Verified by manufacturer 4 months ago
TWC50-S-60(2x50)(210)
BSI Kitemark
Certificate type
EPD
Certificate type
ISO 9001 Quality Management
Certificate type
UK Conformity Assessed (UKCA)
Certificate type
Plasterboard partition system.
Wall partitions.
Speedline range of twin frames partitions are available in three options:
Separating walls in residential applications, partitions between noisy rooms in commercial, healthcare or education buildings require wall build ups with high levels of acoustic insulation. Bracing 'C' studs every 1200 mm vertically.
Features and benefits:
Structural performance:
Fire performance:
Acoustic performance:
Installing framing for partitions:
Length | Bespoke |
Width | 200 mm 210 mm 250 mm |
Height | Bespoke |
Uniclass | |
CAWS | K10/30 Metal stud K10/125 Metal stud partition system |
Product range |
Framing | Twin Speedline 'C' Stud, braced, 50 mm. |
Insulation | Acoustic partition roll, 50+50 mm. |
Linings | |
Inner layers | Siniat GTEC dB Board, 15 mm. |
Outer layers | Siniat GTEC dB Board, 15 mm. |
Fasteners | Speedline Drywall Screws. |
Joint treatment | Speedline Drywall Fibreglass Tape.Speedline Ready Mix Joint Compound.Speedline Corner Bead Tape. |
System accessories | Speedline Fire Rated Acoustic Sealant.Speedline PB24 Partition Brace.Speedline FS24 Flat Bracing Strip.Speedline Service Support Plate.Speedline Putty Pads. |
Fire resistance | To BS 476-22:1987, 90/ 90 minutes (Integrity/ Insulation). |
Partition height | Manufacturer guidanceInsert requirement, maximum 6200 mm (at 600 mm centres). Calculated based on a limiting deflection of L/240 at 200 Pascals. |
Nominal thickness | 210 mm. Guidance for specification option: Optimum system thickness. Note that if a greater partition thickness is required, this may improve the sound reduction index (Rw) - consult manufacturer for details. |
Calculated weighted sound reduction index (Rw) | 60 (-9) Rw dB. Guidance for specification option: Based on the nominal system thickness. |
Centres | 600 mm. |
StrengthGrade | Severe duty. |
Head/ Floor channel | Speedline Standard Track. Guidance for specification option: Used for partition heights under 4 m. Available in 50, 52, 62 or 72 mm wide. 25 mm flange. Speedline 32 mm Leg Track. Guidance for specification option: Used for partition heights under 4 m. Available in 52, 62, 72, 94 or 148 mm wide. 32 mm flange. Speedline Deep Track. Guidance for specification option: Used for partition heights between 4m and 8m. Can be used as a head track where a deflection head of up to 30 mm is needed. Available in 52, 62, 72, 94 or 148 mm wide. 50 mm flange. Speedline Extra Deep Track. Guidance for specification option: Used for partition heights between 8m and 10.2 m. Can be used as a head track where a deflection head of up to 45mm is needed. Available in 72, 94 or 148 mm wide. 70 mm flange. |
Standards | To BS 5234-2:1992 Annexes A-F, BS 476:1987:Part 22, BS EN ISO 10140-2: 2010. |
BSI Kitemark
BIM Level 2 Kitemark - For Design and Construction Phase
BSI Kitemark
BSI Kitemark™ for BIM Objects
EPD
Environmental Product Declaration EPD - Drylining
ISO 9001 Quality Management
ISO 9001:2015 Quality Management System
UK Conformity Assessed (UKCA)
UKCA Declarations of Performance - Drylining
SPEEDLINE Shaft Encasement Systems Utilising British Gypsum Board
SPEEDLINE Shaft Encasement Systems Utilising Knauf Board
SPEEDLINE Shaft Encasement Systems Utilising Siniat Board
SPEEDLINE Single Frame Acoustic Stud Partition Systems Utilising British Gypsum Board
SPEEDLINE Single Frame Acoustic Stud Partition Systems Utilising Knauf Board
SPEEDLINE Single Frame Acoustic Stud Partition Systems Utilising Siniat Board
SPEEDLINE Single Frame Partition Systems Utilising British Gypsum Duraline
SPEEDLINE Single Frame Partition Systems Utilising British Gypsum FireLine
SPEEDLINE Single Frame Partition Systems Utilising British Gypsum SoundBloc
SPEEDLINE Single Frame Partition Systems Utilising British Gypsum WallBoard