NBS Source
I'm a manufacturer
Compare variants

Powerlon® UltraPerm - Breathable Roofing Underlay - Breather Membrane

Verified by manufacturer today

POWERLON® UltraPerm Max

Industrial Textiles & Plastics Ltd Variant:
Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

BBA certified universal breathable roofing underlay for all pitched roof designs and wall applications. Fully compliant to BS 5534:2014 + A1:2015.

Jump to:
+44 (0)1347 825200 Website

Application

Powerlon® UltraPerm BBA certified roofing underlay for all pitched roof designs and timber frame wall applications.

Storage and handling:

  • The membrane must be handled and stored to avoid damage and moisture. Rolls should be stored flat, away from direct sunlight inside a dry storage area.
  • Use non-corrosive fixings, nails should ideally be of galvanized or austenitic steel, phosphor, bronze or silicon bronze. Staples should be of austenitic stainless steel.

Wall installation:

  • Hang horizontally or vertically, fix to the outside of the frame using non-corrosive fixings. With SIPs panels, the membrane can be stapled to the panels.
  • Upper layers should overlap lower layers in a tile effect for water run-off.
  • Ensure the membrane covers the lowest framework by a minimum of 25 mm as it is essential that the lowest timbers in the wall are protected by the breather membrane. Make sure the positions of studs are marked to enable wall tie fixing.
  • At external corners, return the membrane by at least 100 mm. Nail or staple the membrane to every stud, max 200 mm centres. If exposed before cladding secure with battens to prevent wind uplift.
  • For airtightness use Powerbond Acrylic Tape or Powerbond Double Sided Butyl Tape to seal.

Wall overlaps:

  • Horizontal overlaps 100 mm minimum.
  • Vertical overlaps 100 mm minimum.

Roof installation:

  • Powerlon® UltraPerm should be installed with the printed side facing outwards.
  • A staple hammer may be used to position the membrane prior to final battening.
  • Where the membrane is draped over rafters, in the case of an unsupported roof, horizontal laps should be covered by a batten with the bottom edge of the lap projecting less than 25 mm below the batten to ensure the edge is secured against wind uplift.
  • Counter battens, where required should be at least 12 mm thick.
  • Powerlon® UltraPerm may remain unprotected for up to 2 months, recommended practice is to install tiles or slates as soon as possible to minimize the risk of water ingress.
  • Please see installation instructions for specific roof installation requirements.

Description

Powerlon® UltraPerm is a range of high performance breathable underlays, BBA certified for all pitched roof types; warm and cold, supported and unsupported, ventilated and unventilated. Powerlon® UltraPerm can also be used in timber frame wall applications.

Available in a choice of four grades; Lite 92 gsm, Standard 115 gsm, Premium 135 gsm and Max 155 gsm, Powerlon® UltraPerm is tough, durable and tear resistant with exceptional water vapour permeability (breathability) and hydrophobic (water repellent) characteristics.

The Powerlon® UltraPerm range is fully tested to the latest BS 5534:2014 + A1:2015 zones 1-5.

Use Powerbond Acrylic Tape to seal overlaps.

Features and benefits:

  • BBA certified for roofs and walls.
  • Four grades available; 92 gsm, 115 gsm, 135 gsm & 155 gsm.
  • Breathable with high water vapour permeability.
  • Exceptional W1 water resistance.
  • High tensile strength and nail tear resistance.
  • Pre-printed marking lines.
  • Independently tested for full compliance with BS 5534:2014 + A2:2018.
  • CE approval.
  • Bespoke printing available.

General information

Color

Green

Blue

Grey

Black

Material

Composite

Shape

Other

Guidance for specification option:

Roll.

Length

25000 mm

50000 mm

Width

1000 mm

1500 mm

Uniclass

Pr_25_57_10_94 Vapour-permeable sheetsPrimary

CAWS

H62/235 Vapour-permeable underlay

H61/235 Vapour-permeable underlay

H64/307 Vapour-permeable underlay

H60/235 Vapour-permeable underlay

H65/22 Vapour permeable underlay

H60/22 Vapour-permeable underlay

H61/22 Vapour-permeable underlay

H64/22 Vapour-permeable underlay

H65/235 Vapour-permeable underlay

H67/24 Vapour-permeable underlay

H67/290 Vapour-permeable underlay

H75/650 Laying sheet underlay

H75/110 Stainless steel sheet fully supported roof covering

H92/785 Breather membrane

H74/645 Sheet underlay

H73/110 Copper sheet fully supported roof covering

H75/3 Stainless steel sheet fully supported roof covering

H74/3 Zinc sheet fully supported roof covering

H73/3 Copper sheet fully supported roof covering

H72/3 Aluminium sheet fully supported roof covering

H72/51 Sheet underlay

H75/52 Laying sheet underlay

P10/65 Breather membrane

H74/51 Sheet underlay

H31/55 Breather membrane

H74/110 Zinc sheet fully supported roof covering

H92/120 Rainscreen cladding

H31/280 Breather membrane

P10/320 Breather membrane

H72/646 Sheet underlay

H72/110 Aluminium sheet fully supported roof covering

Specification data - Vapour-permeable sheets

Standard

To BS 5534:2014+A1:2015, zones 1-5.

