NBS Source
I'm a manufacturer

LoCem® Conductive packing mortar with C-Puck I,II or III - Sacrificial anode option - Corrosion Management System: New Build

Verified by manufacturer 5 months ago

C-Probe Systems

LoCem CPM is a mortar that activates a zinc anode. When connected to the metal structure, zinc sacrificial anodes create a galvanic cell, diverting the flow of electrons and sacrificing themselves.

Jump to:
+44 (0) 1744 611 555 Website

Application

Corrosion protection of steel within reinforced concrete in new construction.


Applications include bridges, buildings, car parks and any kind of civil infrastructure.

Description

C-Puck is a Galvanic (puck) anode that is attached to steel to provide a bimetallic corrosion cell where the most base metal (the anode) corrodes or sacrifices itself in order to protect the more noble metal (steel) to which it is attached.


This anode protects the incipient (ring) anode area that can form around the perimeter of a concrete repair.


It requires no external power supply but its performance can be assessed in a similar way to impressed current CP systems.


Benefits:

  • Provides flexibility with the design parameters influencing life, such as steel density, chloride concentration and humidity.
  • No chemical activation needed
  • Low carbon and ESG compliant when combining zinc and geopolymer manufacturing processes


Compliance:


This anode and packing mortar are manufactured by C-Probe and compliance tested at source to meet:

  • DnV RPB401
  • ISO 12696:2016
  • NACE TM0190 Mortar: EN1504-4
  • PAS8820:2016


C-Puck offers a flexible corrosion management solution designed for all reinforced concrete structures.


It can be used within and outside repair patches to ensure these concrete repairs are protected from incipient anode formation for the long term.

General information

Color

Grey

Silver

Finish

Cement

Material

Zinc

Shape

Circle

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Ss_20_70_10_27 Embedded impressed current anode systemsPrimary

CAWS

C42/305 Proprietary repair systems

Specification data - Embedded impressed current anode systems

System performance

Guidance for specification option:

Insert requirements or omit.

System reference

Guidance for specification option:

Insert details.

Standards

Systems are designed in accordance with BS EN ISO 15257:2017 and BS EN ISO 12696:2022 for cathodic protection of atmospherically exposed reinforced concrete structures.

Products

Guidance for specification option:

Consult manufacturer and insert requirements.

Components (structural resilience kit of parts) includes:

  • LoCem® modular anode units (MAU);
  • Plug & Play d.c. circuitry (wiring);
  • Embeddable corrosion rate probes;
  • AchillesICP power, control and monitoring zonal enclosure;
  • Plug & Play open networks;
  • Network Access Unit (for remote access to data and control).


Achilles interactive Management Server (AiMS):

To provide resilience information and service life tracking for the whole life performance of the protected asset.

Literature

LoCem® Modular Anode Unit (MAU) - Corrosion Protection for New Infrastructure

LoCem® Modular Anode Unit (MAU) - Corrosion Protection for New Infrastructure

Achilles interactive Management Server (AiMS) - Online Control and Monitoring of Your Structure

Achilles interactive Management Server (AiMS) - Online Control and Monitoring of Your Structure