Novia FR Class B‐s1,d0 fire rated Breather Membrane

Verified by manufacturer 18 days ago

Novia Ltd

Class B‐s1,d0 fire rated breather membrane for use on external façade & insulated wall applications over 18m in height. Novia FR is dual CE approved and can be also used in pitched roof applications.

Jump to:
01795 515 110 Website

Application

For use behind insulated external façade installations. Approved for use in high rise wall applications as part of an SFS type light steel frame, and insulated external wall build up. Can also be used on pitched roofs.

Description

Novia FR is a Class B‐s1,d0 fire rated breather membrane primarily used as a fire rated membrane for behind external façades attached to such as SFS light steel frame wall lining systems providing a waterproof yet breathable fire rated covering.

Novia FR is dual CE approved meaning it can be used for both pitched roofs as well as external wall applications. Novia FR is water penetration resistant to W1 which is the highest standard of water penetration resistance, excellent breathability, air tight (when taped and sealed correctly), it is also lightweight and easy to handle.

Novia FR is black on the front and white on the reverse side, with an overlap line for ease of installation. There are no text or images on either side. Novia FR meets EN 13859‐1 for pitched roofing and EN 13859‐2 for walls.


Features and benefits:

  • B‐s1,d0 fire rating when fitted to A1/ A2 materials, (Class D‐s2,d0 when applied directly to timber.)
  • Fire rated and suitable for high rise constructions as per current Building Regulations.
  • CE compliant to EN 13859‐1 (roofs) and EN 13859‐2 (walls).
  • Independent fire test certification.
  • Good UV stability.
  • Monolithic breathable/ vapour permeable membrane design.
  • High performance thermoplastic polyurethane (TPU)/ non‐woven laminate construction.
  • Suitable for use on fully boarded roofs.

General information

Color

Black

Manufacturer guidance

Black on front and white on the reverse side.

Finish

Film

Manufacturer guidance

No logo printed.

Material

Polyurethane

Guidance for specification option:

Thermoplastic polyurethane (TPU)/ non‐woven laminate.

Shape

Other

Length

50000 mm

Width

1500 mm

Warranty description

Lifetime

Uniclass

Pr_25_57_10_94 Vapour-permeable sheetsPrimary

CAWS

H20/150 Sheet cladding (attached to metal support systems)

H20/155 Sheet cladding (attached to timber battens)

H21/110 Vertical timber weatherboarding

H21/111 Horizontal timber weatherboarding

H21/115 Vertical timber weatherboarding

H21/116 Horizontal timber weatherboarding

H21/130 Breather membrane

H21/20 Breather membrane

H30/110 Fibre cement

H30/120 Fibre cement

H30/350 Breather membrane

H30/50 Breather membrane

H31/280 Breather membrane

H31/55 Breather membrane

H60/105 Clay roof tiling

H60/110 Clay roof tiling with counterbattens

H60/120 Concrete roof tiling

H60/125 Concrete roof tiling with counterbattens

H60/145 Clay vertical tiling

H60/155 Concrete vertical tiling

H61/105 Roof slating

H61/110 Roof slating with counterbattens

H61/120 Vertical slating

H62/105 Roof slating

H62/110 Roof slating with counterbattens

H62/120 Vertical slating

H62/125 Roof slating

H62/130 Roof slating with counterbattens

H62/140 Vertical slating

H62/145 Roof slating

H62/150 Roof slating with counterbattens

H64/110 Wood shingle/ shake roofing

H64/120 Wood shingle/ shake roofing with counterbattens

H64/130 Vertical wood shingle/ shakes

H65/105 Clay roof tiling

H65/110 Clay roof tiling with counterbattens

H65/115 Concrete roof tiling

H65/120 Concrete roof tiling with counterbattens

H65/125 Reconstituted slate roof tiling

H65/130 Reconstituted slate roof tiling with counterbattens

H65/135 Ceramic slate roof tiling

H65/140 Ceramic slate roof tiling with counterbattens

H67/110 Metal roof tiling

H67/120 Metal roof tiling with counterbattens

H67/130 Metal vertical tiling

H92/120 Rainscreen cladding

H92/785 Breather membrane

K21/111 Wood floating floor

M30/265 Building paper

P10/320 Breather membrane

P10/65 Breather membrane

Product range

Breather Membranes

Specification data - Vapour-permeable sheets

Standard

To BS EN 13859-1.

To BS EN 13859-2.

To EN 13501-1.

Performance characteristics

Class B fire rated to current Building Regulation requirements.

Class (minimum)

W1.

Material

Thermoplastic polyurethane (TPU).

Form

Non-woven laminate.

Weight (minimum)

110 g/m².

Reflective face

0%.

TensileStrength

Machine direction: 270 N/50 mm; cross direction: 175 N/50 mm to EN 12311‐1.

Elongation (to EN 12311‐1)

25% to EN 12311‐1.

Tear resistance

Machine direction: 90 N; cross direction: 100 N to EN 12310‐1.

Resistance to air penetration

0.05 m³/(m².h.50 Pa) to EN 12114.

Sd value

0.075 m to EN ISO 12572 C.

Resistance to water penetration

Class W1 to EN 1928A.

Class W1 (after ageing) to EN 13859‐1 Annex C.

Reaction to fire

B‐s1,d0 to EN 13501‐1 (when fitted to A1/ A2 materials, D‐s2,d0 when on wood).

Low temperature stability

‐40°C to EN 1109.

UV resistance

Excellent.

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

Europe

Recyclability

Not recyclable

Literature

Novia FR Roof and wall Breather Membrane

Novia FR Roof and wall Breather Membrane

Novia FR Class B-s1,d0 fire Breather Membrane

Novia FR Class B-s1,d0 fire Breather Membrane