Third-party certification

British Board of Agrément (BBA) certificate.

Manufacturer guidance

BBA Cert. 13/5037.

Performance criteria

-

Water vapour properties

Water vapour transmission determined in accordance with EN ISO 12572(C), 0.02 m.

Fire performance

Reaction to fire: To EN ISO 11925-2, Class E.

Tensile properties

Tensile strength to BS EN 12311-1; 320 N/ 50 mm (MD); 200 N/ 50 mm (CD).

Class (minimum)

W1.

Material

Composite.

Form

Non-woven.

Weight (minimum)

155 g/m².

Tear resistance

To EN 12310-1, 140 N (MD); 230 N (CD).

Roll size

1.0 x 50 m.

Guidance for specification option:

Roll weight: 8.3 kg.

1.5 x 50 m.

Guidance for specification option:

Roll weight: 12.2 kg.

Colour

Green.

Sustainability data

Country of material origin

Europe

Country of product manufacture

Europe

Material

Composite

Recyclability

Not intended for recycling. To be included in the building

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

Powerlon UltraPerm Breather Membranes - For Use In Timber-frame Constructions

BBA Agrément Certificate

BBA Agrément Certificate

Powerlon UltraPerm Breather Membranes - For Use In Cold Non-ventilated Roofs

BBA Agrément Certificate

BBA Agrément Certificate

Powerlon UltraPerm Breather Membranes - For Use In Warm Non-ventilated And Cold Ventilated Roofs

Literature

Powerlon Roofing Membranes TDS R5-7

Powerlon Roofing Membranes TDS R5-7

Powerlon UltraPerm Max Installation Instructions R3-1-1

Powerlon UltraPerm Max Installation Instructions R3-1-1

Powerlon Product Catalogue

Powerlon Product Catalogue

Powerlon Building Membranes Safety Data Sheet R5-2

Powerlon Building Membranes Safety Data Sheet R5-2

Powerlon UltraPerm Lite DoP R4-2

Powerlon UltraPerm Lite DoP R4-2

Powerlon UltraPerm Standard DoP R4-2

Powerlon UltraPerm Standard DoP R4-2

Powerlon UltraPerm Premium DoP R4-2

Powerlon UltraPerm Premium DoP R4-2

Powerlon UltraPerm Max DoP R4-2

Powerlon UltraPerm Max DoP R4-2

Powerlon UltraPerm Lite Inst R3-2

Powerlon UltraPerm Lite Inst R3-2

Powerlon UltraPerm Standard Inst R3-2

Powerlon UltraPerm Standard Inst R3-2

Powerlon UltraPerm Premium Inst R3-3

Powerlon UltraPerm Premium Inst R3-3

Similar products from Industrial Textiles & Plastics Ltd

FlameOUT® Breathe - Class B-s1,d0 Flame Retardant Breather Membrane  - Breather Membranes

FlameOUT® Breathe - Class B-s1,d0 Flame Retardant Breather Membrane - Breather Membranes

Powerlon® Metalix - W1 Metal Roof Breather Membrane  - Metal Roof Separation Layer

Powerlon® Metalix - W1 Metal Roof Breather Membrane - Metal Roof Separation Layer

Powerlon® SupaPerm SP100 - Wall Breather Membrane   - Breather Membrane

Powerlon® SupaPerm SP100 - Wall Breather Membrane - Breather Membrane

Powerlon® UV 120 - UV Resistant Breather Membrane For Partially Open Cladding & Façades - UV Resistant Breathable Facade Membrane

Powerlon® UV 120 - UV Resistant Breather Membrane For Partially Open Cladding & Façades - UV Resistant Breathable Facade Membrane

Powerlon® UV 145 FR - UV Resistant Breather Membrane For Partially Open Cladding & Façades - UV Resistant Breathable Facade Membrane

Powerlon® UV 145 FR - UV Resistant Breather Membrane For Partially Open Cladding & Façades - UV Resistant Breathable Facade Membrane

Powerlon® UV 160 SA - UV Resistant Breather Membrane For Partially Open Cladding & Façades - UV Resistant Breathable Facade Membrane

Powerlon® UV 160 SA - UV Resistant Breather Membrane For Partially Open Cladding & Façades - UV Resistant Breathable Facade Membrane

Powerlon® UV Colour - W1 UV Stable Flame-retardant B Breather For Open Facades  - UV Resistant Breathable Facade Membrane

Powerlon® UV Colour - W1 UV Stable Flame-retardant B Breather For Open Facades - UV Resistant Breathable Facade Membrane

Powerlon® UV Roof  -  W1 UV Resistant Roofing Underlay For Partially Open Clad Roofs & Low Pitched Roofs  - UV Roof Breathable Membrane

Powerlon® UV Roof - W1 UV Resistant Roofing Underlay For Partially Open Clad Roofs & Low Pitched Roofs - UV Roof Breathable Membrane

Safe One® A2 - A2 Limited-combustible Breather Membrane  - Breather Membranes

Safe One® A2 - A2 Limited-combustible Breather Membrane - Breather Membranes

Stamisol A1® - A1 Non-combustible Breather Membrane  - Breather Membranes

Stamisol A1® - A1 Non-combustible Breather Membrane - Breather Membranes