NBS Source
I'm a manufacturer
Compare variants

Parallel 125 Double Glazed Partition System

Verified by manufacturer 15 days ago

50 dB Rw | 2 x 10.8 mm Acoustic Laminate Glass

Radii Variant:
Third party certifications:
  • ISO 9001 Quality Management

    Certificate type

  • ISO 45001 Health and Safety Management

    Certificate type

Parallel 125 is an exceptional acoustic double glazed solution offering Rw 55 dB — ideal for executive boardrooms. Bespoke options available. An ideal match w/Radii's adaptable demountable crosswall.

Jump to:
BOS
+44 (0)20 7952 4830 Website

Application

All sectors: Commercial, Education, Healthcare, MOD, Airport and Rail, Industrial, Hospitality, Residential and Public.

Description

Parallell 125 is capable of achieving a highly impressive Rw 55 dB, with the 125 mm depth of this double glazed partition system seeing it fit easily alongside stud walls of varying thicknesses and offering exemplary noise reduction performance.


Features and benefits:

  • Achieves up to Rw 55 dB as standard.
  • Uses two 16.8 mm acoustic laminated glass.
  • Deflection up to +/- 25 mm.
  • Range of base track heights available measuring from 25 mm up to 40 mm.
  • Up to 3000 mm in height or 3650 mm with transom bars.


Please note that acoustic, fire rated and structural certification and support for Radii products and systems is available on a project-specific basis. Please contact the specification team directly for further information.

General information

Color

Clear

Finish

Powder-coated

Anodized

Polished

Manufacturer guidance

Polyester Powder Coated RAL, Polished & Chemically brightened, Linish & Chemically brightened, Etch & Anodise -

Material

Aluminium

Glass

Manufacturer guidance

Aluminium (6063 T6) / Glass

Shape

Other

Length

Bespoke

Width

125 mm

Height

Bespoke

Warranty description

-

Manufacturer guidance

Dealt with on a project specific basis as part of the O&M process. 

Uniclass

Pr_25_71_57_60 Partition panelsPrimary

CAWS

K30/10 Relocatable partition system

K30/130 Relocatable partition system

Product range

Radii Glass Partitions / Parallel

Specification data - Partition panels

Unit size

-

Thickness

125 mm.

Partition height (nominal)

-

Manufacturer guidance

Insert requirements. For partitions over 3 m high, please consult with manufacturer.

Width (nominal)

-

Manufacturer guidance

Insert requirements. For panels over 1200 mm wide, please consult with manufacturer.

Deflection allowance (maximum)

-

Head

No deflection 25 mm deep x 125 mm wide aluminium channel.

Guidance for specification option:

Surface Mounted Deflection Head

±15 mm deflection 73 mm deep x 125 mm wide two part aluminium channel.

Guidance for specification option:

Surface Mounted Deflection Head

±25 mm deflection 83 mm deep x 125 mm wide two part aluminium channel.

Guidance for specification option:

Surface Mounted Deflection Head

±15 mm deflection 15 mm visible aluminium channel.

Guidance for specification option:

Recessed Deflection Head – Co-ordination required with ceiling contractor. 

±25 mm deflection 25 mm visible aluminium channel.

Guidance for specification option:

Recessed Deflection Head – Co-ordination required with ceiling contractor. 

Floor

Not applicable.

Manufacturer guidance

System does not offer deflection at floor level - consult with manufacturer for system weights.

Verticals

-

Manufacturer guidance

Lateral deflection available to suit design requirements - consult with manufacturer

Panel partition type

Double glazed system.

Framing, fixing points and joints

Floor detail: surface mounted aluminium U channel screw fixed.

Floor detail: 25 mm deep x 125 mm wide as standard.

Guidance for specification option:

 – larger base details available.

Wall abutments: surface mounted aluminium U channel screw fixed into drylined partition.

Wall abutments: 25 mm deep x 125 mm wide as standard.

Guidance for specification option:

– larger abutment details available.

Corners: mitered panel to panel joint with 2 mm joint tape.

Solid panels

-

Type

18 mm MFC.

18 mm Aluminium Faced MDF.

18 mm Veneered MDF.

Manufacturer guidance

Solid Panels (to be installed into Tech Units).

Joint treatment

-

Type

2 mm dry joint tape between panels. 8 mm shadow-gap around panels.

Finish and colour

Clear – see above joint treatment.

Glazed panels

-

Type

Double-glazed, two 10.8 mm acoustic laminate glass.

Guidance for specification option:

Additional manufacturer treatment options;

  • Annealed laminate.
  • Annealed acoustic laminate.
  • Toughened - heat soaked.
  • LCD switchable.
  • Low iron.


Consult manufacturer for details.

Manufacturer guidance

Double glazed (12.8-16.8 mm): Consult with manufacturer to ensure compliance with test/assessment data.

Integral blinds

Integrated roller blinds into glass cavity.

Integrated micro-venetian blinds into glass cavity.

Additional features

Tech panel to incorporate room booking systems and room controls.

Security post to incorporate access control devices.

Door arrangement

-

Door frames

25 mm x 40 mm rebated aluminium door frame.

Door panels

-

Type

ALIGN - 50 mm wide double glazed door with a drop threshold – 37 dB Rw.

ALIGN - 50 mm wide double glazed door door with a drop threshold – 39 dB Rw.

