NBS Source
I'm a manufacturer
Compare variants

SPEEDLINE Twin Frame I Stud Partition Systems Utilising Knauf Board

Verified by manufacturer 3 months ago

TWI50-K-59(2x50+100)(250)

Metsec (voestalpine Metsec) Variant:
Third party certifications:
  • BSI Kitemark

    BSI Kitemark

    Certificate type

  • EPD

    EPD

    Certificate type

  • ISO 9001 Quality Management

    Certificate type

  • UK Conformity Assessed (UKCA)

    UK Conformity Assessed (UKCA)

    Certificate type

Plasterboard partition system

Jump to:
+44 (0) 121 601 6000 Website

Application

Wall partitions.

Description

Lightweight, quick to construct, cost-effective, compact and able to achieve high levels of fire resistance and sound insulation. The non-load bearing high performance walls, constructed from plasterboard facings on metal studs, offer considerable advantages over traditional heavy masonry construction.


Features and benefits:

  • Acoustics up to 70 Rw dB with Ctr of -10.
  • Suitable for use with Code for Sustainable Homes or BREEAM.
  • Suitable for party wall construction with requirements of +3 to +8 dB DnT,w on ADE requirements of 45 DnT,w + Ctr.
  • Fire resistance up to 120 mins BS 476:Part 22.
  • Structural columns can be incorporated within the partition cavity due to unbraced twin frame design.


Structural performance:

  • Strength grade to BS 5234-2:1992 Annexes A-F.

Fire performance:

  • Fire resistance to BS 476:1987:Part 22.

Acoustic performance:

  • Calculated weighted sound reduction index (Rw) to BS EN ISO 10140-2: 2010.

Installing framing for partitions:

  • Partition height (maximum) calculated based on a limiting deflection of L/240 at 200 Pascals.

General information

Length

Bespoke

Width

200 mm

210 mm

250 mm

260 mm

270 mm

Show more

Height

Bespoke

Uniclass

Ss_25_10_30_35 Gypsum board partition systemsPrimary

CAWS

K10/30 Metal stud

K10/125 Metal stud partition system

Product range

Drylining / Twin Frame Partitions - Unbraced I Stud
Drylining / SPEEDLINE Drywall Systems

Specification data - Gypsum board partition systems

Framing

Twin Speedline 'I' Stud, 50 mm.

Insulation

Acoustic partition roll, 50+50+100 mm.

Linings

-

Inner layers

Knauf Soundshield Plus, 12.5 mm.

Outer layers

Knauf Soundshield Plus, 12.5 mm.

Fasteners

Speedline Drywall Screws.

Joint treatment

Speedline Drywall Fibreglass Tape.

Speedline Ready Mix Joint Compound.

Speedline Corner Bead Tape.

System accessories

Speedline Fire Rated Acoustic Sealant.

Speedline PB24 Partition Brace.

Speedline FS24 Flat Bracing Strip.

Speedline Service Support Plate.

Speedline Putty Pads.

Fire resistance

To BS 476:1987:Part 22, 60/ 60 minutes (Integrity/ Insulation).

Partition height

Guidance for specification option:

Insert requirement based on centres specified.

  • 600 mm centres: maximum 2700 mm.
  • 400 mm centres: maximum 3300 mm.

Calculated based on a limiting deflection of L/240 at 200 Pascals.

Nominal thickness

250 mm.

Guidance for specification option:

Optimum system thickness.

Note that if a greater partition thickness is required, this may improve the sound reduction index (Rw) - consult manufacturer for details.

Calculated weighted sound reduction index (Rw)

70 (-2;-8) Rw dB.

Guidance for specification option:

Based on the nominal system thickness.

Centres

600 mm.

Guidance for specification option:

Standard.

400 mm.

StrengthGrade

Severe duty.

Head/ Floor channel

Speedline Standard Track.

Guidance for specification option:

Used for partition heights under 4 m.

Available in 50, 52, 62 or 72 mm wide.

25 mm flange.

Speedline 32 mm Leg Track.

Guidance for specification option:

Used for partition heights under 4 m.

Available in 52, 62, 72, 94 or 148 mm wide.

32 mm flange.

Speedline Deep Track.

Guidance for specification option:

Used for partition heights between 4m and 8m.

Can be used as a head track where a deflection head of up to 30 mm is needed.

Available in 52, 62, 72, 94 or 148 mm wide.

50 mm flange.

Speedline Extra Deep Track.

Guidance for specification option:

Used for partition heights between 8m and 10.2 m.

Can be used as a head track where a deflection head of up to 45mm is needed.

Available in 72, 94 or 148 mm wide.

70 mm flange.

Standards

To BS 5234-2:1992 Annexes A-F, BS 476:1987:Part 22, BS EN ISO 10140-2: 2010.

Sustainability data

Country of product manufacture

United Kingdom

Third party certifications

Third party certifications

BSI Kitemark

BSI Kitemark

BIM Level 2 Kitemark - For Design and Construction Phase

BSI Kitemark

BSI Kitemark

BSI Kitemark™ for BIM Objects

EPD

EPD

Environmental Product Declaration EPD - Drylining

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001:2015 Quality Management System

UK Conformity Assessed (UKCA)

UK Conformity Assessed (UKCA)

UKCA Declarations of Performance - Drylining

Literature

SPEEDLINE Partitioning Systems

SPEEDLINE Partitioning Systems

SPEEDLINE Fixings and Finishing Solutions

SPEEDLINE Fixings and Finishing Solutions

Product Data Sheet - Drylining

Product Data Sheet - Drylining

Similar products from Metsec (voestalpine Metsec)

SPEEDLINE Shaft Encasement Systems Utilising British Gypsum Board

SPEEDLINE Shaft Encasement Systems Utilising British Gypsum Board

SPEEDLINE Shaft Encasement Systems Utilising Knauf Board

SPEEDLINE Shaft Encasement Systems Utilising Knauf Board

SPEEDLINE Shaft Encasement Systems Utilising Siniat Board

SPEEDLINE Shaft Encasement Systems Utilising Siniat Board

SPEEDLINE Single Frame Acoustic Stud Partition Systems Utilising British Gypsum Board

SPEEDLINE Single Frame Acoustic Stud Partition Systems Utilising British Gypsum Board

SPEEDLINE Single Frame Acoustic Stud Partition Systems Utilising Knauf Board

SPEEDLINE Single Frame Acoustic Stud Partition Systems Utilising Knauf Board

SPEEDLINE Single Frame Acoustic Stud Partition Systems Utilising Siniat Board

SPEEDLINE Single Frame Acoustic Stud Partition Systems Utilising Siniat Board

SPEEDLINE Single Frame Partition Systems Utilising British Gypsum Duraline

SPEEDLINE Single Frame Partition Systems Utilising British Gypsum Duraline

SPEEDLINE Single Frame Partition Systems Utilising British Gypsum FireLine

SPEEDLINE Single Frame Partition Systems Utilising British Gypsum FireLine

SPEEDLINE Single Frame Partition Systems Utilising British Gypsum SoundBloc

SPEEDLINE Single Frame Partition Systems Utilising British Gypsum SoundBloc

SPEEDLINE Single Frame Partition Systems Utilising British Gypsum WallBoard

SPEEDLINE Single Frame Partition Systems Utilising British Gypsum WallBoard