Verified by manufacturer 3 months ago
Double glazed
QA Certificate
Certificate type
BM Trada
Certificate type
Secured By Design
Certificate type
EPD
Certificate type
Qualicoat approval
Certificate type
High-quality laminated flush sash timber aluminium-clad windows with a Scandinavian contemporary design.
Made from timber, with external aluminium cladding, it offers all the benefits of natural wood on the inside and easy maintenance on the outside.
Features and benefits:
Color | Manufacturer guidanceAvailable in a wide range of colours. |
Finish | Matt Anodized Gloss |
Material | Wood Guidance for specification option: Timber frame internally
Aluminium Guidance for specification option: Aluminium cladding externally
Glass Guidance for specification option: Two choices of Insulating glass units: 32 mm or 52 mm. Toughened/ laminated glass where required, allowing for 6.8 mm laminate where secured by design is required. Insulating glass units conform to:
|
Shape | Rectangle Square Other |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Ten year |
Uniclass | |
CAWS | L10/33 Proprietary windows L10/400 Composite windows |
Product range |
Standard | To EN 14351-1:2006 + A2:2016. |
Third-party certification | PAS24:2016; Secured by Design; Q-Mark product certification, FSC, Danish window verification and indoor climate label. |
Dimensions and configurations | As drawing.As schedule.Manufacturer guidanceAll units are bespoke; please contact manufacturer and insert requirements. Note that minimum/ maximum sizes vary depending on operation specified. |
Product performance | |
Fire performance | |
Fire egress | Required.Guidance for specification option: Indicate where these are to be located by schedule or drawing. Not required. |
Weather performance | |
UK exposure category | Generally 1600 Pa to BS 6375-1:2004.Guidance for specification option: Refer to manufacturer's literature (DoP) for details. |
Air permeability | Generally 600 Pa to BS EN 1026/ BS EN 12207 Class 4.Guidance for specification option: Refer to manufacturer's literature (DoP) for details. |
Watertightness | Generally 600 Pa to BS EN 1027/ BS EN 12208 class 9A.Guidance for specification option: Refer to manufacturer's literature (DoP) for details. |
Resistance to wind load | Generally 1600 Pa to BS EN 12211/ BS EN 12210 class 4C.Guidance for specification option: Refer to manufacturer's literature (DoP) for details. |
Durability | |
Operation and strength characteristics | Operating forces to BS EN 12046-1/ BS 13115: Class 1; EN 1191/ EN 12400 repeated open/close 10000/20000: class 2 or 3.Guidance for specification option: Repeated open/close 10000/20000 - class 2 or 3 (depends on opening function). |
Loadbearing capacity of safety devices | To EN 14351-1:2006 +A2:2016. |
Safety | |
User design standards | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details. |
Security level | Not required.To PAS 24 and Secured by Design.Guidance for specification option: On request. |
Environmental | |
Background ventilation | Manufacturer's standard.Guidance for specification option:
|
Acoustic performance rating | 40 dB Rw. |
Thermal | |
Whole window U-value | 1.29 W/m²K. |
British Fenestration Rating Council Window Energy Rating | Consult manufacturer for details. |
Thermal improvement | Consult manufacturer for details. |
Frame | |
Profile | Contemporary, 50 mm.Guidance for specification option: Clean lines, sleek flat frame, flush sash finish. |
Wood species | Pine from North-European species Pinus sylvestris. |
Chain of custody | FSC. |
Appearance class | Guidance for specification option:
|
Wood finishes | Manufacturer's standard.Guidance for specification option: Timber frame: Water-based diffusion open timber surface treatment system consisting of multiple layers.
|
Metal finishes | |
Coating | Polyester powder coated.Guidance for specification option: Aluminium (external): Polyester powder coat in compliance with BS EN 6496, BS EN 6497, & DIN 50939 with applicators to be registered under the European Qualicoat and/or GSB quality assurance schemes. |
Colour | Polyester powder-coated.Guidance for specification option: Polyester powder coated - RAL colours from the Classic K7 range, Granite, NCS range, consult manufacturer for options and insert requirements. Anodized, silver.Anodized, bronze.Clear lacquer.Guidance for specification option: Internal only. |
Film thickness (minimum) | 60–120 µm.Guidance for specification option: As required, unless the specific colour requires a thicker layer to cover completely. |
Ventilator | Standard trickle vent.Guidance for specification option: Externally concealed trickle ventilators will be incorporated into the framing sections. Ventilators are placed in the frame jamb or in the frame head. Site fitted acoustic vent.Not required. |
Glazing or infill | |
Standard | Relevant parts of BS EN 1279.Guidance for specification option: Various panel build ups available, consult manufacturer. |
Requirements | Double glazed.Guidance for specification option: 32 mm double glazing rebate; Insulated Glass Units (IGUs) and panels. |
Hardware | Not required.Factory fitted restrictor.Locking handle.Non-locking handle.Child restrictor handle.Click vent.Night vent position lock.Manufacturer guidanceNot applicable for fixed light. |
Operation | |
Type | Fixed.Side guided (for internal clean).Side hung.Top guided.Top swing fully reversible (for internal clean).Side swing (for internal clean). |
Fixing features | Manufacturer's standard.Guidance for specification option: Consult manufacturer for details. |
Country of material origin | Denmark |
Country of product manufacture | Poland |
Material | Wood Guidance for specification option: Timber frame internally
Aluminium Guidance for specification option: Aluminium cladding externally
Glass Guidance for specification option: Two choices of Insulating glass units: 32 mm or 52 mm. Toughened/ laminated glass where required, allowing for 6.8 mm laminate where secured by design is required. Insulating glass units conform to:
|
Platform | Compatible | Version |
---|---|---|
- | 1 |