Verified by manufacturer 2 months ago
FD90
Fire resisting doorset achieving either 90 or 120 minute rating.
Suitable as internal flush doorsets providing 90 minutes or 120 minutes fire resistance.
Shadbolt FD90 and FD120 are internal flush doorsets providing 90 minutes or 120 minutes fire resistance, fully tested and certificated. Supplied as factory-assembled doorsets only, to ensure fire performance.
Features and benefits:
Finish | Matt Guidance for specification option: Door leaf and frame. Gloss Guidance for specification option: Frame. Satin Guidance for specification option: Frame. Stained Guidance for specification option: Frame. |
Material | Wood Guidance for specification option: Wood veneer, hardwood, and plywood. Chipboard Glass Laminate Guidance for specification option: Plastic laminate. Medium density fibreboard (MDF) |
Shape | Rectangle |
Length | Bespoke |
Width | Bespoke Manufacturer guidanceMaximum size. |
Height | Bespoke Manufacturer guidanceMaximum size. |
Warranty description | One year |
Uniclass | |
CAWS | L20/410 Wood doorsets L20/55 Doorsets |
Product range |
Third-party certification | QA Certificate. |
Performance | |
Fire resistance | |
Integrity | To BS 476-22, 90 minutes. |
Strength and durability | To BS EN 1191, 1192 and 12400, Class 4.Guidance for specification option: Severe duty. Manufacturer guidanceMechanical performance |
Frame | |
Material | Hardwood.Guidance for specification option: 640 kg/m³ (minimum). |
Finish | Enamel satin lacquer.High gloss clear polyester.Semi-matt lacquer.Stain, colour.Guidance for specification option: Insert requirements. As door leaf.Manufacturer guidanceFinish as delivered. Consult manufacturer details of finishes that complement veneered doors. |
Door leaf | |
Thickness | 64 mm. |
Core | Timber-based core.Guidance for specification option: With non-combustible mineral fibre insulation sub-facings, enclosed in high quality hardwood stiles and rails, faced overall with MDF, plywood or chipboard. |
Facings | Plastic laminate, colour.Guidance for specification option: Alternative facing. Insert requirements. Wood veneer, species.Guidance for specification option: Insert requirements. Manufacturer guidanceConsult manufacturer available facings, details, and product references. |
Species | Manufacturer guidanceConsult manufacturer's available species. |
Lippings | Lip two vertical edges concealed.Lip two vertical edges exposed. |
Finish | Semi-matt lacquer.Guidance for specification option: For wood veneer facings. Two coats of high-solid acid-catalysed semi-matt (20% gloss). Semi-matt polyurethane lacquer.Guidance for specification option: For wood veneer facings. Two coats of high-solid acid-catalysed semi-matt (20% gloss). Semi-matt UV cured lacquer.Guidance for specification option: For wood veneer facings. Two coats of high-solid acid-catalysed semi-matt (20% gloss). Coloured plastic laminate.Guidance for specification option: For plastic laminate finish. Consult with manufacturer for exact details and product references. Manufacturer guidanceFinish as delivered |
Hardware | As schedule.Guidance for specification option: Insert requirements. |
Architraves | |
Material | Hardwood.Guidance for specification option: 640 kg/m³ (minimum). |
Glazed aperture | Not required. Clear laminated. Guidance for specification option: Insert thickness and style requirements. Clear toughened. Guidance for specification option: Insert thickness and style requirements. As drawing. Guidance for specification option: Insert requirements. |
Rounded vertical edges | Not required. Required. |
Contains Red List materials | No |
Country of material origin | Europe |
Country of product manufacture | United Kingdom |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 0.72 kg CO₂ eq/m³ Self declared |