NBS Source
I'm a manufacturer
Compare variants

Open State Cavity Barrier (OSCB) - Ventilated cavity barrier

Verified by manufacturer 13 days ago

OSCB25

ARC Building Solutions Limited Variant:
Third party certifications:
  • IFCC

    IFCC

    Certificate type

Open state cavity barrier for ventilated cavities.

Jump to:
BOS
+44 (0)113 2529428 Website

Application

  • Suitable for installation horizontally.
  • The cavity barrier must run continuously and uninterrupted apart from where it abuts the vertical cavity barrier. It must not be penetrated by other elements including mechanical or electrical services.

Description

Cavity barriers designed for installation within cavities where ventilation is required in service use. Manufactured from non-combustible rockfibre mineral wool with a reactive intumescent layer, the cavity barrier can provide an air gap of up to either 25 or 44 mm. The intumescent layer will rapidly expand when exposed to heat in a fire event, closing off the air gap and preventing vertical fire spread within the external wall cavity.


Features and benefits:

  • Reactive intumescent element.
  • Either 60 minutes or 120 minutes fire integrity.
  • 25 mm or 44 mm air gap for ventilated cavity.
  • Tested for ASFP TGD19 standards.
  • Fixing brackets included as standard.


ARC OSCB open state cavity barriers should be partnered with ARC Fire Stop Slab installed vertically for a complete cavity barrier solution.

General information

Color

Red

Guidance for specification option:

With:

  • Green strip.
  • Blue strip.
  • Yellow strip.

Finish

Film

Material

Mineral wool

Guidance for specification option:

Rock fibre mineral wool.

Shape

Rectangle

Length

1200 mm

Width

Bespoke

Guidance for specification option:

100–450 mm.

Height

82 mm

Uniclass

Pr_25_80_81_51 Mineral wool fire-stoppingPrimary

CAWS

P12/360 Mineral wool rigid batts

P12/40 Mineral wool rigid batts

Specification data - Mineral wool fire-stopping

Fire performance

60 minutes integrity and insulation.

Widths

Guidance for specification option:

Cavity width less 25 mm. Insert requirements.

Colours

Red with green strip.

Gap

25 mm maximum air gap.

Length

1200 mm.

Thickness

82 mm.

Cavity width

-

Manufacturer guidance

100–450 mm. Insert requirements.

Fixing method

ARC pigtail screw and ARC OSCB fixing bracket.

Third-party certification

ISOQAR and UKAS.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Mineral wool

Guidance for specification option:

Rock fibre mineral wool.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

0 %

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
IFC
-

1

Revit
-

1

Third party certifications

IFCC

IFCC

FoA Report OSCB25

IFCC

IFCC

FoA Report OSCB25PLUS

IFCC

IFCC

FoA Report OSCB44

IFCC

IFCC

IFCC1935

Literature

Open State Cavity Barrier (OSCB) Data Sheet

Open State Cavity Barrier (OSCB) Data Sheet

Similar products from ARC Building Solutions Limited

Cavity Stop Sock

Cavity Stop Sock

Fire Stop Slab - Smoke and Cavity barrier for masonry

Fire Stop Slab - Smoke and Cavity barrier for masonry

Fire Stop Strip - Fire-rated void filler for masonry

Fire Stop Strip - Fire-rated void filler for masonry

Flexi-Closer - Thermal closer for window/ door reveals

Flexi-Closer - Thermal closer for window/ door reveals

Insulated DPC - Thermal cavity closer

Insulated DPC - Thermal cavity closer

Party Wall DPC - Cavity Barrier for Masonry Wall Junction

Party Wall DPC - Cavity Barrier for Masonry Wall Junction

Rockfibre Insulated DPC - Fire-Rated Cavity Closer Window and Door

Rockfibre Insulated DPC - Fire-Rated Cavity Closer Window and Door

Soffit Slab - Mineral Wool fire stopping in the soffit

Soffit Slab - Mineral Wool fire stopping in the soffit

Spandrel Barrier - Fire stopping at party wall and spandrel

Spandrel Barrier - Fire stopping at party wall and spandrel

T-Barrier For Masonry

T-Barrier For Masonry