Verified by manufacturer 11 months ago
SPB100/100
Fire stopping between party wall blockwork and spandrel panel.
For sealing the top of the party wall cavity between blockwork and spandrel panel.
Spandrel barrier designed to be fitted across the top of party wall blockwork underneath a timber spandrel panel. Installation is easy: the barrier simply push-fits into the top of the party wall cavity. The spandrel panel then drops on top, compressing the barrier and creating a fire and thermal break between the spandrel panel and blockwork. Lengths should be butted tightly together, with care taken to ensure that no gaps remain.
It seals the top of the party wall cavity, allowing a zero U-value to be achieved when used in conjunction with ARC T-Barrier® vertically. The barrier is compressed between the top of the party wall blockwork and underside of the spandrel panel, creating a fire and thermal break.
Features and benefits:
Color | Orange |
Material | Rock fibre mineral wool |
Length | 1200 mm |
Uniclass | |
CAWS | F30/18 Cavity closers F30/180 Cavity closers |
Fire performance | To BS EN 13501-1, Euroclass A1. |
Materials | Rock fibre mineral wool. |
ThermalConductivity | 0.037 W/mK. |
Cavity width |
|
Dimensions | 120/100 x 25/200 x 1200 mm. |
Cavity Stop Sock
Fire Stop Slab - Smoke and Cavity barrier for masonry
Fire Stop Strip - Fire-rated void filler for masonry
Flexi-Closer - Thermal closer for window/ door reveals
Insulated DPC - Thermal cavity closer
Open State Cavity Barrier (OSCB) - Ventilated cavity barrier
Party Wall DPC - Cavity Barrier for Masonry Wall Junction
Rockfibre Insulated DPC - Fire-Rated Cavity Closer Window and Door
Soffit Slab - Mineral Wool fire stopping in the soffit
T-Barrier For Masonry