Verified by manufacturer 4 months ago
Reflective, airtight vapour-control layer (AVCL).
Suitable for use in insulated wall, roof and floor applications requiring high moisture resistance. Also suitable for use in conjunction with Novia breather membranes for insulated frame applications.
A highly reflective airtight vapour-control layer (AVCL) that delivers a low vapour permeability solution and helps to prevent interstitial condensation problems.
Features and benefits:
Must be installed with Novia dual tape sealing system to provide a fully airtight seal. Consult manufacturer for information.
Tape:
Color | Silver |
Finish | Reflective |
Shape | Rectangle |
Length | 50000 mm |
Width | 1500 mm 2700 mm |
Uniclass | |
CAWS | H20/150 Sheet cladding (attached to metal support systems) H30/261 Air and vapour control membrane H30/30 Air and vapour control membrane H31/261 Air and vapour control membrane H31/45 Air and vapour control membrane H92/780 Air and vapour control layer J21/395 Air and vapour control layer J31/330 Air and vapour control layer J41/395 Air and vapour control layer J42/395 Air and vapour control layer K10/155 Wall lining system (metal studs) K11/115 Battened plywood floating floor K11/125 Battened particleboard floating floor K11/135 Battened oriented strand board floating floor K11/145 Battened cement-bonded particleboard floating floor K11/215 Plywood floating floor K11/225 Particleboard floating floor K11/235 Oriented strand board floating floor K11/245 Cement bonded particleboard floating floor K11/795 Wall lining on metal framing K21/110 Wood flooring K21/111 Wood floating floor K21/115 Wood laminate flooring K21/120 Battened wood flooring K21/130 Battened wood floating floor K21/140 Battened wood laminate flooring K21/145 Composite laminate flooring K21/146 Laminate flooring P10/310 Air and vapour control layer P10/60 Air and vapour control layer |
Product range |
Purpose | Airtight vapour control layer (AVCL). |
Performance characteristics | |
Tensile strength (minimum) | MD/ CD to EN 12311-1, 235/120 N/50 mm. |
Tear resistance | MD/ CD to EN 12310-1, 125/150 N. |
Elongation to break | MD/ CD to EN 12311-2, 125/7%. |
Water vapour resistance (minimum) | To EN 1931, 200 m.Manufacturer guidanceWater vapour permeability. |
Fire performance | To EN 13501-1, Class E.Manufacturer guidanceReaction to fire. |
Root inhibitor | To EN 1849-2, 82 g/m².Manufacturer guidanceNominal weight. |
Physical properties | |
Weight (minimum) | 6.5 kg. |
Dimensions | |
Width (minimum) | 1500 mm. |
Roll length (minimum) | 50 m. |
Standard: | CE approved to BS EN 13984. |
Resistance to water penetration | Requirement achieved to EN 1928. |
Reflectivity | 95% to EN 15976. |
Tape | Novia Double Sided Butyl Tape. Novia Metallised BOPP Tape. Novia Foil Tape. |
Contains Red List materials | No |
Novia 1000 Gauge Vapour Control Layer - Vapour control & air tightness layer
Novia 1200 Gauge Vapour Control Layer - Vapour control & air tightness layer
Novia 1600G Radon Barrier - Gas Barrier and DPM
Novia 500 Gauge Vapour Control Layer - Vapour control & air tightness layer
Novia STRP Vapour Control Layer
Novia VariCheck FR Class B-s1,d0 Fire Rated Variable Vapour Check Air and Vapour Control Layer
Novia VC2 Air Leakage and Vapour Control Layer
Novia VC4000 FR Class B-s1, d0 Fire Rated Reflective Vapour Control Layer - Fire rated vapour control layer
Novia® Methane Pro 390 Gas Barrier - Methane gas barrier
Novia® STRP Pro Vapour Barrier