NBS Source
I'm a manufacturer
Compare variants

SPEEDLINE Single Frame Partition Systems Utilising Knauf Fire Panel

Verified by manufacturer 3 months ago

50-K-55

Metsec (voestalpine Metsec) Variant:
Third party certifications:
  • BSI Kitemark

    BSI Kitemark

    Certificate type

  • EPD

    EPD

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • UK Conformity Assessed (UKCA)

    UK Conformity Assessed (UKCA)

    Certificate type

An economical friction-fit system to assemble frames for strong, compact and lightweight non-load‑bearing partition.

Jump to:
+44 (0) 121 601 6000 Website

Application

Sectors:

  • Residential.
  • Offices.
  • Healthcare.
  • Education.
  • Commercial.
  • Retail.
  • RMI.
  • Student Accommodation.


Description

An economical friction-fit system to assemble frames for strong, compact, lightweight non-load‑bearing partitions, Speedline Partitioning Systems are ideal for use in domestic and commercial situation.


Features and benefits:

  • Quick to erect, lightweight and clean.
  • Metal stud is dimensionally accurate and will not twist or bow.
  • Range of stud widths – 50, 70, 92 and 146 mm to meet different performance requirements.
  • Services are easy to install.
  • Acoustic insulation can easily be installed to uprate sound insulation.
  • Easy to cut to length using tin snips.
  • Frames easily fit together.
  • Door frames simply formed.
  • Range of UKAS accredited tests available for Fire (30-120 mins.) and Acoustics (37-60 dB).


Structural performance:

  • Strength grade to BS 5234-2:1992 Annexes A-F.

Fire performance:

  • Fire resistance to BS 476:1987:Part 22.

Acoustic performance:

  • Calculated weighted sound reduction index (Rw) to BS EN ISO 10140-2: 2010.

Installing framing for partitions:

  • Partition height (maximum) calculated based on a limiting deflection of L/240 at 200 Pascals.

General information

Length

Bespoke

Width

77 mm

82 mm

97 mm

102 mm

112 mm

Show more

Height

Bespoke

Uniclass

Ss_25_10_30_35 Gypsum board partition systemsPrimary

CAWS

K10/30 Metal stud

K10/125 Metal stud partition system

Product range

Drylining / Single Frame Partitions - C Stud
Drylining / SPEEDLINE Drywall Systems

Specification data - Gypsum board partition systems

Framing

Speedline 'C' Stud, 50 mm.

Linings

-

Outer layers

Knauf Fire Panel, 12.5 mm.

Joint treatment

Speedline Drywall Fibreglass Tape.

Speedline Ready Mix Joint Compound.

Speedline Corner Bead Tape.

System accessories

Speedline Fire Rated Acoustic Sealant.

SpeedlinePB24 Partition Brace.

Speedline FS24 Flat Bracing Strip.

Speedline Service Support Plate.

Speedline Putty Pads.

Fire resistance

To BS 476-22:1987, 30/ 30 minutes (Integrity/ Insulation).

Partition height

Guidance for specification option:

Insert requirement based on centres specified.

  • 600 mm centres: maximum 2500 mm.
  • 400 mm centres: maximum 2800 mm.
  • 300 mm centres: maximum 2900 mm.

Calculated based on a limiting deflection of L/240 at 200 Pascals.

Nominal thickness

77 mm.

Manufacturer guidance

Optimum system thickness.

Note that if a greater partition thickness is required, this may improve the sound reduction index (Rw) - consult manufacturer for details.

Centres

600 mm.

Guidance for specification option:

Allows for greater maximum partition heights.

400 mm.

Guidance for specification option:

Allows for greater maximum partition heights.

300 mm.

Guidance for specification option:

Standard.

StrengthGrade

Medium duty.

Head/ Floor channel

Speedline Standard Track.

Guidance for specification option:

Used for partition heights under 4 m.

Available in 50, 52, 62 or 72 mm wide.

25 mm flange.

Speedline 32 mm Leg Track.

Guidance for specification option:

Used for partition heights under 4 m.

Available in 52, 62, 72, 94 or 148 mm wide.

32 mm flange.

Speedline Deep Track.

Guidance for specification option:

Used for partition heights between 4m and 8m.

Can be used as a head track where a deflection head of up to 30 mm is needed.

Available in 52, 62, 72, 94 or 148 mm wide.

50 mm flange.

Speedline Extra Deep Track.

Guidance for specification option:

Used for partition heights between 8m and 10.2 m.

Can be used as a head track where a deflection head of up to 45mm is needed.

Available in 72, 94 or 148 mm wide.

70 mm flange.

Sustainability data

Third party certifications

Third party certifications

BSI Kitemark

BSI Kitemark

BIM Level 2 Kitemark - For Design and Construction Phase

BSI Kitemark

BSI Kitemark

BSI Kitemark™ for BIM Objects

EPD

EPD

Environmental Product Declaration EPD - Drylining

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001:2015 Quality Management System

UK Conformity Assessed (UKCA)

UK Conformity Assessed (UKCA)

UKCA Declarations of Performance - Drylining

Literature

SPEEDLINE Fixings and Finishing Solutions

SPEEDLINE Fixings and Finishing Solutions

SPEEDLINE Partitioning Systems

SPEEDLINE Partitioning Systems

Product Data Sheet - Drylining

Product Data Sheet - Drylining