options and insert requirements or omit. |
Panel finish | Anodized. Guidance for specification option: Aluminium panels only. Polyester powder-coated. Guidance for specification option: Not available for weathering steel panels. Other. Guidance for specification option: Consult manufacturer for options and insert requirements. Not required. Guidance for specification option: Weathering steel only. |
External aluminium cladding colour | Guidance for specification option: Consult manufacturer for options depending on required finish and insert requirements. Refer to drawing or schedule for mixed-colour configurations. |
Dimensions | Guidance for specification option: Insert requirements or drawing reference, schedule etc. as required.
|
Contains Red List materials | No |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Aluminium Stainless steel |
A1-A3 (production stage) | Embodied carbon as defined in BS EN 15804 |
Normalised unit | |
Declared unit | 0 kg CO₂ eq/unit Self-declared Lower emissions |
Recyclability | Bespoke product minimal reuse potential. 95% + recyclability |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 95 % |