ALIGN - 50 mm wide double glazed door with a drop threshold – 42 dB Rw.

HOGAN - 50 mm wide single glazed door with a drop threshold – 34 dB Rw.

HOGAN - 50 mm wide single glazed door with a drop threshold – 38 dB Rw.

HOGAN - 50 mm wide double glazed door with a drop threshold – 39 dB Rw.

HOGAN - 64 mm wide double glazed door with a drop threshold – 42 dB Rw.

TIMBER - 54 mm wide acoustic door blank with a drop threshold seal – 30 db Rw.

TIMBER - 54 mm wide acoustic door blank with a drop threshold seal – 35 db Rw.

TIMBER - 64 mm wide acoustic door blank with a drop threshold seal – 40 db Rw.

Vision panels

-

Manufacturer guidance

Applicable with timber doors only - Consult with manufacturer.

Ceiling

-

Type

Consult with manufacturer for interface detail.

Panels

As above.

Method of support

Timber fixing point required within the ceiling/bulkhead – to be supplied by others. Consult with ceiling manufacturer for support detail – co-ordination meeting with all parties concerned to be arranged prior to internal glazing installation.

Joint treatment

Secure fixing into timber provided above.

Perimeters, skirtings, sills

58 mm deep outer deflection profile as standard.

Trims

16 mm x 3 mm aluminium feature bands bonded to the faces 1 & 4 on vertical glass joints with ?? horizontal bands.

16 mm x 5 mm aluminium feature bands bonded to the faces 1 & 4 on vertical glass joints with ?? horizontal bands.

25 mm x 3 mm aluminium feature bands bonded to the faces 1 & 4 on vertical glass joints with ?? horizontal bands.

25 mm x 5 mm aluminium feature bands bonded to the faces 1 & 4 on vertical glass joints with ?? horizontal bands.

50 mm x 3 mm aluminium feature bands bonded to the faces 1 & 4 on vertical glass joints with ?? horizontal bands.

50 mm x 5 mm aluminium feature bands bonded to the faces 1 & 4 on vertical glass joints with ?? horizontal bands.

Hardware

-

Manufacturer guidance

See appropriate door specification for applicable ironmongery options.

Seals

Black perimeter compression seals.

Cable management and outlets

Double glazed/ boarded tech panel to incorporate room booking systems, access control and other electronics - refer to manufacturer with project specific requirements.

Other features

Tech panels.

Access control.

Locking.

Manufacturer guidance

Consult manufacturer for details.

Acoustic performance

50 dB Rw.

Guidance for specification option:

As standard.

Manufacturer guidance

To comply to EN ISO 10140-2 and ISO 717-1: Acoustics vary according to framework/glazing.

Acoustic options subject to further design development, consult manufacturer.


Manifestation

Allowance of two rows 50 mm dots or square (minimum) Opal Frost.

Artwork and custom manifestation to client design.

Manufacturer guidance

In accordance with the requirements of Approved Document K.

StrengthGrade

0.36 kN/m.

Guidance for specification option:

Standard.

0.74 kN/m.

1.5 kN/m.

3.0 kN/m.

Manufacturer guidance

Consult with the manufacturer to ensure the system complies with current regulations

BS 5234:1992 Non-loadbearing screens not protecting a change in adjacent floor level of >380 mm

For glass load resistance criteria, see below;

- BS5234 not applied to “all glass partition screens”

- Nominal line load criteria of “short-term impact load” utilized

- 0.36kN/m applied as linear load at 1100 mm above FFL

- Glass deflection limited to L/65 or 25 mm, whichever is less under load

- Maximum deflection and stress in accordance with the glass performance requirements of EN572/EN12150/EN12543/EN14179 (where heat soaked)

- Building regulations Part N (BS6262 & BS EN 12600) + InsStucEng publication “structural use of glass in buildings”

- 0.36kN/m (default load)

- 0.74kN/m

- 1.5kN/m



BS 6180:2011 Barriers in and about buildings for Atria or protected change in adjacent floor level of >380 mm

Horizontal uniformly distributed line load 1100 mm above FFL (Glass deflection limited to L/65 or 25 mm, whichever is less relative to glass fixings)

Structural Glass based on line-load and attendant UDL + point load 

- 0.74kN/m

- 1.5kN/m

- 3.0kN/m


Coating

Polyester powder coated RAL.

Polished and chemically brightened.

Linish and chemically brightened.

Etch and anodized.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Aluminium

Glass

Manufacturer guidance

Aluminium (6063 T6) / Glass

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

-

Manufacturer guidance

EPD Available On Request.

Recyclability

100

Manufacturer guidance

Up to 100% Glass / 100% Aluminium.

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

70 %

Manufacturer guidance

17–28% for glass.

75% for aluminium.


Expected recycled content for Hydro 2.0.

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

2

IFC
-

1

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001 Certificate

ISO 45001 Health and Safety Management

ISO 45001 Health and Safety Management

ISO 45001 Certificate

Literature

ISO9001 Certificate of Registration

ISO9001 Certificate of Registration

ISO45001 Certificate of Registration

ISO45001 Certificate of Registration

ISO14001 Certificate of Registration

ISO14001 Certificate of Registration

Radii Client Support & Aftercare Flyer

Radii Client Support & Aftercare Flyer

Case studies

108 Cannon Street

108 Cannon Street