Powerlon® UltraBlock thermo-reflective vapour control layers (AVCL) with encapsulated aluminium foil to maximize energy efficiency. Suitable for roof and wall applications.

Jump to:
+44 (0)1347 825200 Website

Application

Powerlon® UltraBlock AVCLs suitable for all roof and wall applications.

Storage and handling:

  • Store the membrane rolls horizontally in a cool, dry, sheltered store.
  • Handle the membrane with care and ensure that the membrane is not creased or folded.

Installation:

  • Powerlon® UltraBlock membranes should be continuous over the whole plan area of the structure.
  • All laps should be sealed with Powerbond® FR Aluminium Tape and the number of joints should be kept to a minimum.
  • Cold roofs with Powerlon® UltraBlock membrane draped between purlins, with the insulation above are harder to seal at the laps. In high-risk areas, a rigid lining sheet is recommended throughout to support the Powerlon® UltraBlock.
  • Warm roofs where the membrane is supported by the structural deck directly beneath is easier to seal. Sealing tape allows for any slight expansion or contraction movement in the decking.
  • Service penetrations should be kept to a minimum. Airtight seals are required around each point of entry including soil pipes, vent pipes, roof lights as well as the roof perimeter.
  • Powerlon® UltraBlock should be laid loose, flat and without wrinkles, ensure that the membrane is not creased or folded.
  • Cold makes Powerlon® UltraBlock less supple. Installations should be avoided when temperatures fall below 5℃. Installation in windy conditions is not recommended as Powerlon® UltraBlock will become difficult to handle and liable to flap in the wind.
  • Timber frame fixings should not puncture the barrier.
  • Joins should only be made where the membrane is supported.
  • A continuous double row of Powerbond® Butyl Tape spaced 75 mm apart is recommended for overlap sealing. The overlap should be sealed using Powerbond® FR Aluminium Tape. For optimal water resistance and airtightness, using both methods is recommended.
  • All joins should be firmly pressed together using a hand-held pressure roller. Only apply tapes in temperatures over 5℃.
  • Prior to covering, Powerlon® UltraBlock should be thoroughly inspected to verify the integrity of the joining and sealing to ensure that no damage has occurred. Any damage should be repaired to ensure an airtight seal.
  • Damaged areas should be repaired using Powerlon® UltraBlock. The patch must not extend beyond 150 mm of the damaged area. Fix the patch using a continuous double row of Powerbond® Butyl Tape, spaced 75 mm apart.
  • Protect Powerlon® UltraBlock from UV exposure. Cover and finish the construction of the VCL installation within a maximum of 3 months.

Overlaps:

  • Horizontal overlaps should be 150 mm minimum.
  • Vertical overlaps should be 150 mm minimum.

See installation instructions for full details.

Description

Powerlon® UltraBlock is a range of thermo-reflective air and vapour control layers (AVCLs) incorporating encapsulated aluminium foil to maximize energy efficiency. The reflective foil surface improves the insulation characteristics of the installation, reflecting heat back into the building.

Air & vapour control layers (AVCLs) ensure that the building envelope is properly sealed to control ventilation and prevent heat loss in compliance with Building Regulations Part L. Installed on the warm side of insulation AVCLs prevent moisture within the building's warm air from reaching the insulation therefore protecting insulates from interstitial condensation.

Powerlon® UltraBlock membranes contribute to both BS 9250 for the airtightness in ‘a well-sealed ceiling’ and BS 5250 aiding the control of condensation within a roof space.

Features and benefits:

  • Suitable for roof and wall installations.
  • Reinforcement scrim.
  • Air barrier for controlling ventilation.
  • Reflective foil layer for enhanced retention of thermal energy.
  • Exceptional water vapour resistance.
  • Powerlon® UltraBlock 300 - suited to high-humidity builds >25,000 MNs/g.
  • Powerlon® UltraBlock 200 - for general builds > 630 MNs/g.
  • UltraBlock SA - Self-adhesive version available.
  • CE approval.

General information

Color

Silver

Green

Clear

White

Finish

Reflective

Material

Plastic

Aluminium

Shape

Other

Guidance for specification option:

Roll.

