Verified by manufacturer 5 months ago
Bituminous warm flat roof system on a concrete substrate with PIR insulation and a partially self-adhered underlayer & torched on waterproofing layer.
For exposed roofs with a concrete substrate. For other uses and substrates, including use under a green roof, please see other listings or contact Soprema UK.
A warm roof system with a cap sheet composed of styrene-butadiene-styrene (SBS) modified bitumen with composite polyester reinforcement. The upper surface is finished with granules and the overlap is protected by a thermofusible film. The lower surface is protected by macro-perforated thermofusible film and talcum/sand for use within a single or multi layer waterproofing system.
An underlayer with a vapour-pressure and tension dispersion system, composed of elastomer-modified bitumen and a composite polyester reinforcement. PIR insulation faced with a polypropylene fleece-finished bitumen glass working surface and a mineral glass facing to the under side and a self-adhesive AVCL applied to a primed deck.
Features and benefits:
Color | Black Guidance for specification option: Black, mixed brown. Brown Guidance for specification option: Black, mixed brown. |
Finish | Mineral granules Guidance for specification option: Upper side, thermofusible film overlap protection. Sanded/ talcum Guidance for specification option: Lower side, thermofusible film with sand / talcum finish. Thermofusible film |
Material | Styrene-butadiene-styrene (SBS) modified bitumen Polyisocyanurate Polyester Polypropylene |
Length | 8000 mm |
Width | 1000 mm |
Warranty description | 30 years |
Uniclass | |
CAWS | J41/10 Reinforced bitumen membrane warm deck roof covering J41/110 Built-up reinforced bitumen membrane warm deck roof covering J41/115 Single-layer reinforced bitumen membrane warm deck roof covering J41/12 Reinforced bitumen membrane cold deck roof covering J41/120 Built-up reinforced bitumen membrane inverted roof covering J41/125 Single-layer reinforced bitumen membrane inverted roof covering J41/130 Built-up reinforced bitumen membrane cold deck roof covering J41/135 Single-layer reinforced bitumen membrane cold deck roof covering J41/400 Built-up reinforced bitumen waterproof covering J41/405 Single-layer reinforced bitumen waterproof covering |
Product range |
Standard | To BS EN 13707. |
Performance characteristics | See product Technical Datasheet. |
Material | |
Carrier material | Polyester. |
Bitumen modification | Elastomeric. |
Thickness (minimum) | 5 mm. |
Weight (minimum) | 5.8 kg/m². |
Surface finish | |
Top | Mineral granules and thermofusible film. |
Underside | Macro perforated thermofusible film and sand/ talcum. |
Colour | Black.Brown. |
Third-party certification | BBA certificate 95/3098. |
Tensile strength (to BS EN 12311-1) | Longitudinal, 1300 N/50mm / Transverse, 1000 N/50mm. |
Elongation at break (to BS EN 12311-1) | 35%. |
Dimensional stability | 0.3%. |
Tear resistance (to BS EN 12310-1) | 275 N. |
Flexibility at low temperature | -30°C. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 3 | |
- | 1 |