Verified by manufacturer 3 months ago
30 mm
A rigid polyisocyanurate (PIR) foam insulation for use in bituminous roofing systems on suitable surfaces.
For use with adhered or mechanically fastened warm roof
waterproofing such as EshaPlan, EshaUniversal, EshaFlex and EshaGum.
ProTherm PIR ADHERED is a rigid polyisocyanurate (PIR) foam core faced with mineral-filled glass fibre tissue on one side and polypropylene fleece on the other.
Features and benefits:
Spanning metal decks:
ProTherm PIR ADHERED laid over metal decks must not exceed:
spanning distance | insulant thickness:
100 mm | 40 mm;
140 mm | 50 mm and over.
On metal decks the long edges should be at right angles to the corrugations. All board joints should be fully supported by the deck. Please refer to BS 4841-4:2006 for details of thickness of board over metal trough openings.
Color | Black |
Finish | Textured |
Material | Polyisocyanurate (PIR) |
Shape | Rectangle |
Length | 1200 mm |
Width | 600 mm |
Height | Bespoke |
Uniclass | |
CAWS | J41/430 Warm deck roof insulation J42/420 Rigid urethane foam insulation J41/26 Thermal insulation J42/27 Thermal insulation J41/420 Rigid urethane foam insulation |
Standard | Compliant with BS 4841-4: 2006. |
Third party product certification | BBA Certificate 16/5341. |
Fire performance | Achieves BS 476-7: 1997 Class 1 rating for surface spread of flame. |
Thermal conductivity (maximum) | 0.026 W/mK. |
Cross section | Uniform thickness. |
Thickness (nominal) | 30 mm.Guidance for specification option: Made to order. May be subject to extended lead time and minimum order quantities. Please confirm with manufacturer before quoting. |
Face size (length x width) | 1200 x 600 mm. |
Density | 31 kg/m³. |
Facing | Mineral filled glass tissue. |
Edges | Butt. |
Ozone depletion potential | Zero. |
Global warming potential | 3. |
Green guide rating | A. |
Typical compressive strength | <150 KPa. Manufacturer guidanceBS EN 826: 1996 |
Water vapour resistance | 40 MNs/g/m. |
Weight | 4.1 kg. Manufacturer guidanceTypical weight of a 120 mm thick board: |
R-Value | 1.15 m²k/W. |
U-value | 0.72/0.68/0.57 W/m²k. Manufacturer guidanceTypical U value on metal deck/ concrete deck/ timber deck: |
Contains Red List materials | Yes |
Country of material origin | Europe |
Country of product manufacture | Europe |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | Manufacturer guidancek.g.CO2e= |
Recyclability | 0 |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 0 % |