Length

50000 mm

80000 mm

Width

1500 mm

1600 mm

2000 mm

Uniclass

Pr_25_57_65_60 Plastics sheetsPrimary

CAWS

H31/45 Air and vapour control membrane

H31/261 Air and vapour control membrane

H30/30 Air and vapour control membrane

H30/261 Air and vapour control membrane

J31/330 Air and vapour control layer

J21/395 Air and vapour control layer

J41/395 Air and vapour control layer

J42/395 Air and vapour control layer

P10/60 Air and vapour control layer

P10/310 Air and vapour control layer

H92/780 Air and vapour control layer

Specification data - Plastics sheets

Material

Plastic.

Purpose

Vapour control layer.

Standard

To EN 13984.

Performance characteristics

-

Tensile strength (minimum)

To EN 12311-2, 850 N/50 mm (MD); 500 N/50 mm (CD).

Tear resistance

To EN 12310-1, 250 N (MD); 400 N (CD).

Manufacturer guidance

Nominal.

Elongation to break

To EN 12311-2, 25% (MD); 15% (CD).

Manufacturer guidance

Nominal.

Water vapour resistance (minimum)

>7500 MNs/g.

Fire performance

To EN 13501-1, class E.

Form

Encapsulated aluminium foil.

Physical properties

-

Colour

Silver/ white.

Weight (minimum)

190 g/m².

Dimensions

-

Width (minimum)

1.5 m.

Roll length (minimum)

80 m.

Roll weight

24.0 kg.

Water vapour transmission

To EN ISO 12572 (C), >1500 m.

Manufacturer guidance

Nominal.

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

Europe

Material

Plastic
Aluminium

Recyclability

Suitable for waste to energy

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

Certificate of Registration (2318-QMS-001) - ISO 9001: 2015

CE Marking

CE Marking

Powerlon UltraBlock 200 - CE Marking

Literature

Powerlon ® UltraBlock 300 Inst R3-3

Powerlon ® UltraBlock 300 Inst R3-3

Powerlon® UltraBlock 300 DoP R5-0

Powerlon® UltraBlock 300 DoP R5-0

Powerlon® AVCL TDS R6-3

Powerlon® AVCL TDS R6-3

Powerlon® Building Membranes SDS R5-2

Powerlon® Building Membranes SDS R5-2

Powerlon® UltraBlock 200 DoP R4-2

Powerlon® UltraBlock 200 DoP R4-2

Powerlon® UltraBlock 200 inst LR

Powerlon® UltraBlock 200 inst LR

Powerlon® UltraBlock SA DoP R4-2

Powerlon® UltraBlock SA DoP R4-2

Powerlon® UltraBlock SA Inst R3-1

Powerlon® UltraBlock SA Inst R3-1

Powerlon® Product Catalogue

Powerlon® Product Catalogue

Powerlon® Roofing Membranes TDS R5-7

Powerlon® Roofing Membranes TDS R5-7

Similar products from Industrial Textiles & Plastics Ltd

FlameOUT® Block Premium -  FR Class B B-s1,d0 Flame-retardant Vapour Barrier (AVCL)  - Air and Vapour Control Layer

FlameOUT® Block Premium - FR Class B B-s1,d0 Flame-retardant Vapour Barrier (AVCL) - Air and Vapour Control Layer

FlameOUT® Block Standard - FR Class B B-s1,d0 Flame-retardant Vapour Barrier (AVCL) - Air and Vapour Control Layer

FlameOUT® Block Standard - FR Class B B-s1,d0 Flame-retardant Vapour Barrier (AVCL) - Air and Vapour Control Layer

Powerbase® Low Perm - Gas Barrier Membrane For Protection Against Radon & Low Levels of Carbon Dioxide CO₂ - Gas Barrier Membranes

Powerbase® Low Perm - Gas Barrier Membrane For Protection Against Radon & Low Levels of Carbon Dioxide CO₂ - Gas Barrier Membranes

Powerbase® Multigas Barriers - Protection Against Carbon Dioxide CO₂, Methane & Radon  - Gas Barrier Membranes

Powerbase® Multigas Barriers - Protection Against Carbon Dioxide CO₂, Methane & Radon - Gas Barrier Membranes

Powerbase® VOC - Volatile Organic Compound & Hydrocarbon Gas Barrier Membrane  - Vapour and Gas Barrier Membrane

Powerbase® VOC - Volatile Organic Compound & Hydrocarbon Gas Barrier Membrane - Vapour and Gas Barrier Membrane

Powerlon® VCL 250 & Powerlon® VCL 170 - Vapour Control Layer (AVCL)  - Vapour Control Layer

Powerlon® VCL 250 & Powerlon® VCL 170 - Vapour Control Layer (AVCL) - Vapour Control Layer