NBS Source
I'm a manufacturer

NIBE F470 - Exhaust air heat pump

Verified by manufacturer 4 months ago

NIBE Energy Systems Ltd

All-in-one exhaust and supply air heat pump which provides heating, ventilation, heat recovery and hot water.

Jump to:
0330 311 2201 Website

Application

Intended for residential properties, both new dwellings and renovations/ replacement.

Description

NIBE F470 is an all-in-one exhaust and supply air heat pump which provides heating, ventilation, heat recovery and hot water efficiently, simply and economically. With its attractive, stylish design and compact size, the heat pump is easy to accommodate and install.


With its built-in hot water tank, immersion heater, circulation pump, fans and control system, the heat pump provides a reliable and economical source of heat. The heat pump can be connected to any low-temperature distribution system, e.g. radiators, convectors or underfloor heating. NIBE F470 can be connected to other heat sources, e.g. district heating.


Thanks to smart technology, the product gives the user control over energy consumption and the efficient control system automatically adjusts the indoor climate for maximum comfort.


Features and benefits:

  • Heating, hot water, supply air, ventilation and heat recovery.
  • Cost-effective residential heating for for new dwellings but also for renovation and replacement market.
  • Connected home with smart technology for an easier way of life.
  • Easy to connect and install.
  • Reliable and economical source of heat.
  • Using accessories, F470 can be docked with other heat sources.
  • R290 refrigerant, GWP = 3.
  • High supply temperature.

General information

Color

Silver

Finish

Powder-coated

Material

Stainless steel

Copper

Brass

Shape

Rectangle

Length

615 mm

Width

600 mm

Height

2075 mm

Warranty description

Two year

Guidance for specification option:

he product is guaranteed for 24 months for parts and labour from the date of installation or 33 months from the date of manufacture, whichever is shortest, as standard.

Uniclass

Pr_70_60_37_04 Air-to-water heat pumpsPrimary

CAWS

T90/505 Air-to-water heat pumps

T90/505 Air-to-water heat pumps

Specification data - Air-to-water heat pumps

Standards

-

Safety and environmental

To EN 378-2:2016.

Test requirements

To BS EN 14511.

Heat pump type

Exhaust.

Mode

Heating.

Coefficient of performance (minimum)

2.74.

Guidance for specification option:

  • COP - A20(12)W35, exhaust air flow 56 l/s (200 m³/h): 3.93.
  • COP - 2 A20(12)W45, exhaust air flow 42 l/s (150 m³/h): 3.24.

Manufacturer guidance

COP - A20(12)W55, exhaust air flow 31 L/s (110 m³/h).

Output

-

Heating

3 kW.

Electrical supply type

Single phase.

Accessories

Not required.

Blocking of supply air heating - BSA 10.

Docking kit - DEH.

Docking kit - Solar 41.

Extra shunt group - ECS.

Communications module - SMS 40.

Room unit - RMU 40.

Solar package - NIBE PV.

Accessory board - AXC 20.

Water heater/ Accumulator tank.

Top cabinet - TOC 30.

Manufacturer guidance

Consult manufacturer's literature for details.

Refrigerant

R290.

Guidance for specification option:

Volume: 0.44 kg.

Current

41 A.

Guidance for specification option:

  • There is an 8 kW step-controlled immersion heater integral to the heat pump, set to 5.3 A by factory default setting.
  • The steps of the immersion heater can be limited to 0 kW/ 2.7 kW/ 5.3 kW/ 8 kW.

Manufacturer guidance

Maximum operating current (compressor and immersion heater).

RatedVoltage

Single phase, 1 x 230 V.

Ingress protection (IP) rating

IP 21.

Manufacturer guidance

Enclosure class.

Pressure

0.25 MPa/ 2.5 bar.

Manufacturer guidance

Opening pressure, safety valve.

Maximum temperature

70℃.

Guidance for specification option:

Factory setting: 60℃.

Manufacturer guidance

Maximum temperature, supply line.

Air flow

28 L/s (at least 20°C); 31 L/s (below 20°C).

Manufacturer guidance

Minimum air flow at exhaust air temperature.

SoundPressure

47.5–50.5 dB(A).

Guidance for specification option:

Sound effect level according to EN 12 102: 51.5–54.5 dB(A).

Manufacturer guidance

Sound pressure level in the installation room.

Volume

70 L (heating section); 170 L (hot water heater).

Weight

207 kg (net weight, empty); 447 kg (mass unit, filled with water).

Sustainability data

Country of product manufacture

Sweden

Recyclability

It is possible to recycle materials for all, or parts, of the product. The refrigerant contents of the product should always be recovered prior to processing. Recycling of the product can be done through fragmentation where the insulation material goes to energy recovery and metals for recycling.

BIM objects

Platform Compatible Version
Revit
-

1

Literature

NIBE F470 - Product Leaflet

NIBE F470 - Product Leaflet

NIBE F470 - Installer Handbook

NIBE F470 - Installer Handbook

Similar products from NIBE Energy Systems Ltd

NIBE F2050 - Air to water heat pump

NIBE F2050 - Air to water heat pump

NIBE S2125 - Air to water heat pump

NIBE S2125 - Air to water heat pump

NIBE S735  - Exhaust air heat pump

NIBE S735 - Exhaust air heat pump