Verified by manufacturer 5 months ago
Hermetically Sealed Double Glazed IGU (CWCT Class 2 Non-fragile)
BRE Certificate
Certificate type
ISO 9001 Quality Management
Certificate type
A self-supported, hinged flatglass rooflight with 24v electric operation.
Designed to be installed on all roof pitches and roof types. For applications in commercial, education, leisure and residential buildings.
A self-supported, hinged rooflight with safer 24v electric operation that is a solution for providing additional daylight and natural ventilation to living spaces. The frames are manufactured from extruded aluminium section to BS 1474, EN 12020-1:2001. Polyamide thermal breaks in lid and base frame to BS EN ISO 16396-2:2017 making the frames fully thermally broken and extremely thermally-efficient.
Features and benefits:
Designed to standard loadings of 640 N/m² (snow) and 750 N/m² (wind) and in accordance with the following Standards:
Color | Black Grey Other |
Finish | Powder-coated |
Material | Aluminium Glass |
Shape | Square Rectangle Triangle Hexagon Pentagon |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 15 year |
Uniclass | |
CAWS | L10/45 Rooflights L10/460 Rooflights |
Product range |
Form | Flat. |
Size | Manufacturer guidanceInsert requirements; shape specified separately below. |
Product performance | |
Fire performance | |
Reaction to fire | Euro Class A1 non-combustible. |
Whole window U-value | 0.4 W/m²K.Guidance for specification option: Lowest U-value achievable; consult manufacturer for project-specific values. |
Frame | |
Material | Extruded aluminium. |
Finish | |
Coating | Powder coating to BS EN 12206-1. |
Colour | Anthracite Grey (RAL 7016).Black (RAL 9005).White (RAL 9010).Bespoke RAL. |
Glazing or infill | |
Type | Insulating glass units, standard.Guidance for specification option: Double glazed. Insulating glass units, solar control.Insulating glass units, privacy glass.Insulating glass units, body tinted.Insulating glass units, acoustic laminate.Insulating glass units, coloured glass.Guidance for specification option: Insert colour requirements below. Insulating glass units, CUin advanced thermal performance.Insulating glass units, triple glazed.Insulating glass units, quadruple glazed.Insulating glass units, switchable private glass.Insulating glass units, heated anti-condensation glass.Insulating glass units, low iron glass. |
Colour | Clear.Other.Guidance for specification option: Insert requirements. Hundreds of options are possible through the use of Vanceva® coloured laminated interlayer(s); consult manufacturer for details. |
Coating | Standard.Easy-clean coating (Ritec). |
Operation | |
Type | Powered, electric, 24 V.Guidance for specification option: Standard. Powered, electric, 230 V. |
Control | 100 mm chain stroke.Guidance for specification option: Optional. 200 mm chain stroke.Guidance for specification option: Optional. 300 mm chain stroke.Guidance for specification option: Standard. 400 mm chain stroke.Guidance for specification option: Optional. 500 mm chain stroke.Guidance for specification option: Optional. Manufacturer guidance
|
Accessories | None.Integral blind within cavity of glass.Standard blind under glass connected to base frame or in lightwell.Paint or sandblast borders.Manifestation.Guidance for specification option: Artwork, company logo or other - insert requirements. |
Shape | Square. Rectangular. Circular. Elliptical. Triangular. |
Outer pane | 6 mm heat soaked toughened glass. |
Cavity space fill | 16 mm argon filled with Swisspacer warm edge spacer, silicone bonded. |
Inner pane | 9.5 mm laminated glass with PVB interlayer and polished edges. 10.8 mm laminated glass with PVB interlayer and polished edges. 11.5 mm laminated glass with SGP interlayer and polished edges. 13.5 mm laminated glass with SGP interlayer and polished edges. Manufacturer guidanceGeneral construction uses PVB laminate , though for Class 1 and 2 variants at certain sizes the PVB will be upgraded to SGP. Consult manufacturer for details. |
Snow load | 640 N/m². |
Wind load | 750 N/m². |
Contains Red List materials | No |
Country of material origin | France |
Country of product manufacture | United Kingdom |
Material | Aluminium Glass |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 0 kg CO₂ eq/kg Self declared |
Recyclability | Glass and aluminium are highly recycled. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 94 % |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |
Skyway AOV Hinged Flat Glass Smoke Vent Rooflight
Skyway Electric Access Flat Glass Rooflight
Skyway Fixed Flat Glass Rooflight - Multi Pane
Skyway Fixed Flat Glass Rooflight - Single Pane
Skyway Fixed Flat Glass Rooflight With Wall Abutment(s) - Multi Pane
Skyway Fixed Flat Glass Rooflight With Wall Abutment(s) - Single Pane
Skyway Fixed Protect+ Flat Glass Rooflight
Skyway Fixed Walk On Flat Glass Rooflight - Multi-Pane
Skyway Fixed Walk On Flat Glass Rooflight - Single Pane
Skyway Fixed Walk On Flat Glass Rooflight With Wall Abutment(s) - Multi-Pane